Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for continuous automatic monitoring of the concentration of radioactive aerosols in autonomous mode or as part of automatic radiation monitoring systems in the air of working rooms and ventilation systems. Purpose: measurement of the volumetric activity of alpha-emitting radionuclides and beta-emitting radionuclides contained in the form of aerosols in the air.
Doza
Zelenograd
Produced in: Moscow
Flowmeter-counter ultrasonic Oriole
Flowmeter-counter ultrasonic Oriole
from 200 000 ₽
The ultrasonic Oriole flow meter is designed to measure the volumetric flow rate and volume of liquid in pressure pipelines. The measured medium can be any homogeneous isotropic liquid of various densities, including: clean cold and hot water supply and heating systems (up to +160 °C); natural water is clean and of a low degree of pollution; wastewater of low and medium degree of contamination; chemical solutions of acids, alkalis and other chemically aggressive media; mineral, synthetic and semi-synthetic machine oils; food products (vegetable oil, juices, syrups, vodka, ketchups, dairy products, etc.). Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Mortise, contactless overhead outside and full-bore primary converters embedded in the process allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
Designed to control the pressure and flow rate of non-aggressive gases in the lines of chromatographic and other analytical equipment. The measurement of gas flow is based on the conversion of the mass flow rate of gas into an electrical signal by the calorimetric method. The measured gas flow and pressure are displayed on a digital indicator. The device has an external RS485 interface, operating under the MODBUS RTU protocol. technical specifications: - gas flow measurement range – from 1 to 750 ml/min; - pressure measurement range from 0 to 0.4 MPa; - gas flow measurement error – no more than ± 2% in the measurement range of 100 art. ml / min; no more than 3% in the measurement range of 100 ... 750 art. ml / min; - measurement error suppression – no more than ± 0.25 %; - measured gases: Air, Nitrogen, Hydrogen, Helium, Argon, Methane; - the presence of a function for monitoring the volume of pumped gas for a given period of time; - the presence of a function for monitoring changes in gas pressure for a given period of time;- the device is powered from an external power source + 15V (an adapter for operation from a 220V 50Hz network is included in the delivery package).
Produced in: Yoshkar-Ola, Mari El
Reflection prefix PO-15 V
Reflection prefix PO-15 V
Designed for the study of various types of solid samples, including optical and semiconductor materials, precious stones and other objects of arbitrary shape • The sample is located on the subject plane of the investigated surface downwards, the angle of incidence of the central beam on the sample is 15 ° • Allows you to examine samples of small sizes (the diameter of the test area is from 1 mm) • The set-top box is equipped with a set of replaceable diaphragm holders for samples of different sizes • When using a mini-press, it allows you to examine samples in the form of a thin layer rolled out on a mirror plate made of alloy steel (radiation passes through the substance layer twice, reflecting from the mirror surface) • Not used: for the study of bulk and liquid substances
SIMEKS
Novosibirsk
Produced in: Novosibirsk
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
Rapid assessment of surface contamination with alpha-active radionuclides, in particular, polonium-210. The device is easy to operate, suitable for use by personnel of any qualification, including at home. ▪ Scintillation detector ▪ Silicon photoelectronic multiplier ▪ High sensitivity ▪ Light and sound indication when registering alpha particles ▪ Long-term operation without recharging ▪ 1" OLED colour screen
Produced in: Belarus, Minsk
High-frequency signal generator G4-235, G4-236
High-frequency signal generator G4-235, G4-236
Created on the basis of the G4-230 generator. Remote frequency converters extend the frequency ranges up to 53.57 GHz (G4-235) and up to 78.33 GHz (G4-236). The generators are capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz Frequency range at the output of the frequency converter (G4-235) from 37.5 to 53.57 GHz The frequency range at the output of the frequency converter (G4-236) is from 53.57 to 78.33 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter (G4-235) is from 0 to 13 dBm The range of setting the signal power level at the output of the frequency converter (G4-236) from 0 to 10 dBm The basic error of setting the reference power level is ± (1.0 – 2.5) dB Metrological characteristics of the generator in FM operation mode: - frequency range of the modulating signal from 1 Hz to 20 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 1 Hz to 200 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from 5°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
Produced in: Moscow
 VD-41P Eddy Current Flaw Detector
VD-41P Eddy Current Flaw Detector
Scope of application The VD-41P eddy current flaw detector is designed to work as part of automated quality control lines at pipe-rolling and metal-rolling enterprises with continuous output control of products together with other auxiliary devices: a paint meter, a path sensor, an object presence sensor, an automatic sorter, a demagnetizer. The device can also be used for input control at machine-building enterprises of the automotive, aviation, oil and gas, and agricultural industries. Technical specifications: Control frequencies: 1.0 – 100 kHz. Control speed (line speed): 0.5 - 5 m/s. The high-frequency filter is automatically adjustable depending on the speed. Signal phase adjustment: 0 - 359° . Converter current adjustment: 50 – 500mA. Automatic monitoring of the operability of the measuring converter. Data processing: - Software adjustable filter. - Signal evaluation using signal masks: - circular mask, - sector masks. - Sorting by control results. Display: 10.2” (26 cm) touch LCD (800x600). Operating system used: WINDOWS® 7. Dialog language: Russian, other languages (optional). Applicable eddy current converters: overhead type, through type, sector type. Interfaces: - Connector for the converter unit. - External automation control connector. - 4 outputs with delay adjustment - "dry contact". - 2 external information inputs. - VGA interface for connecting an external monitor. - USB 2.0. - Network: Ethernet (TCP/IP). - Other interfaces on special order. Power supply: 220 V, 50 Hz. Operating temperature range: 0 to +40°C. Type of climatic performance - UHL 4 (i.e. for moderate and cold climate). Enclosure protection degree: IP 53. Dimensions, w/h/d: 471 x 285 x 460 mm / can be built in a 19” rack/cabinet. Weight: approx. 20 kg.
Produced in: Moscow
General purpose exhaust cabinet LAB-PRO SHV 150.84.230 TR
General purpose exhaust cabinet LAB-PRO SHV 150.84.230 TR
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (22W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the back panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel – metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Radiation monitoring system "Frigate"
Radiation monitoring system "Frigate"
A simple and inexpensive radiation monitoring system for radiation-hazardous facilities, such as radionuclide source storages, isotope warehouses, clinical radionuclide diagnostics and therapy departments, PET centers, metrological laboratories where work with ionizing radiation sources is carried out, etc.
Doza
Zelenograd
Produced in: Moscow
Pulse DC power supply B5-71/5-PRO
Pulse DC power supply B5-71/5-PRO
1 supp.
Regulated switching power supplies with highly stable output characteristics Digital display of set and actual value, voltage and current (4 digits, LED) Electronic load switching on/off Protection against overload, short circuit, overheating and reverse polarity Low ripple output voltage less than 2mV Low ripple output current less than 5mA Minimum discreteness of setting output voltage and current 0.007/0.005 Operating modes: stabilization U and I, dynamic load RS-232 interface
DIPAUL
Saint Petersburg
Produced in: Saint Petersburg
Smart air probe L=150 mm SSV.150P with built-in flash memory
Smart air probe L=150 mm SSV.150P with built-in flash memory
from 12 351 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=150 mm SSV.150P with built-in flash memory is designed to measure the temperature of various media by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.150P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
 Electronic Stopwatch-Meter IVPR-53SCH
Electronic Stopwatch-Meter IVPR-53SCH
from 40 940 ₽
The electronic stopwatch - time parameter meter IVPR-53SCH is a panel device for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny