Search

14 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    All filters
    • 3
      Applying
    • 6
      Names
    • 1
      Manufacturer
    • Made in
    • 0
      Additional
      View:
      14 products
      EVRAZOXY Universal
      EVRAZOXY Universal
      Purpose: Measurement of oxygen activity in molten steel Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measurement range: from 1 to 2000 ppm O2 - metal oxidation from 1000 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3°C at 1554°C; (from 5 to 10) mV (depending on the level of oxygen activity) Measurement time: 8 sec Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, cardboard Type of HCX: B, S, R
      Produced in: Lipetsk
      EVRASAMP ESC Sampling with low carbon content
      EVRASAMP ESC Sampling with low carbon content
      Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Type of sampler: Ceramic sampler with an elongated leg Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
      Produced in: Lipetsk
      EVRAZCOMB – 3 in 1
      EVRAZCOMB – 3 in 1
      Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRASAMP ES Sampling of the required configuration
      EVRASAMP ES Sampling of the required configuration
      Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Sampler type: with a ladder - oval shape, circle Operating temperature range (depending on the type of sampler): from 1460°C to 2020°C Selection time: from 3 to 5 seconds Tube length: from 100 to 1500 mm (other length is possible on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
      Produced in: Lipetsk
      EVRAZCARB For measuring the carbon content in steel
      EVRAZCARB For measuring the carbon content in steel
      Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: from 0.01 to 2.00% carbon Accuracy: 0.01 %
      Produced in: Lipetsk
      EVRASAMP ESU Sampling of the required configuration
      EVRASAMP ESU Sampling of the required configuration
      Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Induction furnaces, steel ladles, metal finishing plants, filling ladles, etc. Sampler type: Sand shape – sample thickness 6 mm, 8 mm, 10 mm, 12 mm Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
      Produced in: Lipetsk
      EVRAZTEMP Submersible thermocouples for one-time use.
      EVRAZTEMP Submersible thermocouples for one-time use.
      Purpose: Measurement of molten metal temperature Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, blast furnaces, casting buckets Measuring range: from 700°C to 1800°C Accuracy: 0 + 3°C at 1554°C Measurement time: 4 sec Tube Length: from 100 to 1800 mm (other length is possible on request) Slag Cap: Steel, uncapped, aluminum Splash protection: Refractory fiber Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
      EVRAZ HYDRO Submersible probe For measuring the hydrogen content in steel
      Purpose: Measurement of hydrogen in molten metals Scope of application: Induction furnaces, ladle furnace units, vacuum cleaners, casting ladles of various types, intermediate ladles, crystallizers Measuring range: from 0.5 to 14 ppm H2 Accuracy: 0.5 to 3ppm - 0.1ppm H2 3.0 to 14ppm - 3% H2 Measurement time: up to 60 seconds Reproducibility of results: 0.3% Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: 0.01 to 2.00% carbon Accuracy: 0.01 %
      Produced in: Lipetsk
      EVRAZCOMB – 2 in 1
      EVRAZCOMB – 2 in 1
      Purpose: Temperature measurement and sampling of molten steel. Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1400 to 1800 °C - metal temperature Accuracy: 0 + 3°C at 1554°C The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRAZCOMB – TSC
      EVRAZCOMB – TSC
      Purpose: Temperature measurement, sampling of molten metal Scope of application: Oxygen converters Measuring range: from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRAZCOMB – TSO
      EVRAZCOMB – TSO
      Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters Measurement range: from 1 to 2000 ppm O2 - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the level of oxygen activity) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
      Produced in: Lipetsk
      EVRAZTEMP Submersible thermocouples for reusable use
      EVRAZTEMP Submersible thermocouples for reusable use
      Purpose: Measurement of molten metal temperature Scope of application: Induction furnaces, blast furnaces, casting ladles Measuring range: from 600°C to 1800°C Accuracy: 0 + 3°C at 1554°C Measurement time: 4 sec Tube Length: from 100 to 1800 mm (other lengths are available on request) Slag Cap: Steel, uncapped, aluminum Number of measurements: 5 or more times Type of NSH: B, S
      Produced in: Lipetsk