Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation of control of surface radioactive contamination of personnel RZA-08D
Installation for monitoring radioactive contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta - active substances. Modern and intuitive interface, various versions. Purpose: monitoring the level of contamination of hands, feet (shoes) and clothing of personnel with alpha- and beta-active substances and signaling when exceeding permissible levels; measurement of alpha and beta radiation flux density from the surface of the hands, feet (shoes) and clothing of personnel; measurement of the surface activity of alpha- and beta-emitting radionuclides of hands, feet (shoes) and clothing of personnel.
Doza
Zelenograd
Produced in: Moscow
EPR spectrometer CMS8400 NEO
EPR spectrometer CMS8400 NEO
The CMS8400 NEO is a compact electron paramagnetic resonance spectrometer designed for routine research in physics, chemistry, biology and related scientific fields for direct detection of free radicals and paramagnetic materials. The CMS8400 NEO can be used in both laboratory and industrial settings in the mode of on-line measurements, embedded in technological processes, thus providing control of parameters and reactions in the production process. Additional accessories and adapted software can make the spectrometer an analytical tool and allow to implement new complex applications in medicine, petrochemistry, brewing, sanitary and hygienic control, as well as in other industries.
Produced in: Belarus
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
Small-sized devices for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130). Durable metal case Convenient menu Selective measurement of beta and gamma radiation in mixed fields (AT6130) Measurement of dose rate up to 100 mSv/h (AT6130D) Search mode Headphones for working in noisy environments (on request)
Produced in: Belarus, Minsk
Fume Cupboard for oil paraffin analysis SHVPNK-311
Fume Cupboard for oil paraffin analysis SHVPNK-311
It can be used in laboratories related to oil activities and in research laboratories. Overall dimensions with raised protective screen 1505x800x2270 mm Overall dimensions with lowered protective screen 1505x800x2100 mm The diameter of the exhaust pipe is 200 mm Weight 220 kg Power supply 220 V, 50 Hz, 16 A
Produced in: Tomsk
MTM-01 Three-component small-sized magnetometer - constant magnetic field meter
MTM-01 Three-component small-sized magnetometer - constant magnetic field meter
from 111 500 ₽
The measuring converter of the Earth's magnetic field is made on the basis of magnetoresistive sensors that simultaneously measure the orthogonal components of the magnetic field strength at the control point and the modulus of the intensity vector. At the same time, the magnetometer readings do not depend on the orientation of the measuring transducer in space. The MTM-01 magnetometer is also an effective means of measuring the quality of magnetic protections and screens to ensure the standards of electromagnetic safety of workers and the public during the operation of distribution transformers and electric power plants.
Produced in: Moscow
EVRAZCARB For measuring the carbon content in steel
EVRAZCARB For measuring the carbon content in steel
Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: from 0.01 to 2.00% carbon Accuracy: 0.01 %
Produced in: Lipetsk
Dosimetric control Stand (SDK)
Dosimetric control Stand (SDK)
The dosimetric control stand (SDK) is designed for continuous monitoring of the parameters of the radiation situation in the premises and technological systems of nuclear and nuclear hazardous production enterprises. KFOR can be used as a structural element of the lower level of automated radiation monitoring systems at nuclear power and industrial facilities related to the obtaining, processing, use and storage of radioactive materials.
Doza
Zelenograd
Produced in: Moscow
Second Mark Shaper Module
Second Mark Shaper Module
Pulse duration: ......10-15 microseconds The duration of the leading edge of the pulse:......no more than 20 ns Pulse amplitude: ...... at least 3V at a load of 50 ohms
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
DC power supply B5-83
DC power supply B5-83
The B5-83 DC power supply is designed to provide constant voltage and current to devices and equipment during the development, production, operation and repair of electronic devices. - Allows harsh operating conditions - Wide range of currents and voltages at a maximum power of 200 watts Technical specifications Output voltage setting range from 3 to 300 V Output current setting range from 0.05 to 2 A Electrical output power, not more than 200 watts The main error of the output voltage setting is ± 2 V The main error of setting the output current is ± 0.02 A Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 3 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 10 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 1 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 2 mA) The change in the output voltage in the voltage stabilization mode with a deviation of the ambient temperature in the operating temperature range by ± 10 ° C, not more than ± 250 mV Change of the output current in the current stabilization mode with a deviation of the ambient temperature in the operating temperature range by ± 10 ° C, not more than ± 10 mA Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 350 VA Overall dimensions, mm 240x128x313 Weight, not more than 5.5 kg
Produced in: Moscow
General purpose exhaust cabinet LAB-PRO SHV 120.74.230 KG
General purpose exhaust cabinet LAB-PRO SHV 120.74.230 KG
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) the front anti-spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the rear panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg