Search

62 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 1
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 18
    Applying
    Loading...
  • Names
    Loading...
  • 14
    Manufacturer
  • 13
    Made in
  • 8
    Additional
View:
62 products
DOSIMETER DKS‑AT5350/1
DOSIMETER DKS‑AT5350/1
A high-precision dosimeter with extensive functionality: measurement of DC power, electric charge, charge by numerical integration of current, kerma and kerma power in the air, kerma by numerical integration of kerma power and other radiological quantities. Composition of the dosimeter: - Electrometric measuring unit (electrometer) - PTW-Freiburg ionization chambers (Germany) to choose from: TM23342 Flat-parallel X-ray (volume 0.02 cm3) TM31010 Cylindrical (volume 0.125 cm3) TM30010 Thimble (volume 0.6 cm3) TM23361 Cylindrical (volume 30 cm3) TM32002 Spherical (volume 1000 cm3)
Produced in: Belarus, Minsk
IPEP-1 Electrostatic Field Parameter Meter
IPEP-1 Electrostatic Field Parameter Meter
Designed to measure the potentials of electrostatically charged objects, the strength of the electrostatic field and the surface density of electric charges. Technical specifications: Measuring range 0.02-50 kV The error is 5-10% The intensity of the electrostatic field Measuring range 2-1000 kV/m Error 5% Surface density of electric charges Measuring range 0.02-10 µcl/m2 Error 5% Measurement of the electrostatic field strength (2-1000 kV/m) Measurement of the potential of charged objects (0.02–50 kV) Measurement of surface charge density (2x10-8–1x10-5Kl/m2) Measurement error ±(5-10) % Laser pointer of the distance to the object (2, 10 cm) 3.5-digit indicator (LCD with image flip) RS-232C interface Dimensions, weight 40x106x268 mm, 0.7 kg Built-in battery for 8 hours of operation Power supply: ~220, 5 VA, 4.5–5.5 VA battery
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring recorder IS-203.2.0
Measuring recorder IS-203.2.0
from 24 480 ₽
The meter-recorder IS-203.2 is a microprocessor-based meter designed to measure temperature. Equipped with a non-volatile storage device and a real-time clock. The device has two measuring channels. The measurement results are stored in the non-volatile memory with a volume of 15,000 measurements per channel. The operating conditions of the meter IS-203.2.0 Ambient temperature, ° C: -20...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7. Scope of application of the meter IS-203.2.0 Control of technological processes in various industries, including: utilities, construction, food and pharmaceutical industries, agriculture, etc. Warehouses (grocery, industrial, pharmaceutical, etc.). Transportation (grocery, industrial, pharmaceutical, etc.). Functionality of the meter IS- 203.2.0 Temperature measurement by external sensors. Saving the measurement results in the device memory. Indication of the results of current measurements, time, channels included, interval between measurements, free memory of the device, battery capacity, serial number of the device, time of the next measurement. Operational start and stop of the measurement process. Data transfer to a PC via a COM port or USB.
Produced in: Kolomna, Moscow region
The self-recording meter IS-203.1.1
The self-recording meter IS-203.1.1
from 8 520 ₽
The measuring recorder IS-203.1.1 is designed to measure and register temperature with a specified time interval between measurements by direct contact of the device with the measuring object. The features of the meter IS-203.1.1 Ease of operation. Reliability. The operating conditions of the meter IS-203.1.1 Ambient temperature, ° C: -30...+85. Relative humidity, %: no more than 80% at T = 35 ° C. Atmospheric pressure, kPa: 86...106.
Produced in: Kolomna, Moscow region
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
The set for temperature control during transportation of perishable food and ILP
The set for temperature control during transportation of perishable food and ILP
The body of the refrigerator for transportation is equipped with two temperature sensors and a two-channel meter recorder IS-203.2, which is installed in the driver's cab. The meter-recorder IS-203.2 is a microprocessor device that allows the driver to visually monitor temperature changes. This device is equipped with a non-volatile storage device and a real-time clock, has two measuring channels. The measurement results are stored in a non-volatile memory with a volume of 15,000 measurements per channel, followed by data transfer to a computer (RS 232 or USB) for visualization in the form of tables and graphs. Features of the kit for temperature control of food and ILP Measured temperature range: -50...+100°C. Resolution: 0.1°C. The limit of permissible absolute error: ± 0.5 ° C
Produced in: Kolomna, Moscow region
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
Detection of gamma and neutron radiation sources in the flow of pedestrians crossing the border of the controlled object. Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software High reliability and self-control Backup power supply At the request of the user, the MCI can be supplied without a neutron channel.
