Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
CRYOCONCENTRATION DEVICES
CRYOCONCENTRATION DEVICES
To determine small concentrations of substances, in some cases it is impossible to do without their concentration in special traps. An example of the need for such concentration is the determination of impurities in permanent gases (Ne, He, H2, Ar, O2, N2, Kr, Xe), the concentration of impurities is less than 1 ppm. Considering that these impurities can be not only hydrocarbons, but also permanent gases themselves, the use of direct detection of impurities by a catarometer is impossible. It is also not always possible to use highly sensitive but expensive detectors (GID, EDD, etc.). TECHNICAL CHARACTERISTICS The volume of the trap is 5 ml. The volume of the Dewar vessel (serial metal thermos) is 1200 ml. The concentration temperature range is from minus 88.6 (ethane) to minus 269 °C (helium). The ability to calibrate the chromatograph from the cylinder without disturbing the gas circuit. The possibility, simultaneously with concentration, to purify the gas intended for purging the trap from impurities (in a similar trap). Overall dimensions, no more than — 290 ×470 × 615 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
Vacuum electric arc furnace for melting special materials VDP-130-7.5
Vacuum electric arc furnace for melting special materials VDP-130-7.5
Residual pressure in the furnace, millimeters of mercury 7,5*10-6 Arc heating method
VakETO
Mosrentgen
Produced in: Moscow
Laboratory scales VLE-8201S
Laboratory scales VLE-8201S
from 154 990 ₽
Technical characteristics: NIP, G8200 Discreteness, g0,1 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5g to 5000g incl. ±500; sv. 5000g to 8200g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 300 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~0.7 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-417a
Circulation thermostat LT-417a
The LOIP LT-417a modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 17 The working fluid is water, silicone oil. Open part of the bath / depth, Mm 360x296/150 Overall dimensions, mm 532x335x350 Weight, kg 14.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Pure Hydrogen Generator GVCH-16A
Pure Hydrogen Generator GVCH-16A
from 325 200 ₽
The characteristics of the device are similar to the GVCH-12A model. The difference is the generator capacity of 16 liters /hour. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1atm is not more than 5 ppm Total hydrogen capacity, reduced to normal conditions is not less than 16 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.03 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 220 VA maximum (at startup) is no more than 250 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 17 kg Operating conditions: ambient temperature is from +10 to +35 °C powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Chamber low-temperature electric furnace with a retractable hearth-20.26.20/5- I2-In
Chamber low-temperature electric furnace with a retractable hearth-20.26.20/5- I2-In
Designation: SNOT-20.26.20/5- I2-In Camera (WxDxH), mm: 2000x2600x2000 Temperature, 0C: 500 Fan: Yes Hearth drive: EL/MECH Door opening: EL/fur Power supply, V: 380 Power, Ru, kW: 130 Class: 2
Produced in: Tula
Oxygen installations
Oxygen installations
An oxygen plant is a set of special equipment designed for the production of oxygen from atmospheric air by short–cycle non-heating adsorption. Composition of a typical oxygen plant: Air compressor Dehumidifier Main Filter Block Air receiver Oxygen Adsorption Generator Oxygen receiver
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Cable searcher with GPS/GLONASS coordinates saving function Success KBI-309K
Cable searcher with GPS/GLONASS coordinates saving function Success KBI-309K
from 109 800 ₽
Description of the cable searcher Success KBI-309K • – Traceroute receiver in the form of a monoblock with a large LCD display. • – The image of the route on the device screen. • – Automatic calculation and display of the depth of the communication up to 10 m, as well as the current in the line. – Built-in GPS\GLONASS module for determining and recording the coordinates of the location of communication. – "Probe" mode for tracing NON-METALLIC communications using an in-tube generator (optional).
Produced in: Kolomna, Moscow region
IR Laser Module KLM-A980-5-5 980nm 5mW
IR Laser Module KLM-A980-5-5 980nm 5mW
from 6 711 ₽
Laser modules of the KLM-A980-5-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
PL-01 Heating plate
PL-01 Heating plate
Laboratory heating plate for heat treatment at temperature control and heating time. It can be equipped with an additional function for setting the heating speed. The heating platform is made of duralumin. The size of the heating surface: 284x220 mm. Heating temperature: 40-400 °C. It can be equipped with a tray for a sand bath.
Produced in: Tomsk
Furnace for heating in a protective environment CHO (3)-17/11
Furnace for heating in a protective environment CHO (3)-17/11
from 1 458 470 ₽
Designation of SNO(H)-17/11 Power, kW, no more than 8 Supply network voltage, V 380 Frequency, Hz 50
Produced in: Tula
Laboratory scales VLE-6202S
Laboratory scales VLE-6202S
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 6200g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * up to 500g ± 30; sv. 500g ± 50 The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg