Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
Dry Air Compressor KSV-6/450
Dry Air Compressor KSV-6/450
from 195 600 ₽
The oil-free compressor is designed to supply air to laboratory nitrogen and oxygen generators, purge optical systems of laboratory devices with dry air, etc. A feature of the device is the presence of a built-in automatic regeneration system of the air drying filter, which frees the user from routine maintenance. Small dimensions, low noise level, lack of maintenance work allow the compressor to be placed in the laboratory room and make working with it easy. Technical specifications Rated output, reduced to normal conditions is 7.0 l/min Maximum output, reduced to normal conditions is 9.0 l/min The range of the set output pressure is from 1.0 to 6.0 ati Output pressure stability at constant flow rate is not worse than ± 0.2 ati Stability of the output pressure when the flow rate changes from 0.5 to the maximum value is not worse than ± 0.4 ati The dew point of the outlet air at an ambient temperature of 20 ° C and rated capacity is not higher than minus 30 ° C The dew point of the outlet air at an ambient temperature of 20 ° C and maximum performance is not higher than minus 15 ° C Volume of the built-in receiver is 6 l The noise level of the device is not more than 50 db Ready time after switching on is no more than 10 min Power consumption is not more than 600 VA Overall dimensions of the device (width x depth x height) are not more than 230x580x530 mm Weight of the device is not more than 27 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
Optical Transceiver SFP LC/OC-12/STM-4 SFP Transceiver (622Mbps)
Optical Transceiver SFP LC/OC-12/STM-4 SFP Transceiver (622Mbps)
Optical transceivers are in standard SFP metal cases with separate optical input/output for LC type connectors to transmit the signal over two optical fibres.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
HF-250-5 POZIS Pharmaceutical refrigerator
HF-250-5 POZIS Pharmaceutical refrigerator
from 33 050 ₽
Total volume, l. 250 Height, mm 1300 Depth without handle, mm 610 Depth with handle, mm 650 Width, mm 600 Weight, kg., no more 59 Rated power consumption, W 200 Maximum rated power, 220 W Voltage, 220 V Warranty, years 2 Final report on pre-qualification for compliance with the requirements of Good Practice of the EAEU Distribution: yes Cold storage Auto refrigerator defrosting system Temperature in the refrigerator, °C +2... +15 Accuracy of temperature maintenance ±2°C Thermal card: yes Efficiency and energy consumption Electricity consumption, kWh/day, not more than 0.82 Climate class UHL 4.2 (i.e. for moderate and cold climate) Frequency, Hz 50 Approximate dimensions of the product with packaging Net weight of the product, kg 59 Gross weight of the product, kg 63 Volume of packaging, m3 0,557 The length of the package, m 0.65 The width of the package, m 0.63 The height of the package, m 1.36
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
Cultivator KVM-05 (TU 26.51.70-003-63790925-2021 )
from 150 000 ₽
1 supp.
The Europolitest company continues to release its "bestseller" cultivator KVM-05. This cultivator was developed and produced jointly with the Candidate of Biological Sciences prof. Grigoriev and LLC "Omikron", LLC "SFU-System" Krasnoyarsk. Since 2021, due to the reorganization of the production chain, the production of cultivators of the KVM series has been established by Europolitest LLC in the mode of a full production cycle. The thermophilic strain of chlorella algae has been widely used in ecocontrol laboratories, biotests with this test object are by far the most automated biotests that allow reducing time at all stages of work (building up the uterine culture, sample exposure in the biotest, registration of the test function). Cultivator KVM-05 is a long-lived among cultivators of this purpose and a standard of reliability, reproducibility and durability. Used in techniques: - Methodology for determining the toxicity index of nanopowders, products made of nanomaterials, nanopoints, waste and sewage sludge containing nanoparticles by changing the optical density of the Chlorella algae test culture (Chlorella vulgaris Beijer). FR.1.39.2010.09103; MVI 1/25-2010. - Methodology for determining the toxicity of samples of surface fresh, groundwater, drinking water, wastewater, water extracts from soil, sewage sludge and waste by changing the optical density of the chlorella algae culture (Chlorella vulgaris Beijer). MON F T 14.1:2:3:4.10-04 / 16.1:2.3:3.7-04 FR.1.31.2009.06642. - Methodology for determining the toxicity of drinking, natural and wastewater, water extracts from soils, sewage sludge and waste by changing the relative index of delayed fluorescence (OPF) cultures of chlorella algae (Chlorella vulgaris Beijer) HDPE F 14.1:2:4.16-09 / 16.1:2.3.3.14-09.
Evropolitest
Ivanteevka
Produced in: Moscow region
Laboratory electric furnace CHO-34
Laboratory electric furnace CHO-34
from 276 396 ₽
Designation SNO-34 Volume, l 34 Material of the working chamber ceramics Heating 4 sides Power consumption, W, max 10000 Minimum operating temperature, 0C 100
Produced in: Tula
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-S
Electric cabinet vacuum drying SHSV-3,5.3,5.6/2.5-S
This electric vacuum drying cabinet is designed for drying and heating various materials in air and in vacuum at temperatures up to 250 ° C. A viewing window Ø 160 mm is installed in the door. The illumination of the working chamber is provided from the outside. An additional, independent security system is installed in the cabinet, interrupting the supply of the cabinet when operating temperatures exceed.
Produced in: Tula
Water bath WB-6K
Water bath WB-6K
WB series baths can be used for sample evaporation, incubation, defrosting, conduction of chemical reactions. Temperature setting range, oC +35…+95 Temperature error, oC ±1.0 is protected from excess temperature RAINBOW TSR-150S F-C Hydraulic thermostat Supply voltage, V 230+-10% Current consumption 6.5A Power consumption, 1500 W Overall dimensions L x W x H, mm 450 x 325 x 260 Overall dimensions of the bath L x W x H, mm 360 x 300 x 205 Total / engine capacity, 21.9/18.1 l
Produced in: Belarus, Minsk
Multipurpose X-ray diffractometer DRONE-8T
Multipurpose X-ray diffractometer DRONE-8T
The X-ray diffractometer DRON–8T is the flagship model of the line of stationary X-ray diffractometers of JSC IC Burevestnik. It is equipped with a high-precision wide-angle vertical goniometer with an angular reproducibility of 0.0001° and is designed mainly for the study of highly perfect crystalline objects (single crystals, epitaxial films) in high-resolution geometry.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
3VVN1-6M(N) Water ring vacuum pump
3VVN1-6M(N) Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-6M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working organs. The 3VVN1-6M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-6M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
WATER PURIFICATION DEVICES: AQUARIUS DEVICE
WATER PURIFICATION DEVICES: AQUARIUS DEVICE
Water purification in the device is carried out by passing it through a composition of deionization resins and sorbents. Resins and sorbents are located in filter elements placed in a replaceable cassette. The distilled water to be cleaned is poured into the feed tank, the filler neck of which is placed on the upper plane of the device and hermetically sealed with a screw cap. Technical specifications: The specific conductivity of the resulting water, not more than, mkSxcm 0.20 Capacity, at least, l/h 6 Operating time of the replaceable cassette (total volume of purified water), not less than 700 liters Volume of refilled distilled water, l. 1 Power consumption, not more than, VA 20 Overall dimensions (width×depth×height), mm 180×450×380
Produced in: Yoshkar-Ola, Mari El
Vacuum bellows valve
Vacuum bellows valve
Vacuum valves are designed to cut off and seal the elements of the vacuum system, thereby, vacuum valves provide the necessary sequence of pumping and air intake. The vacuum valves presented in this section are mass-produced by NPO Helikon.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-120C-O
Analytical scales VLA-120C-O
from 329 990 ₽
Technical specifications: NIP, g120 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of the permissible error of the scales during verification, ± mg, weighing intervals: from 0.01 g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, not more than 7 Adjusted weights 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg