Dosimeter-radiometer ISS-17D "Finch"
Dosimeter-radiometer ISS-17D "Finch"
Purpose: measurement of the power of ambient dose equivalent (MAED) and ambient dose equivalent (ED) of photon radiation; operational search for sources of ionizing radiation and radioactive materials; measurement of the flux density and fluence of alpha and beta radiation; measurement of surface alpha and beta activity; measurement of the ambient dose equivalent (MAED) power of neutron radiation.
Doza
Zelenograd
Produced in: Moscow
Electronic explosion-proof thermometer ExT-01/1
Electronic explosion-proof thermometer ExT-01/1
The thermometer sensor ExT-01/1 is made in the form of a thin detachable probe without an extension cable. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Belgorod, Tomsk
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 120.86.230 PP
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 120.86.230 PP
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) front anti–spill side - polypropylene working surface - polypropylene 15mm thick removable plate 600*600mm with a ceramic granite work surface for placement heating plates (1 pc.) 2 dependent lifting screens filled with transparent PVC, 5mm thick in a polypropylene frame in the lower screen – sliding doors made of transparent PVC with a thickness of 5mm lifting 0-780mm, does not change the dimensions of the cabinet when lifting counterweights are placed in the front pillars-pylons and are easily serviced upper fixed screen – polypropylene inner part the working box is a fully sealed polypropylene capsule with a back wall washing system, a drainage channel and a polypropylene pipe for cold water 3 levels of hoods easily removable polypropylene exhaust canopies polypropylene drain sink on the top panel are placed: LED dust- and moisture-proof lamp (2x10W IP65) separated from the workspace by transparent PVC switching box with automatic emergency power off 16A flange with damper plug for air inflow d=200mm flange with aspiration collector for air outflow d=250mm (distance from the rear panels up to the center of the flange – 155mm) cabinet ventilation system
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Central Heating Unit N (CHU-N) Kit
Central Heating Unit N (CHU-N) Kit
It is designed to control the excess pressure during the crimping of pipelines before putting them into operation, as well as during scheduled system health checks. The devices are registered in the State Register of Measuring Instruments for No. 30414-11, No. 43646-10 and are approved for use in the Russian Federation. Features of the CHU-N kit Carrying out pressure testing before the start of commissioning allows you to identify possible defects in seams and pipes, ensuring their tightness and reliability of insulation. The kit is designed to work in the field in order to record and archive the measured results to identify possible defects. The CHU-M kit is a portable complex with autonomous power supply.
Produced in: Kolomna, Moscow region
Installation for measuring the parameters of the air flow multichannel USPVM
Installation for measuring the parameters of the air flow multichannel USPVM
The installation is intended for use in gas-aerosol emission control systems in order to determine the volumetric air flow in ventilation systems by measuring the linear air flow velocity at local points of the dimensional section, as well as for measuring air temperature and humidity at local points. The measuring system of the installation complies with GOST 12.3.018-79 (SSBT. Ventilation systems. Methods of aerodynamic tests).
Doza
Zelenograd
Produced in: Moscow
Oilman's Kit
Oilman's Kit
from 58 491 ₽
It measures temperature when checking the quality of fuel in samplers. •
Produced in: Moscow
Smart surface probe  L=300 mm SZPV.300P with built-in flash memory
Smart surface probe L=300 mm SZPV.300P with built-in flash memory
from 14 352 ₽
The smart surface probe L=300 mm SZPV.300 is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPV.300 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPV smart probe.300 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmission of data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Universal frequency meter Ch3-89
Universal frequency meter Ch3-89
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 150 MHz Frequency of video pulse signals (inputs A, B) 0.001 Hz - 100 MHz Frequency of continuous sinusoidal oscillations (input C) (0.1 - 1) GHz Frequency of continuous sinusoidal oscillations (input D) (1 - 37.5) GHz Carrier frequency of a continuous signal with frequency modulation (FM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz-100 kHz; frequency deviation from 10 kHz to 10 MHz Carrier frequency of a continuous signal with amplitude modulation (AM) (input D) Fh = (1 - 18) GHz, Fm = 100 Hz - 100 kHz; AM factor up to 100% Carrier frequency of a continuous radio pulse sequence (IM) signal (input D) Fn = (1-37.5) GHz, from 0.15 microseconds to 1ms, Fsl from 100 Hz to 3 MHz, from 2 to 103 Pulse duration 10 ns – 0.1 s Time interval from -10 to 10 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Phase difference of two synchronous sinusoidal signals from minus 360° to 360° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 0.36° (from 1 kHz to 1 MHz) ± 3.6° (above 1 MHz) Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 7.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) (0.03 - 1.0) V •for sinusoidal and IM signals (input D) 10 MW (from 1 to 8 GHz); 40 MW (sv. 8 to 18 GHz); 50 MW (sv. 18 to 37.5 GHz). The nominal frequency value of the reference quartz oscillator is 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 100 VhA Overall dimensions, mm 496x174x459 Weight, not more than 16 kg
Produced in: Moscow
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
PKE-A Energy Tester
PKE-A Energy Tester
The devices are designed for: measurements and registration of the main indicators of the quality of electrical energy established by GOST 32144-2013 (GOST R 54149-2010) with registration of protocols according to GOST 33073-2014; measurements and registration of the main parameters of electrical energy in single-phase and three-phase electrical networks (including the effective values of voltages and currents with sinusoidal and distorted curves; active, reactive and full electrical power); measurements of parameters of secondary circuits (load capacity of measuring transformers and voltage drop) in electric energy metering systems and electric energy losses in power supply lines. functional test and verification of connection of meters of active and reactive power and energy, energy measuring converters of voltage, current at the places of their operation; functional test and verification of the connection of single-phase and three-phase electric energy meters without breaking current circuits to detect theft of electricity; measurements of electricity losses in the power supply line. The PKE-A energy tester provides registration with subsequent transfer to a personal computer (PC) of statistical data on the PKE: Values of the PCE according to GOST 30804.4.30 (GOST P 51317.4.30) and GOST 30804.4.7 (GOST P 51317.4.7) with a registration depth of 512 days; Values and durations of voltage dips and overvoltages; Values of the short-term dose of flicker; Parameters of the electrical network and vector diagrams with the depth of registration: - 24 hours for averaging time of 3 s, - 200 days for averaging time of 10 min. The program "Energy Monitoring ES" provides the formation of quality control protocols in the form of GOST 33073-2014.
Marsenergo
Saint Petersburg
Produced in: Saint Petersburg