Produced in: Belarus, Minsk
External temperature sensor PT 1000
External temperature sensor PT 1000
from 6 120 ₽
Основные характеристики Диапазон измерения температуры, °С От -70 до + 200 Погрешность измерения температуры, °С, не более 1 Номинальное сопротивление при 25 С,кОм 1.0 Длина рабочей части PT 1000 (погружной) 250 мм Длина ручки 50 мм, диаметр ручки М12 Длина провода до 600 мм
Primelab
Mytishchi
Produced in: Moscow region, Mytishchi
Central Heating Unit Medium (CHU-M) Kit
Central Heating Unit Medium (CHU-M) Kit
The kit is designed to control the temperature and pressure at the points of water sampling of hot water and HVAC systems, archiving the measured results for the purpose of their further documentation and analysis. The TSTP-M kit allows you to record changes in temperature and pressure directly at the points of water intake of hot water and HVAC, for a long period. With the subsequent transfer of data recorded in the device's memory to a computer, for printing a report, graph, etc. Features of the CHU-M kit The CHU-M kit allows you to control the pressure and temperature at the hot water and HVAC disassembly points. The kit consists of a four-channel meter recorder, which allows you to store 15,000 values in memory, for each channel with an interval of 5 seconds. up to several hours, which allows you to take measurements and store data for up to 1 year.
Produced in: Kolomna, Moscow region
UShS "Tapirus" with cover and supports
UShS "Tapirus" with cover and supports
from 18 000 ₽
The UShS TapiRus is designed to replace numerous templates and devices used in visual and measuring quality control of welded joints. It is approved as a means of measuring the geometric parameters of welded joints and surface defects during visual and measuring control (VIC) and supplied with verification. It allows you to determine most of the geometric parameters of welded joints and surface defects: the width and convexity of the seam, the depth of the cut, the amount of edge displacement, the angle of the angular seam, the angle of the bevel and the gap, etc. Equipped with supports that allow you to uniquely position the template on a curved surface. To carry out measurements with an error of 0.1 mm, scales with a vernier are applied to the TapiRUS surface. It contains a number of gauges for assessing the smooth transition from the deposited to the base metal, the size of the cathets, radii and angles of cutting edges. Equipped with a probe with a replaceable measuring needle to determine the size of gaps and heights / depressions. The development, preparation for production and manufacture of TapiRus were carried out exclusively in digital format. The latest laser and additive technologies are used in the production of TapiRUS: high-precision laser cutting machines in inert gas; five-axis CNC machining centers; ultra-precise color laser engraving of the entire product assembled; laser stereolithography (SLA) is a technology of layer–by-layer synthesis of a material from a liquid photopolymer. Advantages Easy to install. Accurate positioning along the normal to the surface of the object of control and stability of the position when performing measurements. Functionality. Measurement of most geometric parameters of welded joints and surface defects. Measurement accuracy. The measurement error on the template scales does not exceed 0.1 mm. Modernity. Online calculator ergonomic accessories smart version. More detailed information can be found on the website tapirus.info MEASURED PARAMETERS AND DEFECTS VIC at the stage of input control wall thickness depth of corrosion ulcers on the base metal the depth of corrosion ulcers on the weld the depth of scratches (risks), a bully on the base metal edge bevel angle the amount of blunting geometric parameters of the dent VIC during assembly (preparation for assembly) edge offset withdrawal (angularity) of edges the gap in the cutting the height of the potholders angular displacement VIC in the welding process (surfacing) edge offset height of the root (filling) layer withdrawal (angularity) of edges angular displacement VIC of finished welded joints (structures) edge offset angular displacement the height of the reinforcement of the seam the height of the bulge (when welding elements of different thickness) the width of the reinforcement of the seam withdrawal (angularity) of edges the depth of the sinking between the rollers incomplete filling of the cutting edges scaliness of the seam surface smooth transition undercut depth seam crater depth technical specifications Measured parameter Scale Range,mm Error, mm Depth, mm H 0...20 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Height, mm H 0...6 ±0.1 Width, mm W 0...55 ±0.1 (in the range 0...10 on), ± 0.5 (in the range over 10...20) Clearance, mm N 0...5 ±0.1 Dullness, mm F, G 0...25 ±0.5 Specifications Overall dimensions, mm, no more (without supports) 115x85x15 ± 0.5 (with supports) 115x85x42 ±0.5 Average time to failure, cycles, at least 55,000 Weight, kg, not more than 0.22 Average service life, at least 1 year
Produced in: Moscow