Search

3961 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 552
    Names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3961 products
Pipette for liquid transfer (Pasteur) 2 ml. n/ster, pack.500pcs
Pipette for liquid transfer (Pasteur) 2 ml. n/ster, pack.500pcs
from 850 ₽
Pasteur's non-sterile pipettes are designed for dosing solutions during serological and bacteriological studies. Relief graduation is applied to each pipette. The constant diameter of the spout allows you to always get a drop of a given volume. A closed filling tank ensures safe operation
MiniMed
Suponevo
Produced in: Moscow, Bryansk region
Vacuum drying cabinet with automatic adjustment SNVS-25/3,5
Vacuum drying cabinet with automatic adjustment SNVS-25/3,5
from 662 607 ₽
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing of devices under low pressure conditions under various temperature conditions.
Produced in: Tula
Smart probe for connecting an external thermoelectric converter with built-in flash memory
Smart probe for connecting an external thermoelectric converter with built-in flash memory
from 11 454 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. A smart probe for connecting an external thermoelectric converter with a built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. The Android program is installed. Operating conditions of the SZVTP smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. The functionality of the smart probe SSVTP Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor. The Android program isinstalled. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Smart submersible reinforced probe L = 500 mm SZPGU.500P with built-in flash memory
Smart submersible reinforced probe L = 500 mm SZPGU.500P with built-in flash memory
from 11 940 ₽
Smart submersible reinforced probe L = 500 mm SZPGU.500P with built-in flash memory is designed to measure the temperature of various materials directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPGU.500P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPGU.500P smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Centering rings (stainless steel) with a metal-ceramic filter (stainless steel) and O-ring of circular cross-section
Centering rings (stainless steel) with a metal-ceramic filter (stainless steel) and O-ring of circular cross-section
The ISO-KF connection (DIN 28 403 and ISO 2861) allows quick installation and replacement of components in vacuum systems. The connection consists of two symmetrical ISO-KF flanges (1), a centering ring with an O-ring seal (2) and a quick-release clamp (3). High-vacuum ISO-KF connections can be mounted without using a tool by simply turning the nut of the quick-release clamp.
Produced in: Kazan
Universal frequency meter Ch3-97
Universal frequency meter Ch3-97
The device successfully combines simplicity of design, modern design, convenience, clarity of control and obtaining information about the measured physical quantity. Technical specifications Frequency and period of sinusoidal signals (inputs A, B) 0.001 Hz - 300 MHz Frequency and period of video pulse signals (inputs A, B) 0.001 Hz - 300 MHz Frequency of continuous sinusoidal oscillations (input C) (0.3 – 37.5) GHz Carrier frequency of a continuous radio pulse sequence (IM) signal (input C) Fn = (0.3-37.5) GHz, from 0.3 microseconds to 1ms, Fsl from 100 Hz to 1 MHz, from 2 to 103 Frequency ratio (inputs A, B) from 1 to 3x109 Pulse duration 5 ns - 1000 s The duration of the front, the decay of the pulses is 5 ns - 100 microseconds Time interval from -1000 to 1000 s Phase difference of two synchronous sinusoidal signals from minus 180° to 180° The measurement error of the phase difference of two synchronous sinusoidal signals is ± 2.3 ° at a signal amplitude of 1 V Setting range of trigger levels (inputs A, B) from - 2.0 to 2.0 V The error of setting the trigger levels (inputs A, B) ± 0.01 V Input signal level: •for sinusoidal signal (inputs A, B) (0.03 - 10.0) V •for video pulse signal (inputs A, B) (0.1 - 10.0) V •for a sinusoidal signal (input C) 0.1 - 5 MW Input resistance •Inputs A, B (50±2.5) ohms; (1±0.1) MOm/100 pF •Input With (50±2.5) ohms Nominal frequency value of the reference quartz oscillator 10 MHz Relative error in the frequency of the quartz oscillator, no more than ± 2x10-7 in 24 months Operating temperature range from minus 10 to 50 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 306x129.5x430.6 Weight, not more than 8.5 kg
Produced in: Moscow
Heating mantle LH-210 (1000-2000 ml)
Heating mantle LH-210 (1000-2000 ml)
The volume of the heated flask, ml 1000-2000 Maximum heating temperature, °C 600 Dimensions, mm 190x230x190 Power, W 900 Weight, kg 3.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Island shelf LAB-M StO 120.48.90
Island shelf LAB-M StO 120.48.90
Furniture for laboratory work. Island shelving Length, mm: 1200 Depth, mm: 480 Height, mm: 900 BASIC EQUIPMENT support racks – aluminum profile painted with powder paint (RAL 9016) with a "shagreen" texture upper shelf with a depth of 480mm – PVC with a thickness of 5mm in a frame of 2 aluminum profiles painted with powder paint (RAL 7011) with a "shagreen" texture, height adjustment is not provided lower shelf with a depth of 380mm – PVC with a thickness of 5mm in a frame of 2 aluminum profiles painted with powder paint (RAL 7011) with a "shagreen" texture, height adjustment is not provided
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Tubular furnace LF-20/250-12
Tubular furnace LF-20/250-12
Features: Horizontal operation mode; Ceramic working pipe, with two plugs; Heaters are placed along the entire length of the working chamber to ensure fast and uniform heating of samples to the required temperature; The microprocessor temperature controller allows you to maintain the temperature with an accuracy of ± 10 ° C; Conveniently located control panel with a bright LED display for displaying the current and set temperatures with a discreteness of ± 1 °C; Highly efficient thermal insulation to minimize heat loss, which contributes to rapid heating of the chamber and reduces energy consumption; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint; LED indicators of heater operation and protection operation; Easy to manage and control. Technical specifications: Set temperature range 100 ...1200°C Operating temperature range1 300 ...1200°C The error of reproducing the set temperature, no more ± 10°C Instability of temperature maintenance, no more ± 10°C Rated supply voltage 220 V Total power consumption 900 watts Overall dimensions (WxDxH) 350x270x400 mm Inner diameter of the pipe 20 mm Pipe length 250 mm Heated pipe length 220 mm The length of the isothermal zone with Δt=10 °C 80 mm Weight 19 kg
LOIP
Saint Petersburg
LI-500 Integrated Vacuum Trap
LI-500 Integrated Vacuum Trap
The integrated flanged trap LI-500 is installed inside the diffusion pump instead of the standard oil reflector, without increasing the overall dimensions of the diffusion pump. The LI-500 trap performs the function of an oil reflector, is installed instead of a standard oil reflector in pumps, has an additional number of cooled screens for capturing oil return flow vapors (more than that of the MU trap), covers the entire area of the input high-vacuum flange.
Produced in: Kazan
TAN-1 pH meter
TAN-1 pH meter
The TAN-1 potentiometric pH meter analyzer is a representative of a new generation of pH meters with a touch control panel. It is designed to measure pH and redox potential (Eh) with simultaneous temperature measurement.
Produced in: Tomsk