Search

3941 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3941 products
EVRAZOXY For high oxidation
EVRAZOXY For high oxidation
Purpose: Measurement of oxygen activity in molten steel Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, blast furnaces, casting buckets Measurement range: from 50 to 2000 ppm O2 - metal oxidation from 1000 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3°C at 1554°C; (from 5 to 10) mV (depending on the level of oxygen activity) Measurement time: 8 sec Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
IR Laser Module KLM-D980-x-5 980nm
IR Laser Module KLM-D980-x-5 980nm
from 4 314 ₽
Laser modules of the KLM-D980-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
NV-1200 Lv High laboratory tables (1090×700×850)
NV-1200 Lv High laboratory tables (1090×700×850)
from 14 088 ₽
NV-1200 Lv are laboratory tables with a metal frame and a tabletop width of 1090 mm. They are designed for standing work (table height — 850 mm). The NV-1200 tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a 2 mm PVC edge, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table when assembled (W×D ×H): 1090×700×850 mm. The working surface for your tasks We offer laboratory tables with various working surface materials. Version: Countertop NV-1200 LLv: Laminate. An inexpensive solution, suitable for school chemistry and physics classrooms, office work, placement of devices. NV-1200 LSPv: Chemically resistant plastic. A good choice for training workshops, analytical and medical laboratories. It does not tolerate high temperatures, heating devices should not be placed on the surface. NV-1200 LKv: Porcelain tile. A practical solution for most chemical, biological, medical laboratories and workshops. You can put drying cabinets, baths and other heating devices on it. NV-1200 LPv: Polypropylene. A specialized solution for chemical laboratories working with inorganic solvents. NV-1200 LNv: Stainless steel. Stainless steel is well suited for biological or medical laboratories, but it is not recommended for use in chemical laboratories. It has limited resistance to short-term exposure to concentrated mineral acids and alkalis and is destroyed by prolonged exposure to concentrated acids. Advantages of NV-1200 Lv tables An inexpensive solution for laboratories that value the reliability and durability of furniture; Suitable for small rooms; Heating plates or baths can be placed on the granite surface resistant to high temperatures; It is convenient to work while standing: the height of the working surface is 85 cm. Application of NV-1200 Lv tables Tables of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in scientific and educational workshops, in chemistry classrooms, quality control centers, medical organizations and many others.
NV LAB
Moscow
Produced in: Moscow, Moscow region
CRYO-VT-11 Low-temperature liquid thermostat
CRYO-VT-11 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 300 W at +20 °C. An internal bath with a volume of 17 liters and a depth of 250 mm. Operating temperature range -30...+100 °C. Overall dimensions 400x690x585 mm The open part of the bath is 140x190 mm Bath depth 250 mm Weight 50 kg Power consumption 3.5 kW.
Produced in: Tomsk
Vacuum tube MiniMed with coagulation activator and separation gel, 3ml,13*100 mm, yellow-orange, PET,pack.100
Vacuum tube MiniMed with coagulation activator and separation gel, 3ml,13*100 mm, yellow-orange, PET,pack.100
from 1 250 ₽
Test tubes are used for blood sampling in biochemistry and immunology. During centrifugation, the gel forms a strong barrier for 48 hours between the clot and the serum. The gel tubes must be centrifuged no later than 2 hours after blood collection. Material for research............... blood serum Scope of application............................ serum research in biochemistry, immunology Centrifugation.............................. 1500-2000 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Copper Transceiver SFP 10/100/1000Base-T
Copper Transceiver SFP 10/100/1000Base-T
from 2 175 ₽
Receiving and transmitting modules for electrical communication lines in SFP metal cases with separate optical input/output for an RJ-45 type electrical connector to transmit the signal over two optical fibres.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
MKS‑AT6101DR SPECTROMETER (STATIONARY VERSION)
▪ Measurements without sampling in geometry 4π ▪ Intelligent detection unit in an airtight container ▪ The possibility of further detailed processing of the measured data using specialized software
Produced in: Belarus, Minsk
SRK‑AT2327 ALARM METER
SRK‑AT2327 ALARM METER
Building a flexible and reliable multi-channel system Independent measurements on each channel in a wide range of gamma and neutron radiation dose rates and neutron and beta particle flux densities Audiable and light alarms High reliability and self-control Software that allows you to display on the PC monitor the current radiation situation in the controlled area Data logging Backup power supply The possibility of integration with external security systems
Produced in: Belarus, Minsk
BNTI Stand-05-04- P
BNTI Stand-05-04- P
It is designed for installation under a liquid bath BNTI-05-04. Ir provides additional convenience during testing. The wheels make it easy to move the bathhouse when needed. Overall dimensions 790x650x325 mm
Produced in: Tomsk
Viton jumper hose 10/14
Viton jumper hose 10/14
For thermostats operating at high temperatures and filled with an ICP coolant, a viton hose with a cross section of 10/14 should be used as a jumper hose.
Produced in: Tomsk
MF-23IM Flaw detection magnetometer
MF-23IM Flaw detection magnetometer
from 193 200 ₽
The MF-23IM flaw detection magnetometer allows you to determine the compliance of the ratio of the tangential and normal components of the magnetic field strength during magnetic particle testing using both the applied field method (AFM) and the remanent magnetization method (RMM) in accordance with the requirements of current regulatory documentation. The MF-23IM flaw detection magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities.

