Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
Table for working with powder samples
Table for working with powder samples
A table with a stone countertop and a stainless steel sheet located in the center with a perforation through which exhaust ventilation creates a constant flow of air carrying away sample particles
Produced in: Novosibirsk
Alpha-beta radiometer for measuring small activities UMF-2000
Alpha-beta radiometer for measuring small activities UMF-2000
A low-background alpha-beta radiometer with a silicon detector, widely used for measuring small activities. It is recommended for measuring the total alpha and beta activity of natural and drinking waters, as well as for measuring the activity of alpha-emitting radionuclides by spectrometric method. Purpose: measurement of the total activity of alpha-emitting nuclides in "thick" and "thin" counting samples of environmental objects; measurement of the total activity of beta-emitting nuclides in counting samples of soil samples, water samples, air filters and samples obtained by selective radiochemical extraction; measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by radiometric method (if available); measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by the spectrometric method (if there are techniques and a set of spectrometric "UMF - Spectrum").
Doza
Zelenograd
Produced in: Moscow
Anemorumbometer Vetromer-1
Anemorumbometer Vetromer-1
from 208 548 ₽
Wind speed range: 0.7 – 55.0 m/s Direction range: 0 – 360° Accuracy Characteristics: Speed: PG±(0.3+0.05)m/s Direction: ±3° Power supply: AC 50 Hz 220 V (187-242 V) DC power supply 12±3 V Power consumption is 7 VA, 15 VA with heating turned on. Interface: Remote sensor: RS-485 (possibility of operation of one remote control with several sensors) or (on request) a current loop. Remote computer: USB or RS-232. By order: current loop – distance up to 10 km modem – remoteness is determined by the customer's requirements. Operating conditions: sensor – from -55C to +50C; measuring console and power supply – from +10C to +40C.
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
High-frequency signal generator G4-227
High-frequency signal generator G4-227
The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 9 kHz to 6 GHz Frequency tuning discreteness of 1 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 10 to 13 dBm The basic error of setting the reference power level is ± (0.5 – 1.0) dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the main error of the frequency deviation setting is ± (20 – 25)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient ± (0.25 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 300 ns to 20 s - the range of the modulating pulse repetition period from 340 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 200 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 13 kg
Produced in: Moscow
Rubidium frequency standard H1-1012
Rubidium frequency standard H1-1012
The Ch1-1012 frequency standard is designed for mobile applications with high requirements for dimensions, weight and power consumption as an embedded signal source of high stability in frequency measuring devices and complexes, telecommunication systems, navigation and communication systems. This device can serve as a promising substitute for quartz generators in the development of high-resolution equipment, where the accuracy characteristics of a quartz generator are no longer sufficient.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Mobile radiometric installation UDI-2
Mobile radiometric installation UDI-2
Designed for monitoring radionuclide I-131 in the surface air of the industrial site, sanitary protection zone and monitoring zone of nuclear power plants.
Doza
Zelenograd
Produced in: Moscow
ZVpP-100 Pneumatic Vacuum Shutter
ZVpP-100 Pneumatic Vacuum Shutter
The ZVpP-100 vacuum valve with pneumatic actuator equipped with 100mm conditional passages is designed to overlap vacuum systems in the pressure range from 1x10-6 to 1,07x105 Pa (from 0,75x10-8 to 800 mm Hg). The ZVpP-100 vacuum pneumatic shutter is manufactured in the climatic version of the UHL placement category 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69. The working environment is air and non–aggressive gases. The temperature of the working environment is from plus 1°C to plus 40°C. The vacuum valve with a pneumatic actuator is not intended for use in fire and explosive hazardous industries. The ZVpP-100 vacuum pneumatic shutter consists of a mechanism, a housing and a pneumatic actuator. The pneumatic actuator includes a pneumatic cylinder, on the piston of which a permanent magnet is installed to determine its position by means of magnetic position sensors "Closed" and "Open" fixed on the cylinder body and a distributor into which compressed air is supplied through a fitting. The speed of the pneumatic cylinder in particular and the operation of the shutter as a whole are regulated by rotating the pneumatic throttle head, if the pneumatic throttle heads are fully tightened, then the speed of opening and closing the shutter will be maximum. The solenoid, powered by a connector, serves as a distributor control device and is applicable in standard production conditions where the relative humidity of the air is not higher than 75%.
Produced in: Kazan
2ZVE-250R Electromechanical vacuum shutter with gearbox
2ZVE-250R Electromechanical vacuum shutter with gearbox
The 2ZVE-250R vacuum shutter with electromechanical drive equipped with 250mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75x10–8 to 800 mm Hg). The 2ZVE-250R shutter is pendulum-type. The 23VE-250R shutter is manufactured in the climatic version UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air and non–aggressive gases. It is not intended for use in fire and explosive hazardous industries. The 23VE-250R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, the gate belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Metolab 100 Rockwell Hardness Tester
Metolab 100 Rockwell Hardness Tester
METOLAB 100 is an analog stationary hardness tester with manual loading, designed to measure the hardness of various materials according to the Rockwell method, HRA, HRB and HRC scales, in accordance with current standards, equipped with an analog clock–type indicator. Structurally, the METOLAB 100 hardness tester is a stationary device consisting of a load application mechanism and the measuring unit itself. The principle of operation of the device is based on the indentation of a diamond cone or steel ball tip into the material under study, followed by measurement of the resulting print. Due to its ease of operation, the stationary METOLAB 100 hardness tester can find its application in a wide variety of industries and production, as well as in educational institutions of various levels in the training of specialists. The stationary METOLAB 100 Rockwell hardness tester is included in the State Register of Measuring Instruments of Russia (GRSI) and comes with a certificate of primary verification (on request). The number in the GRSI is 65128-16. Distinctive features of the stationary METOLAB 100 Rockwell hardness tester: Simple and convenient both in operation and maintenance; Wide range of measured values; High degree of reliability due to the absence of electronic components in the design of the hardness tester; The device operates without power. Basic delivery package: Stationary METOLAB 100 hardness tester; Indenter with a ball (1.5875 mm) - 1 pc.; Conical diamond indenter (120°) - 1 pc.; Flat table SP1 (60 mm); V-shaped prismatic table SRP1 (40 mm); Rockwell hardness measures - 1 set; User Manual. Additional information: GOST standards and regulatory documents establishing requirements for the METOLAB 100 Rockwell hardness tester: GOST 8.064-94 GSI. State verification scheme for hardness measuring instruments on the Rockwell and Super-Rockwell scales; GOST 9013-59 Metals and alloys. Rockwell hardness measurement method. Scales A, B, C; GOST 22975-78 Metals and alloys. Rockwell hardness measurement method at low loads (Super-Rockwell); GOST 23677-79 Hardness testers for metals. General technical requirements.
Metolab
Moscow
Produced in: Moscow