Search

11 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 8
    Applying
  • Names
  • 2
    Manufacturer
  • 1
    Made in
  • 5
    Additional
View:
11 products
Field strength meter small-sized microprocessor IPM-101M
Field strength meter small-sized microprocessor IPM-101M
Purpose: The device is designed to monitor compliance with the maximum permissible levels of high-frequency radiation (alternating electric field strength, alternating magnetic field strength and electromagnetic field energy flux density) at the workplaces of personnel servicing electrical and radio engineering installations and systems emitting an electromagnetic field, in accordance with GOST 12.1.006, GN 2.1.8./2.2.4.019 and San-PiN 2.2.4/2.1.8.055.
Doza
Zelenograd
Produced in: Moscow
MX-10 Magnetometer
MX-10 Magnetometer
from 67 000 ₽
The MX-10 magnetometer is an auxiliary tool for conducting magnetic powder control using permanent magnets, rectified current electromagnets by the applied field method, as well as for monitoring by the residual magnetization method according to the requirements of the current regulatory documentation. The MX-10 magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities, etc. Magnetometer MX-10 is an electronic measuring unit with a remote measuring converter, which is based on the Hall effect. The design of the device allows measuring both the normal and tangential component of the magnetic induction vector directly on the surface of the part. The measured value of the magnetic field induction value is displayed on the digital indicator of the electronic unit. Features and Benefits The updated version of the MX-10 magnetometer has a modern element base, which has significantly improved its performance, reduced error and expanded the measurement range (see the Table of Technical characteristics). The device is capable of operating in two modes: Constant measurement mode. This is convenient when carrying out a large number of measurements over a short period of time. Automatic shutdown mode 1 minute after measurement. It allows you to save the charge of the device, which is especially important in the field. A thermal compensation circuit ensures stable measurement readings at any temperature change. Other features include: The small dimensions of the Hall measuring transducer for the MX-10 magnetometer make it possible to measure the induction of the magnetic field in grooves, grooves, angular transitions, i.e. in those areas of the controlled product that are stress concentrators and are most dangerous from the point of view of cracking; A wide range of measurements of the magnitude of the magnetic field induction; The smallest measurement error among analogues in the entire operating temperature range; Convenience of measurement by a remote measuring transducer in various planes; Low power consumption and, as a result, long working time; Low cost compared to similar models on the market; Compact dimensions; Manufacturer's warranty – 12 months; The device is included in the state register of measuring instrument RU.C.27.004.A No. 36079 dated 01.09.2009 and has undergone a verification procedure. Magnetometer MX-10 (milliteslameter) it is also included in the register of measuring instruments, test equipment and measurement methods used in JSC "Russian Railways". Scope of application 1. Verification of the magnetization modes of controlled parts using permanent magnets, rectified current electromagnets by the applied field method, as well as during the control by the residual magnetization method, by measuring the tangential and normal components of the magnetic field strength vector at one or more points on the surface of these parts. The number of points at which the magnetic field strength is measured and their location on the controlled surface depend on the shape of the part, as well as on the type and design of the magnetizing device used. 2. Control of the magnetization of parts before welding. During electric arc welding of non-magnetized parts, the effect of "magnetic blowing" is observed, i.e. the deviation of the electric arc from the axis of the electrode, the wandering of the arc end along the product, which leads to metal splashing during welding, deterioration of the seam quality. Therefore, before welding, it is necessary to measure the level and direction of magnetization of the parts and demagnetize them if necessary. 3. Verification of the residual magnetization after magnetic powder inspection. Demagnetization and verification of the residual magnetization of responsible, rubbing parts, as well as parts in contact with them after assembly, is prescribed in the requirements of the IPC and is a technological stage of control. 4. Magnetization control before assembling various structures. Magnetized parts can affect the operation of automation devices, cause errors in the readings of instruments, equipment. Magnetization can cause the accumulation of wear products in the movable joints, cause a negative effect on subsequent technological operations. Due to possible undesirable consequences, the parts are demagnetized and the quality of their demagnetization is checked. 5. Control of gas and water meters. Housing and utilities enterprises may also be interested in the device. It is known that existing gas or water flow meters can be easily "deceived" with the help of strong permanent magnets that reduce the rotation speed of the flow sensors. There are different ways to detect such theft. One of them is the control of the residual magnetization of the counters using magnetometers. The measured value should not significantly exceed the Earth's magnetic field, otherwise it can be concluded that there was unauthorized interference with the operation of the device. Main technical characteristics Measuring range, MT from 0.1 to 100 The limits of the permissible basic absolute measurement error, MT D = 0.02 VI + 0.05, where VI is the magnetometer readings in MT Power supply battery type: PP3 (nine-volt battery) Consumption current, mA, no more than 15 Duration of continuous operation (from fully charged batteries), h, at least 20 Overall dimensions, mm: – electronic unit (LxWxH) 120x60x25 – Measuring transducer (Diameter x Length) 18x173 Weight, g, not more than 160 Ambient operating temperature, °C -10...+40
Produced in: Moscow
Installation for verification of individual beta radiation dosimeters UPB-ID
Installation for verification of individual beta radiation dosimeters UPB-ID
Installation for verification and calibration of individual beta radiation dosimeters. Properties The unit transmits units of absorbed dose (PD) and absorbed dose rate (MPD) of beta radiation in a tissue equivalent substance at a depth corresponding to a surface density of 7 mg•cm-2; the transition to units of the individual equivalent of the Hp dose (0.07) in sieverts from units of beta radiation absorbed in the tissue in gray is carried out using conversion coefficients recommended by the international standard ISO 6980-3:2006; the installation can be used in metrological bodies for verification of individual beta radiation dosimeters such as DMC 2000 XB, EPD Mk2 and others.
Doza
Zelenograd
Produced in: Moscow
MF-23IM Flaw detection magnetometer
MF-23IM Flaw detection magnetometer
from 168 000 ₽
The MF-23IM flaw detection magnetometer allows you to determine the compliance of the ratio of the tangential and normal components of the magnetic field strength during magnetic particle testing using both the applied field method (AFM) and the remanent magnetization method (RMM) in accordance with the requirements of current regulatory documentation. The MF-23IM flaw detection magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities.

