DC power supply B5-79
DC power supply B5-79
The B5-79 DC power supply is designed to provide constant voltage and current to measuring instruments and equipment during the development, production, operation and repair of electronic devices. Technical specifications Output voltage setting range from 0 to 60 V Output current setting range from 0.2 to 10 A Maximum output power 300W The main error of the output voltage setting is ± 300 mV The main error of the output current setting is ± 100 mA Additional error in setting the output voltage caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0001 · Uust + 1 mV) Additional error in setting the output voltage caused by a change in the load current from 0.9 of the maximum value to zero ± (0.0002 · Uust + 5 mV) Additional error in setting the output current caused by a deviation of the mains voltage from the nominal value by ± 10% ± (0.0002 · Iust + 2 mA) Additional error in setting the output current caused by a change in the load voltage from 0.9 of the maximum value to zero ± (0.0005 · Iust + 5 mA) Instability of the output voltage for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mV Instability of the output current for any 10 minutes during 8 hours of continuous operation, no more than ± 50 mA Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, no more than 500 VA Overall dimensions, mm 240x128x313 Weight, not more than 6.0 kg
Generator G3-131
Generator G3-131
Technical specifications: Frequency range, from 2 Hz to 2 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms , at least 5 V at least 10 V Smooth signal attenuation, at least 20 dB Frequency instability: - in 15 minutes - for 180 minutes, no more than 0.1% no more than 0.5 % Harmonic coefficient: - in the frequency range from 10 Hz to 20 Hz - in the frequency range sv. 20 Hz to 200 kHz - in the frequency range of 200 kHz to 2 MHz, not more than 0.5% not more than 0.2% not more than 1 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Portable Electrical Laboratory for cable damage detection by Acoustic and Induction method Athlete KAI-1.1002 (IDM)
Portable Electrical Laboratory for cable damage detection by Acoustic and Induction method Athlete KAI-1.1002 (IDM)
Appointment Athlete KAI-1.1002 (IDM) • Search for a live cable. • Detection of the passage of hidden communications (metal pipelines, cable lines). • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. • The presence of a "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
Smart probe of relative humidity and temperature L=500 mm SSVL.500
Smart probe of relative humidity and temperature L=500 mm SSVL.500
from 15 801 ₽
The smart probe of relative humidity and temperature L=500 mm SSVL.500 is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.500 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.500 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Droplet separator
Droplet separator
The drip collector is designed to remove droplet moisture when sampling air from indoor ventilation systems and is installed in gas aerosol sampling systems. Purpose: removal of droplet moisture from the selected air sample; accumulation of droplet moisture; indication of the level of accumulated moisture; draining the accumulated moisture.
Doza
Zelenograd
Produced in: Moscow
Microphone condenser capsule MK-233
Microphone condenser capsule MK-233
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
EVRAZCARB For measuring the carbon content in steel
EVRAZCARB For measuring the carbon content in steel
Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: from 0.01 to 2.00% carbon Accuracy: 0.01 %
Produced in: Lipetsk
Fischer coulometric Titrator
Fischer coulometric Titrator
from 690 000 ₽
The Fischer titrator is designed to measure the moisture content in non-aqueous media in substances that do not interact with the Fischer reagent, such as petroleum, petroleum products, oils (transformer, turbine, hydraulic, motor, etc.), organic solvents, etc. in accordance with GOST ISO 12937:2000, GOST 24614-81, GOST 33733-2016, GOST R 54284-2010, GOST R IEC 60814, GOST 14870-77, ASTM D 4928-00 (2010), ASTM D6304-07, ASTM D 1533-00, ASTM E 1064-05.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg