Metrology

527 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 196
    Names
    Loading...
  • 54
    Manufacturer
    Loading...
  • 33
    Made in
    Loading...
  • 50
    Additional
    Loading...
View:
527 products
VD-90NP Eddy current flaw detector in the basic configuration
VD-90NP Eddy current flaw detector in the basic configuration
from 295 000 ₽
The principle of operation of the device: The principle of operation of the flaw detector is based on the excitation of eddy currents in the controlled product and the subsequent release of a signal at the output of the converter, the amplitude and phase of which are determined by the secondary field of eddy currents. Design features and advantages of the VD-90NP flaw detector. The device has a small-sized case, which ensures its lightness, ergonomics and allows you to mount it on your belt or on your arm. The measurement is performed using a remote converter connected by a flexible cable. There are several types of converters for eddy current flaw detection of products made of different materials and different geometries. The large and bright display displays the selected operating modes and measurement results in text and graphic form. The VD-90NP is also characterized by: high sensitivity (it detects cracks starting from 0.1 mm in size); dust–and-moisture-proof housing, which makes it applicable for work in the field; large operating frequency range; maximum working clearance up to 10mm; Bluetooth connection; the ability to control products with high surface roughness, up to Rz320 class; light and sound indication of defect detection; wide operating temperature range from –30°C to +50°C; autonomous low-voltage power supply; long continuous operation time from one set of batteries; compliance with the standard GOST R ISO 15549-2009 (ISO 15549:2008). The use of a microprocessor-based hardware and software platform provide it with the following operational characteristics: automatic adjustment when measuring conditions change, including compensating the influence of the gap; built-in calibration modes; saving the measurement results in the internal memory of the device; a large number of stored programs: sets of parameters and measurement modes, both preset and saved by the user so as to repeatedly monitor the same type of products; The Bluetooth 2.0 wireless communication module allows the device to be used in conjunction with an external laptop or mobile device for remote control, transmission of measurement results for further storage, printing, documentation and analysis. Scope of application: The eddy current method is suitable for non-destructive testing and detection of microcracks in products and parts made of any metals and alloys of complex shape, with high surface roughness, through non-conductive coatings, as well as for checking welded joints. The flaw detector can be used to control parts and assemblies of aviation equipment. The VD-90NP eddy current flaw detector is used for quality control and preventive examination of: - components and parts of rolling stock at railway transport enterprises: wheel sets, auto coupler housings, side frames, spring beams, labyrinth rings, pulleys; - pipes, profiles, rods at rolling mills at the output control, and at the input control of consumers of products; - products made of aluminum and titanium alloys with multilayer coatings at enterprises of the aviation and aerospace industry; - cables, beams, critical components of equipment (cranes, lifts) in construction; - main pipelines in order to detect stress corrosion. A wide range of operating temperatures, dust and moisture protection (IP54 degree of protection), autonomous low-voltage power supply, a long time of continuous operation of the device allows it to be used in the field at low temperatures and under precipitation (rain, snow). Basic kit: • 1 electronic unit for the VD-90NP eddy current flaw detector; • 1 Ia5.125.052 (Type-2) eddy current converter; • 1 converter cable; • 1 charger with batteries; • 1 hand strap; • 1 Ia8.896.104 sample with artificial defects; • 1 Ia8.896.035 coating sample; • 1 storage and carrying case; • 1 documentation set.
Produced in: Moscow
Installation of control of surface contamination of personnel RZBA-09D
Installation of control of surface contamination of personnel RZBA-09D
Complete pollution control with maximum efficiency in minimum time. Easy operation, accessible to employees of any qualification. Purpose: determination of the level of radioactive contamination of the surface of clothing, shoes and leather; measurement of the flux density of beta- and alpha-emitting radionuclides measurement of the surface activity of radionuclides Sr-90+Y-90 and Pu-239; detection of gamma radiation during personnel monitoring; alarm and control of personnel passage when exceeding the set levels.
Doza
Zelenograd
Produced in: Moscow
X-RAY DOSIMETER DKR‑AT1103M
X-RAY DOSIMETER DKR‑AT1103M
A unique highly sensitive device for monitoring dose loads on the lens, mucous membranes and skin Spectrum display mode when connected to a PC It is not intended for measuring the natural radiation background
Produced in: Belarus, Minsk
Second Mark Shaper Module
Second Mark Shaper Module
Pulse duration: ......10-15 microseconds The duration of the leading edge of the pulse:......no more than 20 ns Pulse amplitude: ...... at least 3V at a load of 50 ohms
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Sigmed MC-01 Microcentrifuge
Sigmed MC-01 Microcentrifuge
Functionality 1. Centrifugation function (300 - 4000 rpm). 2. Shaking function (forward-reverse rotation with a frequency of 2 sec.). 3. Mixing in the flask (up to 400 rpm). 4. Mixing in a test tube (500 rpm). 5. Full loading: 12 plastic tubes of the Eppendorf type with a volume of 1.5 ml or 2 ml Safety 1. Blocking operation when the lid is open. 2. Stops working when opening the lid. 3. Stops working when the mains voltage disappears; it does not restart when the mains voltage appears again. 4. Automatic shutdown after 60 minutes. 5. Low-voltage power supply (+24V). Ergonomics 1. Simple and intuitive arrangement of controls. 2. RPM or linear g-load are displayed on the readout.
Produced in: Kaluga region, Obninsk
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
Control of individual radiation doses from X-ray and gamma radiation. Together with a reader connected to a PC and specialized application software, they form an effective system for automated control of dose loads on personnel. Silicon Planar Detector Lack of own background Simultaneous measurement of dose loads on internal organs Hp(10) and skin Hp (0.07)
Produced in: Belarus, Minsk
Frequency meters H3-88
Frequency meters H3-88
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 2500 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz Counting time: input A, C – 1, 10, 102, 103, 104 ms; login to – (16•1), (16•10), (16•102), (16•103), (16•104) ms The number of averages. the period of the. vx. signal - 1, 10, 102, 103, 104 Timestamp period – 10-7, 10-6, 10-5, 10-4, 10-3 Borehole measurement at inputs A, C – 1.000001- 999999999 Frequency ratio in channels: A/S and C/A - 0.0001- 999999999; B/S - 0.5 – 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 5•10-8 - for 30 days, ± 10-7 - for 12 months 9 decimal places Overall dimensions (HXHL) - 285x106x345 mm Weight: 4 kg Reference generator: 1x10-7 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
Portable Electrical Laboratory for Cable Damage Detection by Acoustic and Induction method Athlete KAI-1.1001
Portable Electrical Laboratory for Cable Damage Detection by Acoustic and Induction method Athlete KAI-1.1001
Appointment Athlete KAI-1.1001 • Search for a live cable. • Detection of the passage of hidden communications (metal pipelines, cable lines). • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. • The presence of a "Friend-Foe" mode.
Produced in: Kolomna, Moscow region