Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
Anemometer AP1M with a wing sensor AP1M1
Anemometer AP1M with a wing sensor AP1M1
from 49 054 ₽
Range: 0.3-5.0 m/s; Accuracy Characteristics: (0.1+0.05V) m/s; Weight: 0.6 kg; Powered by a 4.8V rechargeable battery; Power consumption 0.1 VA; Application conditions: for primary measuring transducers: from minus 10C to plus 50C in the range of 0.3-5 m/s. for the digital measuring console: from minus 10C to plus 50C. Relative humidity 45-80% at temperature (25±10)With; Continuous operation time at negative temperatures up to minus 30C is no more than 1 hour;
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
Atom Fast 8816 - radiation dosimeter on a scintillator for a smartphone
Atom Fast 8816 - radiation dosimeter on a scintillator for a smartphone
from 29 500 ₽
1 supp.
Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device Full charge time The time to fully charge the built-in battery from a PC USB port or charger is no more than 4 hours. Operating time from a fully charged built-in battery under natural radiation conditions without the use of wireless communication and sound/vibration alarms is at least 4 months Maximum counting speed (imp/sec) is not less than 10,000 imp/s (600,000 imp/min). Device weight (g) no more than 50
Note Atom Fast can withstand irradiation with a dose rate of up to 2000 R/h for 2 s without damage and fully restores functionality after cessation of irradiation in no more than 2 s. Operating temperature range from -40 to +40 degrees. C (for the “new” detection block edition from the fall of 2019, the range is from -20 to +40). When the temperature rises above +40 degrees. C, the device will warn the user about this with the sound of a two-tone siren repeating once a minute. With a further increase in temperature, correct operation of the device is not guaranteed. Energy range of detected photon radiation (keV) Working size of scintillation detector (mm) 8*8*16

Contents of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter attachment Atom Fast 8816 - 1 pc. Packing box 1 pc. Carrying case - 1 pc.
Produced in: Moscow, Troitsk
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
General purpose exhaust cabinet LAB-PRO SHV 90.84.230 SS
General purpose exhaust cabinet LAB-PRO SHV 90.84.230 SS
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather on the top panel: LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the back panel to the center of the flange is 170mm) easily removable exhaust canopies 3 levels of exhaust (lower, side and front) counterweights are placed in the front pillars-pylons and are easily serviced by the rear and upper panels – polypropylene The frame base is a collapsible frame made of a rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel is a metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
EVRAZCOMB – TSO
EVRAZCOMB – TSO
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters Measurement range: from 1 to 2000 ppm O2 - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the level of oxygen activity) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
Measuring recorder IS-203.4
Measuring recorder IS-203.4
from 36 000 ₽
The IS-203.4 meter-recorder is designed to measure and convert analog signals from primary converters (temperature, pressure, humidity, etc.) into the value of the measured physical quantity, as well as register measuring information in the device's memory and then transfer it to a computer (RS 485 or USB) for visualization in the form of tables and graphs. The meter-recorder is a microprocessor-based meter equipped with a non-volatile storage device and a real-time clock. The device has the ability to work as a network device (up to 20 network devices at the same time) or stand-alone with subsequent connection to computers (laptop) for reading data. The operating conditions of the meter IS-203.4 Ambient temperature, °C: -30...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7.
Produced in: Kolomna, Moscow region
2ZVE-400R Electromechanical vacuum shutter with gearbox
2ZVE-400R Electromechanical vacuum shutter with gearbox
The 2ZVE-400R vacuum shutter with electromechanical drive equipped with 400mm conditional passages is designed to overlap vacuum systems in the range of operating pressures from 1x10-6 to 1.07x105 Pa (0.75x10–8 to 800 mm Hg). The 2ZVE-400R shutter is pendulum-type. The 23VE-400R shutter is manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69. The working environment is air and non–aggressive gases. It is not intended for use in fire hazardous and explosive industries. The 23VE-400R shutter meets the requirements of technical specifications TU 3648-040-00218526-2003. According to the method of protecting a person from electric shock, it belongs to Class I electrical equipment according to GOST 12.2.007.0-75.
Produced in: Kazan
Laboratory electronic thermometer LTA-MT
Laboratory electronic thermometer LTA-MT
LTA-MT provides an error of ±0.2 °C in the measured temperature range from -196 to +300 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
High-frequency signal generator G4-232
High-frequency signal generator G4-232
A remote frequency converter with coaxial output extends the frequency range up to 37.5 GHz. The included coaxial-waveguide transitions and the ability to connect a small frequency converter directly to the user's device expand the scope of the device. The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications The frequency range at the output of the base unit is from 5 to 20 GHz The frequency range at the output of the frequency converter is from 5 to 37.5 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the signal power level at the output of the base unit is from minus 110 to 13 dBm The range of setting the signal power level at the output of the frequency converter is from 0 to 13 dBm The basic error of setting the reference power level is ± (1.0 – 2.0) dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: LF from 1 Hz to 20 kHz RF from 10 Hz to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): LF from 1 Hz to 200 kHz RF from 10 Hz to 10000 kHz - the main error of the frequency deviation setting is ± (5 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the basic error of setting the amplitude modulation coefficient: internal ± (0.15 M + 0.2)% external ± (0.20 M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10°C to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 20 kg
Produced in: Moscow
EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
Purpose: Measurement of hydrogen in molten metals Scope of application: Induction furnaces, ladle furnace units, vacuum cleaners, casting ladles of various types, intermediate ladles, crystallizers Measuring range: from 0.5 to 14 ppm H2 Accuracy: 0.5 to 3ppm - 0.1ppm H2 3.0 to 14ppm - 3% H2 Measurement time: up to 60 seconds Reproducibility of results: 0.3% Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: 0.01 to 2.00% carbon Accuracy: 0.01 %
Produced in: Lipetsk
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
The result of determining the energy distribution of the neutron radiation flux density is used to calculate such quantities as: - integral neutron flux density; - the average energy of neutron radiation in the spectrum; - the average neutron radiation energy by dose; - dose equivalent per unit flow density; - dose equivalent; - effective dose. ▪ Methodological support of measurements ▪ It is possible to supply an expanded set of polyethylene retarder spheres with diameters: 3,5”; 4,5”; 5”; 7”; 9”; 9,5”
Produced in: Belarus, Minsk
Support-rotary device OPU-1
Support-rotary device OPU-1
Technical specifications: Azimuth rotation angle from 0° to 360° with vernier ± 15° The angle of rotation according to the angle of the place from minus 30° to plus 90° The angle of the polarization plane is from minus 5° to plus 95° The installation height of the axis of the orientation mechanism is from 1.15 to 2.1 m in the version of USHIAI.301554.001 and from 1.4 to 2.35 m in the version of USHIAI.301554.001-01 Smooth adjustment of the height of the axis of the orientation mechanism 0.15 m In terms of strength under climatic and mechanical influences, the tripod complies with the norms of group 6 GOST 22261-94 The overall dimensions of the tripod are - 2080x2080x2100 mm (USHIAI.301554.001), – 2080x2080x2350 mm (USHIAI.301554.001-01) (shown in the unfolded state at maximum height. The size Ø2080 is the diameter of the circumscribed circle along the vertices of the triangle occupied by the tripod on a horizontal platform) Operating conditions of the tripod: ambient temperature from minus 50 to plus 60oC Tripod weight – 20.5 kg (USHIAI.301554.001), 21.5 kg (USHIAI.301554.001-01)
MNIPI
Minsk
Produced in: Belarus, Minsk