Septa for Fischer titrators C20, C30, DL32, DL39
Septa for Fischer titrators C20, C30, DL32, DL39
from 3 600 ₽
Septa for titrators are made of fluorosiloxane rubber. The main difference between this material and traditional silicone is the presence of trifluoropropyl groups in the chain, which give fluorosiloxane rubber chemical resistance to solvents, fuels, oils, acids, alkalis, and a number of oxidants, as well as a wide operating temperature range from -60 to +200℃. Characteristics of the septa produced by us for the L 51108740 titrator: Diameter -12 mm Thickness - 2 mm Color - white Density -1.50 ± 0.05 g/cm3 Hardness -60- 70 units. Shore A
LABEX
Saint Petersburg
Produced in: Saint Petersburg
Seal for Mettler Toledo T50, T70, C20, C30, V20, V30 Titrators
Seal for Mettler Toledo T50, T70, C20, C30, V20, V30 Titrators
from 2 700 ₽
A set of ring seals for burettes of Mettler Toledo titrators of the T, DL, V series, as well as pumps for changing reagents of Solvent manager. In a package of 5 pcs. Material: fluorosiloxane rubber. The flat ring seal is used to seal the burette and bottle of the Mettler Toledo T50, T70, T90, G20, G10, V20, V30, C20, C30, DL titrators, as well as the pump and bottle of the Fischer reagent replacement module.
LABEX
Saint Petersburg
Produced in: Saint Petersburg
Automatic installation of LK-100 for Kjeldahl decomposition (Thermoset reactor)
Automatic installation of LK-100 for Kjeldahl decomposition (Thermoset reactor)
1 supp.
Technical specifications: Maximum heating power, W 1500 Working volume of reaction tubes, 250 ml Number of reaction tubes 6 Power consumption from the mains 220 V, W 1550 Overall dimensions, mm 480x526x750 Weight, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg
MARK -1202
MARK -1202
The device is designed for high-precision measurements of silicon dioxide in process waters of thermal and nuclear power plants, for monitoring water treatment processes in various industries. The device is based on a photometric measurement method with automatic dosing of reagents. MARK-1202 can be used not only as an automatic, but also as a laboratory analyzer. The warranty is 24 months for deliveries across the Russian Federation. Multithreaded analysis capability From 1 to 6 channels Current outputs, RS-485 digital interface Universal analyzer for automatic and laboratory control Minimum maintenance Self-diagnosis Graduation no more than once every 3 months Low cost of operation Reagents of Russian production Simple, intuitive interface Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK® 01 MK
MARK® 01 MK
Cooling, throttling, filtration and regulation of sample flow. Indication of temperature, pressure and flow of the sample. Temperature, pressure and cooling water flow indication (optional). Sample preparation for water-chemical regime monitoring devices at energy facilities. Continuous monitoring of sample parameters and data transmission via digital and current outputs. Maintaining stable sample pressure. Alarm and automatic shut-off of the sample supply in case of violation of the regime. Custom temperature and pressure settings for automatic shut -off of sample supply. Pulse line purge valve. Compact stainless steel panel 350*944 mm. One-way service. Easy-to-clean collapsible heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Heat exchanger TO-290/ TO-145
Heat exchanger TO-290/ TO-145
It is used in technological processes of nuclear, thermal and electric power plants, boiler houses and other facilities for cooling samples supplied to automatic and manual chemical control devices.Easy-to-clean collapsible structure. Materials with high mechanical properties are used: the coil is made of 316 SS steel, the body is made of 304 steel (or 12X18H10T). It is equipped with crimp fittings for connecting sample lines without welding. It is equipped with a special three-way ball valve for supplying / draining cooling water and a control valve that provides a change in the flow of cooling water through the heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
The AP-35 analyzer is a fully automated analytical complex designed for continuous X-ray fluorescence analysis of the chemical composition of slurries and solutions in flow. The instrument has a movable software-controlled measuring head with an X-ray tube and fixed spectrometric channels (up to 8), each of which can be set up for any chemical element (from Ca to U). In operation, up to 15 flow cells are measured by the head according to a preset program. Multi channel capability (up to 15 products to be measured). Compatibility with automation systems for sampling, sample delivery, data handling and presentation, data archiving. Link to factory process control system High expressiveness, high analytical precision, low detection limits, reproducibility High reliability. The principle of operation is based on the excited fluorescence produced by the atoms of the material under analysis through the radiation of an X-ray tube. The fluorescence radiation of a particular chemical element is picked up by the crystal analyzer, and then the radiation at a specific wavelength is detected by an X-ray tube detector. The intensity of the recorded fluorescence radiation of a certain wavelength is directly proportional to the mass fraction of the chemical element in the substance under study.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Automatic installation of LK-500 for distillation of c by Kjeldahl
Automatic installation of LK-500 for distillation of c by Kjeldahl
Technical specifications: Reagent volume setting range, ml 0 ... 200 The range of setting reaction and distillation times, min 0 ... 60 Steam power setting range, %30 ... 100 Average distillation time of the sample, min 2 ... 4 Water consumption for cooling, l/min 5 Power consumption from the mains 220 V, W 2200 Overall dimensions, mm 460x370x760 Weight, kg 35
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Na-meter MARK® 1002
Na-meter MARK® 1002
Measurement of the activity of sodium ions (CNa) and the temperature of aqueous media. Control of parameters of water-chemical regimes at thermal and nuclear power facilities.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points of CNa or pNa, temperature. Convenience and accuracy of measurement, minimum maintenance | Measurements from 0.01 CNa. The typical error is 6%. Long intergrading interval (up to 6 months). Automatic thermal compensation. Automatic dosing device of the alkalizing reagent. No capacity with KCl. Calibration by one solution | If necessary, three-point calibration is possible. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable settings of the "dry" contact type.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
A set of equipment for determining the total sludge content in residual liquid fuels OPF-LAB-02
A set of equipment for determining the total sludge content in residual liquid fuels OPF-LAB-02
Features: Sediment measurement up to 0.5% by weight; Two brass test cells; Coils for heating/cooling each cell; Buchner flask 500 ml in a protective casing; Steam generator with a capacity of 1.7 liters; Vacuum gauge; Thermocouple for determining the temperature of steam at the entrance to the cell circuit; 6-bed water bath for sample preparation included; Tubes for steam, water, vacuum tubes included. The composition of the kit: Filter unit OPF-LAB-02 1 pc. LOIP SG-101 steam generator 1 pc. Vacuum source 1 pc. Liquid thermostat LOIP LT-840 1 pc.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Technical specifications: The volume of the analyzed sample is 5 ml The volume of the test chamber is 25 ml Test temperature 37.8°C Accuracy of maintaining the temperature of the chamber ±0.1 °C Pressure measurement range 0.01...200 kPa Pressure measurement accuracy ±0.01 kPa Gas/liquid ratio 4/1 Power consumption from 220 mains, no more than 150 watts USB, LAN interface Overall dimensions, no more 450x230x190 mm Weight, not more than 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg