Search

3960 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 553
    Names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3960 products
Sensor holder LTA-4DSH14
Sensor holder LTA-4DSH14
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
Produced in: Tomsk
Sliding cabinet LAB-400 TVYA-4
Sliding cabinet LAB-400 TVYA-4
Furniture for laboratory work. Sliding cabinet Length, mm: 400 Depth, mm: 580 Height, mm: 830 PACKAGE CONTENTS case – melamine 16mm thick inner size of the box – 310*470* 120mm roller supports h=60mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Nitrogen generator GA-200-N
Nitrogen generator GA-200-N
from 320 400 ₽
The GA-200-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-200 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-200, the GA-200-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.4 Volume fraction of oxygen is not more than, % vol. 0.6 Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati is at least 200 l/hour (3.33 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 1800 l/hour(30 l/min) Factory setting of the maximum pressure in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than, VA, 100 Overall dimensions (width x depth x height) are not more than, mm, 230x525x510; Weight is not more than 27 kg. Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Exhaust cabinet LAB-M SHV ME 120.74.210 TR
Exhaust cabinet LAB-M SHV ME 120.74.210 TR
Furniture for laboratory work. All-metal exhaust cabinet Working surface: Trespa TopLab 6mm, on a substrate of wood-containing material (plywood 15mm, melamine 16mm). Overall dimensions: Length, mm: 1200 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - metal painted with white powder paint (RAL 9016) guide posts – aluminum profile painted with dark gray powder paint (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
DNA molecular weight markers
DNA molecular weight markers
from 1 600 ₽
DNA marker Step50 plus DNA marker Sky-High DNA marker Step 100 DNA marker Step 100 Long
BIOLABMIKS
Novosibirsk
Produced in: Novosibirsk
Table-sink LAB-1400 COULD
Table-sink LAB-1400 COULD
PACKAGE CONTENTS table top – laminate 1 built–in bowl - polypropylene Attention! It is not recommended to use the inner size of the bowl for work with oil and petroleum products (fuel oil, bitumen, etc.) – 400*400* 300mm cabinet body – melamine 16mm thick
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Pure Hydrogen Generator GVCH-9M
Pure Hydrogen Generator GVCH-9M
from 158 400 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the performance, respectively, is 9 / hour (150 ml/min). Optionally equipped with a reactor for using hydrogen as a carrier gas. Technical specifications Purity of hydrogen in terms of dry gas is about 99.998% Concentration of water vapor at 20 OC and 1atm is no more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 9 l/h The time of setting the operating mode, with the output turned off is no more than 15 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 9 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.015 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 80 VA maximum (at startup) is no more than 100 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Combined mobile laboratory up to 35 kV (ETL-35K)
Combined mobile laboratory up to 35 kV (ETL-35K)
The combined laboratory up to 35 kV (ETL-35K) consists of: 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV. 2. Insulation parameters meter • – Transformation coefficient; • – No-load losses at low voltage; • – Short circuit resistance; • – Voltage and current; • – Power factor; • – Frequency of the measured voltage (current); • – Phase shift angle between voltage and current; • – Measurement of the active resistance of the windings. 3. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 4. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 6. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where pipelines and cables intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
Sandy bathhouse "PB" I2
Sandy bathhouse "PB" I2
from 54 251 ₽
The sand bath "PB" I2 with digital control and an increased heating area of 260x510 mm is designed for heat treatment of samples, evaporation and laboratory analysis. Optionally, the product can be equipped with a shutdown timer.
Produced in: Tula
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
The AP-35 analyzer is a fully automated analytical complex designed for continuous X-ray fluorescence analysis of the chemical composition of slurries and solutions in flow. The instrument has a movable software-controlled measuring head with an X-ray tube and fixed spectrometric channels (up to 8), each of which can be set up for any chemical element (from Ca to U). In operation, up to 15 flow cells are measured by the head according to a preset program. Multi channel capability (up to 15 products to be measured). Compatibility with automation systems for sampling, sample delivery, data handling and presentation, data archiving. Link to factory process control system High expressiveness, high analytical precision, low detection limits, reproducibility High reliability. The principle of operation is based on the excited fluorescence produced by the atoms of the material under analysis through the radiation of an X-ray tube. The fluorescence radiation of a particular chemical element is picked up by the crystal analyzer, and then the radiation at a specific wavelength is detected by an X-ray tube detector. The intensity of the recorded fluorescence radiation of a certain wavelength is directly proportional to the mass fraction of the chemical element in the substance under study.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Muffle furnace LF-9/11-G2
Muffle furnace LF-9/11-G2
Design features: Programmable microprocessor; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x150x290 mm Overall dimensions, WxHxD, not more than 525x625x620 mm Rated supply voltage, 220 V Rated power, W 5500
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K2-EDTA, 1ml, 13×75mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K2-EDTA, 1ml, 13×75mm, purple, PET, pack.100 pcs,
from 690 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region