The flaw detection magnetometer is included in the State Register of Measuring Instruments (GRSI) under No. 20106-00. The magnetometer (milliteslameter) is also included in the register of measuring instruments, testing equipment and measurement methods used at JSC Russian Railways. The flaw detection magnetometer MF-23IM from the manufacturer is used to measure the parameters of constant, variable (industrial frequency) and pulsed magnetic fields when testing ferromagnetic products using the magnetic particle method, as well as to control the level of industrial interference. Specifications.
Magnetic field induction (strength) measurement range: - constant and variable (amplitude and average values) 0.5…1000 mT (4…8000 A/cm) - pulsed (amplitude value) 2…1000 mT (18…8000 A/cm) Indication of measurement results digital or digital + graphic Indicator liquid crystal display Power supply from 1 PP3 battery Current consumption, mA, no more than 15 Memory capacity for storing results 4080 Communication with a computer via infrared channel Dimensions of the electronic unit, mm, no more than 120x60x25 Weight of the electronic unit with battery, g 150

The minimum dimensions of the Hall transducer for the MF-23IM magnetometer make it possible to measure the induction and magnetic field strength in grooves, grooves, corner transitions, i.e. in those areas of the controlled product that are stress concentrators and the most dangerous from the point of view of crack formation; · Measurement of pulsed magnetizing field with pulse duration from 0.5 ms; · Small measurement error (see technical specifications table) · Compact size and low power consumption;

· The magnetometer has 2 modes for displaying measurement results – digital and graphic). The MF-23IM magnetometer in graphical display mode allows you to detect a demagnetizing pulse by displaying its shape and amplitude on a graphic display, as a result of which changes can be made to the magnetization circuit in a timely manner. · The software of the MF-23IM magnetometer allows you to flexibly configure not only the response thresholds, but also the time base, which allows you to tune out false indications caused by reverse emissions of the magnetic field or electromagnetic interference from operating power equipment (magnetizing devices or magnetic particle flaw detectors).

· Determination of the effective magnetization region, within which the tangential component of the magnetic field strength is sufficient for magnetic particle testing, and the ratio of the normal and tangential components of the magnetic field strength is less than or equal to 3. · Checking the mode of magnetization/demagnetization of test objects for compliance with the methodology/technological instructions for magnetic particle testing for a given object.

BASIC SET: Electronic unit Converter 1 Converter 2 Caliber PP3 battery CD with program Case Flaw detection magnetometer MF-23IM. Passport
Produced in: Moscow
Metolab 502 Vickers Hardness Tester
Metolab 502 Vickers Hardness Tester
The stationary METOLAB 502 hardness tester is a modification of the METOLAB 501 series device, equipped with a display and a digital micrometer that allows you to automatically read values without the need for conversion tables. The device also automatically calculates the hardness of the samples. The METOLAB 502 microhardometer is designed to measure the hardness of various samples and products (steels, cast iron, non-ferrous metals and soft alloys) according to the Vickers (HV) and Knup (HK) scales in full compliance with GOST R ISO 6507-1-2007. The device has high accuracy, performs measurements in a wide range and with high repeatability. The stationary automatic METOLAB 502 hardness tester is included in the State Register of Measuring Instruments of the Russian Federation (GRSI) under the number 66668-17 and comes with a certificate of primary verification (on request). Distinctive features of the stationary METOLAB 502 Micro-Vickers hardness tester: Built-in digital micrometer that allows you to automatically read readings without the need for translation tables; Automatic hardness calculation; Simple and intuitive control of the device, fully Russified menu; Wide range of measured values – from 5 to 2500 HV; A wide range of applied test loads - 0.09807 N (10 g), 0.2452 N (25 g), 0.4903 N (50 g), 0.9807 N (100 g), 1.961 N (200 g), 2.942 N (300 g), 4.904 N (500 g), 9.80 N (1 kg); Large and bright LCD display. Basic delivery package: Stationary METOLAB 502 Micro-Vickers Hardness Tester; Standard hardness sample – 2 pcs.; Flat desktop; Large flat desktop; V-shaped desktop; Micrometer; Diamond indenter with an angle of 136°; User Manual.
Metolab
Moscow
Produced in: Moscow