Search

10 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 7
    Applying
  • Names
  • 4
    Manufacturer
  • 4
    Made in
  • 5
    Additional
View:
10 products
Non-pressure hybrid flow meter-counter Volga Triton
Non-pressure hybrid flow meter-counter Volga Triton
from 300 000 ₽
The Volga Triton pressure-free hybrid flow meter is designed to measure the volumetric flow of liquid in water ducts with a pressure-free and combined pressure-free flow mode. The submerged primary speed converter operates on the basis of the Doppler effect, emitting an ultrasonic signal towards the flow and receiving an echo reflected from particles in the flow with a frequency different from the frequency of the emitted signal. This frequency shift is called the "Doppler Shift" and it is proportional to the flow rate. A non-contact ultrasonic primary converter VBN-DG-01 or any other third-party liquid level converter with a unified current output of 4-20 mA can be used as a depth meter: radar, hydrostatic or ultrasonic. The volumetric flow rate is determined both by the "area-speed" method and by MI2220-2013, depending on hydraulic conditions. In non-contact (radar) mode, the Volga Triton flowmeter is designed to measure the volumetric flow rate of a liquid in a non-pressurized flow mode. The flow meter can be used as part of waste water metering units in non-pressure (gravity) sewage systems, open irrigation and reclamation channels, open or underground derivational non-pressure water pipelines of hydropower facilities, diverting supply and recirculation water pipelines of thermal power and other hydraulic structures with a non-pressure flow regime. The measurement technology is based on a non-contact radar method for measuring surface flow velocity and a non-contact ultrasonic/radar method for measuring water level. As a water level meter, both the proprietary ultrasonic level sensor BP-G-01 and third-party sensors connected via unified digital or analog interfaces, for example, VEGAPLUS, can be used. The pressure-free hybrid flow meter "Volga Triton" became the winner of the International Environmental Award EWA Award 2021 in the nomination Best technology. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters VBN-DS-01 Primary speed converter for medium and large water pipelines VBN-DS-02 Combined primary speed and depth converter for medium and small aqueducts VBN-DS-03 is a combined low-profile primary speed and depth converter for small aqueducts. VBN-DG-01 - contactless ultrasonic primary transducer - depth meter Pipe sizes Du, mm: 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 6000 mm
Produced in: Moscow
Acoustic ultrasonic flow meter Volga ML
Acoustic ultrasonic flow meter Volga ML
from 400 000 ₽
The flow meter is fully developed by Russian specialists in the field of acoustics, hydraulics and electronics, and is designed to measure the volumetric flow rate and volume of water in pipelines, mainly medium and large, under pressure, non-pressure and combined (pressure-free) flow modes. The flowmeter is based on ultrasonic "time-pulse" multipath technology for measuring the flow velocity in the measuring range. In addition, depth sensors (primary transducers) - hydrostatic, radar contactless, ultrasonic underwater or ultrasonic contactless - are used to measure the flow in water ducts with a combined or non-pressure flow mode. In the presence of deposits affecting the shape and area of the live section of the flow, sediment level sensors are used. Secondary converter It is available in both stationary (~220 V) and portable versions with autonomous power supply. Primary converters Inset and overhead primary converters from the inside allow you to place the measurement gate on any water pipe made of any material, taking into account design features. Pipe sizes Du, mm: 200, 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, up to 15000 mm The Volga ML acoustic ultrasonic flowmeter is registered as a type of measuring instrument in the Federal Information Fund for Ensuring the Uniformity of Measurements for No. 78414-20 (MP 2550-0361-2019). The Volga ML acoustic ultrasonic flow meter has been recognized as the winner in the nomination Best Technology of the International Environmental Award EWA Award 2020.
Produced in: Moscow
LEI 0686 Ready buffer solution
LEI 0686 Ready buffer solution
Issued according to specifications 20.59.52-003-51284861 -2017 They are used as reference solutions for transmitting the pH scale of aqueous solutions during calibration and adjustment of pH meters of the 2nd-class accuracy and below, by direct measurement.
Produced in: Moscow
Installation for obtaining analytical quality water UPVA-25
Installation for obtaining analytical quality water UPVA-25
from 194 000 ₽
Capacity, l/h 25,0 (-10%) Purpose preparation of distilled water of type 2 according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 2.7 kW 220V (stainless steel) – 6 pcs. The quality of the produced water GOST 52501-2005 "Water for laboratory analysis", FS.2.2.0019.18 "Water for injection" Type of current, frequency, three-phase alternating voltage, 50 Hz, 380 V Power consumption, kW 16.3 Overall dimensions (L×W×C), mm 660x550x760 Weight, kg 50,0
Livam
Belgorod
Produced in: Belgorod
Installation for obtaining analytical quality water UPVA-5
Installation for obtaining analytical quality water UPVA-5
from 110 000 ₽
Capacity, l/h 5.0 (-10%) Purpose preparation of distilled water of type 2 according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 3.5 kW 220V (stainless steel) – 1 pc. The quality of the produced water GOST 52501-2005 "Water for laboratory analysis", FS.2.2.0019.18 "Water for injection" Type of current, frequency, voltage alternating single-phase, 50 Hz, 220 V Power consumption, kW 3,6 Overall dimensions (L×W×C), mm 424x417x454 Weight, kg 20,0
Livam
Belgorod
Produced in: Belgorod
Installation for obtaining analytical quality water UPVA-15
Installation for obtaining analytical quality water UPVA-15
from 170 000 ₽
Capacity, l/h 15,0 (-10%) Purpose preparation of distilled water of type 2 according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 3.0 kW 220V (stainless steel) – 3 pcs. The quality of the produced water GOST 52501-2005 "Water for laboratory analysis", FS.2.2.0019.18 "Water for injection" Type of current, frequency, three-phase alternating voltage, 50 Hz, 380 V Power consumption, kW 9,1 Overall dimensions (L×W×C), mm 550x500x625 Weight, kg 39.0
Livam
Belgorod
Produced in: Belgorod
Installation for obtaining analytical quality water UPVA-5-1
Installation for obtaining analytical quality water UPVA-5-1
from 312 000 ₽
water type I: 5.0, water type II: 5.0 Purpose obtaining super pure type 1 water according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 3.5 kW 220V (stainless steel) – 1 pc. The quality of the produced water according to the requirements for type I and II water according to GOST 52501-2005 "Water for laboratory analysis" and the articles of the FS.2.2.0019.18 "Water for injection" Type of current, frequency, voltage variable single-phase, 50 Hz, 220 V Power consumption, kW 3,6 Overall dimensions (L×W×C), mm 670×470×490 Weight, kg 35.0
Livam
Belgorod
Produced in: Belgorod