      DC power supply B5-79
      DC power supply B5-79
      The B5-79 DC power supply is designed to provide constant voltage and current to measuring instruments and equipment during the development, production, operation and repair of electronic devices. Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Maximum output power 300W The main error of the output voltage setting is ± 300 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
      Device for measuring attenuation DC1-28
      Device for measuring attenuation DC1-28
      The device is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 interfaces (CPC). Technical specifications Frequency range from 100 kHz to 37.5 GHz VSWR input of the device with a matching fixed attenuator attenuation of 10 dB, depending on the frequency range, no more • from 100 kHz to 180 MHz 1.15 • from 0.18 to 2 GHz 1.25 • from 2 to 12 GHz 1.30 • from 12 to 17.85 GHz 1.50 • from 17.85 to 37.5 GHz 2.00 Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 125 VA Overall dimensions, mm 216x493x508.5 Weight, not more than 32 kg
      Produced in: Moscow
      High-frequency signal generator G4-229
      High-frequency signal generator G4-229
      The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range (RF output) from 9 kHz to 6 GHz Frequency range (LF outputs) from 0.001 Hz to 30 MHz Frequency tuning discreteness (RF output) 1 Hz Frequency tuning discreteness (LF outputs) 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main RF output is from minus 120 to 13 dBm The range of setting the signal amplitude at a load of 50 ohms (LF outputs) from 0.01 to 5 V The basic error of setting the reference power level (RF output) ± (0.5 – 1.0) dB The basic error of setting the amplitude of sinusoidal signals (LF outputs) ± (3 – 15)% Instability of the signal power level for any 15-minute time interval (RF output) no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the basic error of setting the frequency deviation ± (10 – 20)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient (when operating from an internal signal source) ± (0.15 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
      Produced in: Moscow
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      Mobile laboratory of measuring equipment PLIT-A2-4/1M
      The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a preset temperature level (20 ...25) ° C in the van body, at an outdoor temperature from minus 40 ° C to 40 ° C. PLIT-A2-4/1M is equipped with a removable diesel electric unit with a capacity of 16 kW, which ensures the functioning of all systems in autonomous mode. A set of functionally related working standards, special equipment and automation tools allows you to implement comprehensive metrological maintenance of measuring instruments at workplaces
      Produced in: Moscow
      PKV-IP-11×5.5
      PKV-IP-11×5.5
      Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications the length of the waveguide, mm 11×5.5 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 17.44-25.96 VSWR 1.25
      Produced in: Moscow
      DC power supply B5-79/1
      DC power supply B5-79/1
      The source is capable of operating both independently and as part of automated measuring systems with interfaces such as RS-232 and ETHERNET Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Electrical output power, not less than 300 W The main error of the output voltage setting is ± 100 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
      Produced in: Moscow
      Verification module PM-3
      Verification module PM-3
      The composition of the PM-3 verification module: Frequency comparator CHK7-1011; Universal frequency meter Ch3-86A; Universal voltmeter V7-79; Absorbed power wattmeter M3-108-2; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Generator of test pulses G9-1A; Oscilloscope S1-177; DC power supply B5-79/1; Electronic switchboard of RF signals; AC power source B2-7 (2 pcs.); PC, printer; Basic load-bearing structures (BNC). Technical specifications Measurement ranges of time-frequency parameters of signals: Continuous oscillation frequency from 0.005 Hz to 17.85 GHz Pulse repetition rate from 0.01 Hz to 100 MHz The carrier frequency of the IM signal is from 100 MHz to 17.85 GHz Pulse duration from 10 ns to 1000 s Time interval from 0 to 1000 s Nominal values of the frequency of the studied signals are 2,048; 5,0; 10,0; 10,24 MHz Measurement errors of time-frequency parameters of signals: Frequency of continuous oscillations ± (2,4·10-10 - 4·10-3) Pulse repetition rate ± (2·10-7 - 2·10-3) The carrier frequency of the IM signal is ± 2·10-7 Pulse duration ± (1 - 200) ns Time interval ± (1 - 200) ns The relative deviation of the frequency of the studied signal from the reference frequency ± (5·10-13 - 2·10-12) Frequency of continuous oscillations ± (3·10-11 – 1,1·10-5) Pulse repetition rate ± (2·10-11 – 6·10-5) Carrier frequency of the IM signal ± (3·10-11 – 1,1·10-5) Pulse duration ± (1·10-8 – 7,2·10-4) Time interval ± (2·10-10 – 7,2·10-4) Nominal values of the reference signal frequency ± (2·10-11 – 2,4·10-10) General technical characteristics: The area occupied by the module is 8-12 m2 Weight, not more than 327 kg Power supply voltage from 198 to 242 V frequency (50 ± 0.5) Hz Power consumption, no more than 2400 VA
      Produced in: Moscow
      Universal voltmeter V7-79
      Universal voltmeter V7-79
      The voltmeter is capable of operating both independently and as part of automated measuring systems with RS-232 interfaces. Technical specifications Measuring ranges of electrical quantities: - constant electrical voltage from 10 MV to 1000 V - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) from 1 mV to 750 V - RF RF AC voltage in the frequency range from 10 kHz to 1500 MHz (RF) from 10 mV to 1000 V - DC electric current from 0.1 µA to 20 A - SCZ of alternating electric current in the frequency range from 10 Hz to 5 kHz from 10 µA to 20 A - electrical resistance from 10 mOhm to 1 GOm - frequency of the measured AC voltage from 10 Hz to 1 MHz Measurement errors of electrical quantities: - constant electrical voltage ± (0.0028 - 20)% - SCR of alternating electric voltage in the frequency range from 10 Hz to 10 MHz (AC) ± (0.09 - 15)% - RF RF AC voltage in the frequency range from 10 kHz to 1500 MHz (RF) ± (1.6 - 66)% - DC current ± (0.012 - 20)% - SCR of alternating electric current in the frequency range from 10 Hz to 5 kHz ± (0.11 - 2.35)% - electrical resistance ± (0.007 - 5.5) % - frequency of the measured alternating electric voltage ± (0.1 -10.1) % General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 20 VA Overall dimensions, mm 291x110x308 Weight, not more than 4.5 kg
      Produced in: Moscow
      VD-7.2×3.4
      VD-7.2×3.4
      A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
      Produced in: Moscow
      Stationary metrological laboratory
      Stationary metrological laboratory
      The SML is a stationary object located in the existing production premises of the customer or new buildings built according to the project documentation. The technical basis of the SML is made up of up to ten automated workstations (APM ST) for SI verification (calibration) and up to three workstations (RM ST) for diagnostics, adjustment and repair of SI. The ARM ST includes software that allows you to perform SI verification according to a given algorithm and document the results. All SML equipment is placed on standard basic load-bearing structures (BNC). At present, design documentation has been developed and the production of automated control systems has been mastered for the complete set of SML of almost all types of radio and electrical measuring devices, pressure and vacuum SI, SI geometric quantities and other SI. If necessary, the specialists of JSC "NPF "Techno-yaks" are ready to train specialists (ARM operators). Terms and conditions of financing, development, manufacturing, installation, training of specialists are implemented on the basis of contractual relations with customers
      Produced in: Moscow
      Universal frequency meter Ch3-89
      Universal frequency meter Ch3-89
      The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
      Produced in: Moscow
      High-frequency signal generator G4-232
      High-frequency signal generator G4-232
      A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
      Produced in: Moscow