Adsorption dryers with hot regeneration
Adsorption dryers with hot regeneration
The Provita company offers adsorption dryers with cold and hot regeneration of its own production. Industrial installations are equipped with high-quality components that ensure reliability and long service life. They are capable of operating at a pressure of 4 to 16 bar and are drained to a TRD (dew point under pressure) of -70 ° C. Working pressure: 4 — 16 bar Dew point: -20 to -70°C Capacity: from 50 to 20000 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Adsorption dryers with cold regeneration
Adsorption dryers with cold regeneration
The Provita company offers adsorption dryers with cold and hot regeneration of its own production. Industrial installations are equipped with high-quality components that ensure reliability and long service life. They are capable of operating at a pressure of 4 to 16 bar and are drained to a TRD (dew point under pressure) of -70 ° C. Working pressure: 4 — 16 bar Dew point: -20 to -70°C Capacity: from 50 to 5000 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
High pressure gas flow regulator RRG-VD
High pressure gas flow regulator RRG-VD
It can be used as a primary source of carrier gas, since it is equipped with an additional gas purification system. This device is especially relevant when, for some reason, helium is not available to the consumer (for example, when working with a thermal conductivity detector - an accident). Due to the high thermal conductivity of hydrogen, TTP operates with significantly greater sensitivity than helium.
Produced in: Yoshkar-Ola, Mari El
DIGITAL MULTICHANNEL LEAK
DIGITAL MULTICHANNEL LEAK
The Meta-chrome digital gas flow meter is designed to maintain a given pressure and the ratio of the amount of gases (in the flow mode) or gas flow (in the intake mode) in vacuum installations with automatic and manual control. technical specifications The number of control channels is 2 (or more on request). The maximum flow rate for each of the channels is 700 cm3/min. The possibility of using gas correction coefficients, the most commonly used gases are listed in the leaker database. The accuracy of maintaining a given proportion of gases is 5%. The accuracy of maintaining the specified gas flow rates is 3%. Input pressures from 1 to 4 atm. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption (without a personal computer), no more than — 30 VA. Overall dimensions (width × depth × height), no more than 165×350×215 mm. Weight, not more than 5.5 kg.
Produced in: Yoshkar-Ola, Mari El
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
Vacuum membrane pump PL.HM03.02.45 Primelab
Vacuum membrane pump PL.HM03.02.45 Primelab
from 110 000 ₽
Vacuum membrane pump PL.HM03.02.45 Primelab is an effective device for creating a vacuum, pumping gases and vapors. It has a high pumping speed (38 l/min) with a maximum residual pressure of 45 mbar. All materials in contact with the working fluid are made of PTFE. This material has rare chemical and physical properties. In this case, the pump does not require regular maintenance. Ease of use and reliability make the PL.HM03.02.45 diaphragm vacuum pump an ideal option for laboratories of any scale and production that require high-quality and controlled evacuation.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum membrane pump PL.HM04.02.01 Primelab
Vacuum membrane pump PL.HM04.02.01 Primelab
from 490 000 ₽
Vacuum membrane pump PL.HM04.02.01 PrimeLab is a compact laboratory device with which you can create a vacuum in the laboratory. It is equipped with innovative membrane technology that ensures high gas pumping speed. Suitable for pumping vapors and gases up to 1 mbar. The PL.HM04.02.01 pump has an excellent safety system. Protection against overheating and overload is provided. All contacting media are made of PTFE, which has rare chemical and physical properties. All control is carried out through vacuum control, which also ensures maximum accuracy and control of all operating parameters. It has a low noise level (75 dB), which does not cause discomfort to the working class.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Vacuum combined chemical-resistant membrane pump PL.HM02 up to 10 or 50x2 mbar Primelab
Vacuum combined chemical-resistant membrane pump PL.HM02 up to 10 or 50x2 mbar Primelab
from 145 000 ₽
1 supp.
Characteristics Valve(s) material Standard: chloroprene copolymer NO-68-1 (TU 38 0051166-98) A country Russia Overall dimensions, L×W×H, mm 322x140x200 Protection class acc. to DIN EN60529 IP20 Noise level, dB 75 dBA Nutrition 230 V, 50 Hz Material working chamber PTFE (fluoroplastic) Ultimate vacuum, mbar abs. 10 for serial, 50 for parallel, 50x2 for independent connection Excess pressure, bar. Maximum permissible excess operating pressure 0.5 bar Productivity, l/min 76 with parallel, 38 with serial, 38x2 with independent connection Maximum current, A 1.2 Equipment Vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately). Device weight, kg 8.6
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Pure nitrogen generator GCHA-120
Pure nitrogen generator GCHA-120
from 382 800 ₽
GCHA-120 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is at least 120 (2.0 l/min), l/h Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 3600 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-21D
Pure nitrogen generator GCHA-21D
from 276 000 ₽
An analogue of GCHA-21, but equipped with a built-in system of catalytic purification of the resulting nitrogen from hydrocarbons. GCHA-21D nitrogen generators are designed to produce nitrogen of the highest purity in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % vol. (including impurities of inert gases: argon, neon, helium) 99,999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a concentration of methane in the supply air not more than 5 ppm)* 0.00001 (0.1 ppm) Maximum nitrogen capacity is not less than 21 liters/hour (350 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is 5 ati Compressed air consumption, at nominal inlet pressure is no more than 300 l/h (5 l/min) Power consumption is not more that 110 VA Overall dimensions, (width x depth x height) are not more than, mm 230x425x510 Weight, not more than, kg 25 Working conditions: Ambient temperature, °C from +10 to +35 Electric power supply from a single-phase AC network with a voltage of 220 ± 10% and a frequency of 50 ± 1 Hz Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Nitrogen Generator GA-400-K
Nitrogen Generator GA-400-K
The nitrogen generator is designed to create an inert atmosphere, fill low-pressure tanks, "wash" test tubes with inert gas and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. The warranty for the device is 18 months, for the built–in compressor - 12 months from the date of sale. Technical specifications Volume fraction of nitrogen is not less than 99.5 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5% vol. (ppm) Volume fraction of water vapor is not more than 0.002 % vol. (ppm) (20 ppm) Maximum nitrogen capacity is not less than 400 l/hour (6.66 l/min) Nitrogen outlet pressure is 4±0.2 ati The time of setting the operating mode for single-shift operation is no more than 45 min Noise level generated by the compressor is no more than 60 db Power consumption is not more than 800 VA Overall dimensions, (width x depth x height) are not more than 360x680x550 mm Weight is not more than 46 kg Operating conditions: ambient air temperature, oS from +10 to +35 electric power supply from single-phase AC voltage, 220 ± 5% frequency, Hz 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of GOST 12.2.025-76. class 1, type
Produced in: Moscow
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 200 400 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow