Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Universal reader UZS-01D / UZS-02D
Universal reader UZS-01D / UZS-02D
Purpose: to provide bidirectional data exchange with individual dosimeters DKG-05D, DVS-02D.
Doza
Zelenograd
Produced in: Moscow
Smart probe of relative humidity and temperature L=150 mm SSVL.150P with built-in flash memory
Smart probe of relative humidity and temperature L=150 mm SSVL.150P with built-in flash memory
from 13 740 ₽
The smart probe of relative humidity and temperature L=150 mm with a built-in flash memory is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.150P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.150P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Continuous measurement of temperature in the industrial area
Continuous measurement of temperature in the industrial area
Appointment: the continuous measurement system allows for continuous measurement of the heating temperature of the industrial bucket, to improve the stability and reliability of measuring the temperature of liquid metal. Due to the fixed measurement position, the system eliminates errors due to the human factor. This method of measuring temperature was researched and invented on the theory of an absolutely black body. The principle of the temperature measurement system is the immersion of a temperature probe into molten steel to determine the temperature. The temperature probe made of an absolutely black body is designed in a special way to receive an infrared radiation signal corresponding to the temperature of molten steel. Scope of application: Intermediate bucket Measuring range: Warming up the promkovsh: from 800°C to 1400°C; Molten steel: from 1400°C to 1600°C Accuracy: Preheating of the promkovsh 7 ° C; Molten steel: 3 ° C Response time: Hot response time 75 sec; Cold response time 4 min Measuring probe length: 964mm, 1100mm Durability of measuring probes: 12 hours, 24 hours, 48 hours Number of thermal shocks: up to 5 times
Produced in: Lipetsk
Measuring recorder IS-203.2.0
Measuring recorder IS-203.2.0
from 28 152 ₽
The meter-recorder IS-203.2 is a microprocessor-based meter designed to measure temperature. Equipped with a non-volatile storage device and a real-time clock. The device has two measuring channels. The measurement results are stored in the non-volatile memory with a volume of 15,000 measurements per channel. The operating conditions of the meter IS-203.2.0 Ambient temperature, ° C: -20...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7. Scope of application of the meter IS-203.2.0 Control of technological processes in various industries, including: utilities, construction, food and pharmaceutical industries, agriculture, etc. Warehouses (grocery, industrial, pharmaceutical, etc.). Transportation (grocery, industrial, pharmaceutical, etc.). Functionality of the meter IS- 203.2.0 Temperature measurement by external sensors. Saving the measurement results in the device memory. Indication of the results of current measurements, time, channels included, interval between measurements, free memory of the device, battery capacity, serial number of the device, time of the next measurement. Operational start and stop of the measurement process. Data transfer to a PC via a COM port or USB.
Produced in: Kolomna, Moscow region
Laboratory electronic thermometer LTA-NT
Laboratory electronic thermometer LTA-NT
LTA-HT provides an error of ±0.05 °C in the range of measured temperatures from -50 to +300 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Universal frequency meter Ch3-92
Universal frequency meter Ch3-92
The frequency meter is able to work both independently and as part of automated measuring systems with interfaces such as USB or RS-232. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (0.3 – 37.5) GHz Pulse duration 10 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Frequency measurement resolution 2x10-10 s/Rng The range of setting the trigger levels (inputs A, B) from minus 2.5 to 2.5 V The error of setting the trigger levels (inputs A, B) ± 0.05 V Input signal level: • for sinusoidal signal (inputs A, B) (0.03 - 10.0) V • for video pulse signal (inputs A, B) (0.1 - 10.0) V • for sinusoidal signal (input C) 50 MW - 5 MW Input resistance • Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF • Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 12 months Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 299x136x436,5 Weight, not more than 8.5 kg
Produced in: Moscow
Measuring step attenuator D1-29
Measuring step attenuator D1-29
The device replaces the devices for checking the attenuators D1-13A and D1-25. D1-29 is a step attenuator with a range of attenuation from 0 to 110 dB with a step of 10 dB, operating in the frequency range from 0 to 150 MHz. The device consists of a housing with damping cells and a switch with a counting device. The housing contains coaxial input and output connectors, as well as additional connectors "40 dB" and "80 dB", necessary for the verification of the device. Technical specifications Operating frequency range 0 – 150 MHz Difference attenuation setting range (after 10 dB) 0 – 110 dB Input electrical resistance to direct current 50 ± 0.1 ohms The output electrical resistance to direct current when connected to the load input is 50 ± 0.1 ohms 25 ± 0.1 ohms The main absolute error of the difference attenuation setting relative to the 0 dB mark at direct current ± (0.002 - 0.02) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range up to 30 MHz ± (0.004 - 0.9) dB The main absolute error of the difference attenuation setting relative to the 10 dB mark in the frequency range over 30 to 150 MHz ± (0.09 - 3.0) dB The maximum permissible value of the electrical voltage (DC or AC) at the input of the attenuator 3 In the operating temperature range from 5 to 40 ° C Overall dimensions, mm 149x95x149 Weight, not more than 3 kg
Produced in: Moscow
Portable Electrical Laboratory for cable damage detection by Acoustic and Induction method Athlete KAI-1.502 (IDM)
Portable Electrical Laboratory for cable damage detection by Acoustic and Induction method Athlete KAI-1.502 (IDM)
Appointment Athlete KAI-1.502 (IDM) • Search for a live cable. • Detection of the passage of hidden communications (metal pipelines, cable lines). • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. The presence of the "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
General purpose exhaust cabinet LAB-PRO SHV 180.84.230 TR
General purpose exhaust cabinet LAB-PRO SHV 180.84.230 TR
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (22W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the rear panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced Frame base collapsible frame made of rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel - metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory electronic thermometer LT-300-N
Laboratory electronic thermometer LT-300-N
The measurement range is -50...+300 °C. Up to +200 °C resolution 0.01 °C, error ±0.05 °C (Class C according to ASTM E2877). The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 75x80x35 mm Weight 0.2 kg
Produced in: Tomsk
ZVPlE-900 Flat Electric Vacuum Shutter
ZVPlE-900 Flat Electric Vacuum Shutter
The ZVPlE-900 shutter consists of a housing with connecting flanges, a shutter mechanism, a lip seal to ensure the tightness of the drive element, cover, and electric drive. The shutter mechanism consists of a carriage, an upper and lower flap, which are pulled together by springs and balls. The carriage moves along the housing guides on bearings. The ZVPlE-900 shutter is opened and closed both by electric drive and manually using a flywheel. To switch to manual control mode, there is a switching device on the electric drive. The manual drive is used to adjust and regulate the shutter. ZVPlE-900 valves are manufactured in climatic versions UHL (i.e. for moderate and cold climate) and O (i.e. general) 4 according to GOST standard 15150-69.
Produced in: Kazan