Universal mobile complex for verification and repair of measuring instruments
Universal mobile complex for verification and repair of measuring instruments
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a set temperature level (20-25) ° C in the container body, at an outdoor temperature from minus 40 ° C to 40 ° C. Operating conditions Ambient air temperature from minus 40 to 40 ° C; Relative humidity up to 95 % at tº= 30 ° C; Atmospheric pressure from 84.0 to 106.7 kPa (from 630 to 800 mm Hg); General-purpose power supply: alternating three-phase current with a frequency of (50 ± 1) Hz with a RMS voltage value in each phase (380 ± 38) V. A set of functionally related working standards, special equipment and automation tools allows you to implement complex metrological maintenance of measuring instruments at automated (automated) and non-automated (RM) workplaces
Produced in: Moscow
GAMMA‑RADIOMETERS RCG‑AT1320, RCG‑AT1320A, RCG‑AT1320V, RCG‑AT1320S
GAMMA‑RADIOMETERS RCG‑AT1320, RCG‑AT1320A, RCG‑AT1320V, RCG‑AT1320S
Intelligent spectrometric type detection unit AT1320V: The possibility of radiation monitoring of mushrooms and berries in a 10-liter container box in 20 seconds AT1320S: During the measurements, a preliminary analysis of the radionuclide composition of the sample is carried out. The activity is calculated based on the results of identification of radionuclides present in the controlled sample Methodological support of measurements
Produced in: Belarus, Minsk
Smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory
Smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory
from 10 560 ₽
The smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor, Android program. Operating conditions of the SZPG.150PM smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.150PM smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Calibration capability.
Produced in: Kolomna, Moscow region
Verification module PM-3
Verification module PM-3
The composition of the PM-3 verification module: Frequency comparator CHK7-1011; Universal frequency meter Ch3-86A; Universal voltmeter V7-79; Absorbed power wattmeter M3-108-2; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Generator of test pulses G9-1A; Oscilloscope S1-177; DC power supply B5-79/1; Electronic switchboard of RF signals; AC power source B2-7 (2 pcs.); PC, printer; Basic load-bearing structures (BNC). Technical specifications Measurement ranges of time-frequency parameters of signals: Continuous oscillation frequency from 0.005 Hz to 17.85 GHz Pulse repetition rate from 0.01 Hz to 100 MHz The carrier frequency of the IM signal is from 100 MHz to 17.85 GHz Pulse duration from 10 ns to 1000 s Time interval from 0 to 1000 s Nominal values of the frequency of the studied signals are 2,048; 5,0; 10,0; 10,24 MHz Measurement errors of time-frequency parameters of signals: Frequency of continuous oscillations ± (2,4·10-10 - 4·10-3) Pulse repetition rate ± (2·10-7 - 2·10-3) The carrier frequency of the IM signal is ± 2·10-7 Pulse duration ± (1 - 200) ns Time interval ± (1 - 200) ns The relative deviation of the frequency of the studied signal from the reference frequency ± (5·10-13 - 2·10-12) Frequency of continuous oscillations ± (3·10-11 – 1,1·10-5) Pulse repetition rate ± (2·10-11 – 6·10-5) Carrier frequency of the IM signal ± (3·10-11 – 1,1·10-5) Pulse duration ± (1·10-8 – 7,2·10-4) Time interval ± (2·10-10 – 7,2·10-4) Nominal values of the reference signal frequency ± (2·10-11 – 2,4·10-10) General technical characteristics: The area occupied by the module is 8-12 m2 Weight, not more than 327 kg Power supply voltage from 198 to 242 V frequency (50 ± 0.5) Hz Power consumption, no more than 2400 VA
Produced in: Moscow
Immitance Broadband Analyzer E7-28
Immitance Broadband Analyzer E7-28
Technical specifications: Extended frequency range 25 Hz–10 MHz The basic error is ±0.1 % The level of the measuring signal is 5 mV – 1 V S.K.z. Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Pressure gauge MTIf-100
Pressure gauge MTIf-100
Pressure gauge with a range of measured pressure 0 ... 100 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm
Produced in: Tomsk
Immitance meter E7-30
Immitance meter E7-30
Technical specifications: Wide frequency range 25 Hz–3 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.005 – 1) V RS-232C, USB 2.0 interfaces Mathematical processing of measurements Dimensions, weight: 134x270x320 mm, 4 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
General purpose exhaust cabinet LAB-PRO SHV 120.84.230 KG
General purpose exhaust cabinet LAB-PRO SHV 120.84.230 KG
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the rear panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel – metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Frequency comparator CHK7-1012
Frequency comparator CHK7-1012
The comparator CHK7-1012 has a communication interface with an external personal computer USB 2.0 and application software for an external PC. At the request of the customer, the comparator can be supplied complete with a laptop or tablet computer with installed software.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Anemometer M-95-CM
Anemometer M-95-CM
from 54 789 ₽
Application range: 1.8 ... 55.0 m/s Alarm threshold setting range: wind speed from 12 to 40 m/s The range of setting alarm thresholds in time is from 2 to 5 seconds. Accuracy characteristics: PG±(0.5+0.05V) m/s Device weight: 4.5 kg The average service life is at least 8 years. The anemometer sensor is supplied with heating only. Application conditions: wind speed sensor from -60C to +50C the measuring panel is from -10C to +40C powered by a 220 V network or a DC 12V source. The modification of the M-95-CM "Dome" automatically disables alarm and emergency devices after the time desired by the customer after the weather conditions have improved to a safe level. The wind receiver is metal. Minor design changes are possible that do not remove the device from the approved type. It is possible to supply the device with a computer output (RS-232) on an additional order.
EMPGGO