The flaw detection magnetometer is included in the State Register of Measuring Instruments (GRSI) under No. 20106-00. The magnetometer (milliteslameter) is also included in the register of measuring instruments, testing equipment and measurement methods used at JSC Russian Railways. The flaw detection magnetometer MF-23IM from the manufacturer is used to measure the parameters of constant, variable (industrial frequency) and pulsed magnetic fields when testing ferromagnetic products using the magnetic particle method, as well as to control the level of industrial interference. Specifications.
Magnetic field induction (strength) measurement range: - constant and variable (amplitude and average values) 0.5…1000 mT (4…8000 A/cm) - pulsed (amplitude value) 2…1000 mT (18…8000 A/cm) Indication of measurement results digital or digital + graphic Indicator liquid crystal display Power supply from 1 PP3 battery Current consumption, mA, no more than 15 Memory capacity for storing results 4080 Communication with a computer via infrared channel Dimensions of the electronic unit, mm, no more than 120x60x25 Weight of the electronic unit with battery, g 150

The minimum dimensions of the Hall transducer for the MF-23IM magnetometer make it possible to measure the induction and magnetic field strength in grooves, grooves, corner transitions, i.e. in those areas of the controlled product that are stress concentrators and the most dangerous from the point of view of crack formation; · Measurement of pulsed magnetizing field with pulse duration from 0.5 ms; · Small measurement error (see technical specifications table) · Compact size and low power consumption;

· The magnetometer has 2 modes for displaying measurement results – digital and graphic). The MF-23IM magnetometer in graphical display mode allows you to detect a demagnetizing pulse by displaying its shape and amplitude on a graphic display, as a result of which changes can be made to the magnetization circuit in a timely manner. · The software of the MF-23IM magnetometer allows you to flexibly configure not only the response thresholds, but also the time base, which allows you to tune out false indications caused by reverse emissions of the magnetic field or electromagnetic interference from operating power equipment (magnetizing devices or magnetic particle flaw detectors).

· Determination of the effective magnetization region, within which the tangential component of the magnetic field strength is sufficient for magnetic particle testing, and the ratio of the normal and tangential components of the magnetic field strength is less than or equal to 3. · Checking the mode of magnetization/demagnetization of test objects for compliance with the methodology/technological instructions for magnetic particle testing for a given object.

BASIC SET: Electronic unit Converter 1 Converter 2 Caliber PP3 battery CD with program Case Flaw detection magnetometer MF-23IM. Passport
Produced in: Moscow
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
Universal reader UZS-01D / UZS-02D
Universal reader UZS-01D / UZS-02D
Purpose: to provide bidirectional data exchange with individual dosimeters DKG-05D, DVS-02D.
Doza
Zelenograd
Produced in: Moscow
Installations for verification of gamma radiation dosimeters portable UPGDS-3D
Installations for verification of gamma radiation dosimeters portable UPGDS-3D
Appointment: for transmitting units: the kerma power in the air of gamma radiation (MC); the ambient dose equivalent of gamma radiation (MAED); the power of the directional equivalent of the dose of gamma radiation (MNED); the exposure dose of gamma radiation (MED); the absorbed dose in the air of gamma radiation (MPD); it is used for verification and calibration of dosimetric measuring instruments in the gamma radiation field of the Cs-137 source under normal climatic conditions; it can be used as part of mobile laboratories, portable verification posts at enterprises.
Doza
Zelenograd
Produced in: Moscow
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Appointment: continuous pumping of atmospheric air with a constant flow rate through a filter element based on Petryanova fabric. measurement of ionizing radiation parameters at a controlled point in accordance with the capabilities of the unit used.
Doza
Zelenograd
Produced in: Moscow
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Portable flow meter-sampler of gas-aerosol mixtures PVP-06
Purpose measurement and control of the pumping speed and the total volume of the aerosol mixture pumped through the filters installed on the product during sampling in order to determine the content of aerosol pollutants in the air
Doza
Zelenograd
Produced in: Moscow
Multifunctional UKRV-2 air flowmeter
Multifunctional UKRV-2 air flowmeter
Purpose: measurement of the volume of air pumped through the analytical filter; measurement of volumetric air flow through an analytical filter. Features: output of information to the LCD indicator; automatic and manual control of an external actuator (valve, crane); obtaining information about the analytical filter used using a barcode reader; transmission of data on the state of the device, the measured volume flow and the pumped volume of air to communication channels; providing access to information via the RS-485 interface; work both independently and as part of radiation monitoring systems
Doza
Zelenograd
Produced in: Moscow
Gamma radiation dosimeter DKG-03D "Grach"
Gamma radiation dosimeter DKG-03D "Grach"
Purpose: measurement of the ambient dose equivalent of N*(10) gamma radiation; measurement of ambient dose equivalent of N*(10) gamma radiation (operator dose).
Doza
Zelenograd
Produced in: Moscow