Search

36 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 10
    Applying
  • 16
    Names
  • 6
    Manufacturer
  • 4
    Made in
  • Additional
View:
36 products
Mold for the manufacture of tablets with KBr diameter of 13 mm
Mold for the manufacture of tablets with KBr diameter of 13 mm
It is intended for the preparation of samples in the form of compressed tablets consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). The mold is used in combination with the hydraulic press GP 200-13. - the mold is made of high-quality alloy hardened steel - to obtain better compressed tablets with KBr, the mold can be pumped out using a pre-vacuum pump. The customer can purchase the pump independently, or order it from the NPF “SIMEX”. Pumping out the mold is not necessary for most studies. - the kit includes a special dispenser for placing the optimal amount of the pressed mixture in the mold - to install the finished samples in the spectrometer, a holder of KBr tablets and D13mm substrate windows is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
IR Laser Module KLM-B808-x-5 808nm
IR Laser Module KLM-B808-x-5 808nm
Laser modules of the KLM-B808-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Focusing prefix MKF-Yu
Focusing prefix MKF-Yu
It allows recording transmission spectra of objects with sizes from 500 microns (precious stones, optical parts, semiconductor materials). It is also used in the study of samples compressed into small-diameter tablets with KBr (the method is convenient for spectral analysis of powdery substances - the prefix allows you to work with small amounts of the sample using a manual press for the manufacture of tablets). • The diameter of the focus spot is less than 3 mm • The design uses parabolic mirror optics • The set-top box is equipped with a set of replaceable diaphragm holders for samples of different sizes • Windows-substrates made of IR-transparent materials can be placed in the holder after pasty, liquid substances or extracts are applied to them, followed by drying of the layers • The slide table has the possibility of smooth movement in vertical and horizontal directions to achieve the maximum signal level
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Diamond thermal cell NPVO with temperature controller
Diamond thermal cell NPVO with temperature controller
The sample heating system is designed to expand the capabilities of standard set-top boxes NPVO-ZDO and NPVO-A. It consists of a heated replaceable frame with a diamond prism and a temperature controller unit. For most solid samples in the heated state, it is possible to obtain a much more pronounced NPV spectrum than in the cold state. This makes it possible to increase the sensitivity of the method several times. The properties of some substances and compounds change dramatically with an increase in temperature, chemical interaction processes between components, their decomposition, oxidation in air, etc. may occur. If changes in the chemical composition of a substance occur during heating, a set of spectra corresponding to the kinetics of the process can be obtained with the help of an NPVO prefix with a diamond thermocell and a temperature controller, which is essential expands the possibilities of the method in research. Technical characteristics of the NPVO set-top box with a thermocell and a controller Transmission in the operating range of the spectrum, % of the input signal at least 10 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 The depth of penetration of radiation into the sample, microns 5 – 15 Minimum dimensions of the solid sample, mm 0.5 × 0.5 Minimum volume of the liquid under study, ml 1 Minimum dimensions of the fiber sample: cross-section diameter/length, mm 0.3/1 The material of the crystal substrate is DIAMOND The diameter of the free zone of the crystal, mm not less than 2 x 3 The diameter of the focus spot, mm 1.5 Maximum temperature With 220o Adjustment accuracy, With 1o Time to reach the maximum temperature, min 10 Overall dimensions, mm 130×200×90 Weight, kg 1,2
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Infrared Laser 808 nm KLM-808-x
Infrared Laser 808 nm KLM-808-x
CDL lasers of the KLM-808-x series are optimal sources of continuous radiation for the construction of control and automation systems, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Infrared Fourier spectrometer "InfraLUM® FT-08"
Infrared Fourier spectrometer "InfraLUM® FT-08"
Technical specifications: Operating spectral range, cm-1 from 400 to 7800 Spectral resolution, cm-1, not more than 0.7 The limit of the absolute error of the wavenumber scale, cm-1 ± 0.05 Signal-to-noise ratio (RMS) for the wavenumber 2150 cm-1, determined in the range ± 50 cm-1 for a resolution of 4 cm-1 and an accumulation time of 60 s, at least 40,000 The limit of deviation of the 100% transmission line from the nominal values for the wave number 2150 cm-1, determined in the range ± 50 cm-1, % ± 0.2 The level of positive and negative pseudo-scattered light caused by the nonlinearity of the photodetector system, % ± 0.25 The time of setting the operating mode of the spectrometers, h, no more than 2 Continuous operation time of spectrometers, h, not less than 8 Power consumption, In × A, not more than 65 Overall dimensions, mm, not more than 580x550x340 Weight, kg, not more than 32 Average time to failure, h, not less than 2500 Average service life of the spectrometer, years, at least 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Manual mechanical press
Manual mechanical press
Designed for the preparation of samples in the form of compressed tablets with a diameter of 3.5 mm, consisting of the test substance in a mixture with microcrystalline potassium bromide (KBr). - the principle of operation of the device is based on creating the pressure necessary for pressing due to a mechanical lever system - the press is made of high-quality alloy hardened steel - for the manufacture of a tablet with a diameter of 3.5 mm, a minimum amount of the test substance and KBr is required - for the study of finished samples on a Fourier spectrometer, a vertical or horizontal microfocusing prefix is used
SIMEKS
Novosibirsk
Produced in: Novosibirsk
IR Laser Module KLM-A980-5-5 980nm 5mW
IR Laser Module KLM-A980-5-5 980nm 5mW
Laser modules of the KLM-A980-5-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Universal set-top box of NPVO and ZDO with a diamond element and a built-in mini-monitor
Universal set-top box of NPVO and ZDO with a diamond element and a built-in mini-monitor
It is designed for measurement by the method of disturbed total internal reflection with simultaneous visualization of a micro-object on an integrated and external monitor, as well as by the method of mirror-diffuse reflection with an angle of incidence of 45o at the upper location of the sample. The prefix in the mode of a single NIP is used to register absorption spectra: liquids of any degree of viscosity (solutions, suspensions, oils, etc.), including those with high chemical activity; solid objects of arbitrary shape, including samples with very high hardness (any polymers, fragments of paint coatings, etc.); powdery substances, including powders with very high hardness (drugs, pharmaceuticals, explosives, inorganic compounds); samples in the form of thin tapes; samples in the form of fibers. The maximum hardness and chemical resistance of the diamond significantly expand the possibilities of the method; there is no need for periodic replacement of the crystal. The set-top box allows you to register spectra without time–consuming sample preparation, and the presence of a visual inspection system of the studied surface with a high-quality video camera and a built-in high-definition mini-monitor increases efficiency when working with small samples - fragments of thin fibers, microparticles, etc. The built-in monitor has the functions of digital 10X zoom, inverting, etc. The image can be simultaneously displayed on the computer screen (using a USB interface) and then saved as a file. The removable flange provides a quick and convenient sample change and cleaning of the crystal surface. The design with a diamond element protruding above the base plane of the NPVO allows you to study samples with sufficiently large overall dimensions. The high quality and repeatability of the results is achieved due to the absence of the influence of the thickness of the substance layer on the shape of the spectrum and the intensity of the absorption bands. The sample retains its original physicochemical properties and, if necessary, can be further investigated by other methods. The universal attachment clamp is equipped with a precision lever mechanism for quickly lowering the tip and a micrometer screw that allows you to pre–set the optimal degree of pressure - this ensures quick sample change and repeatability of the results during measurements. For convenience when working with liquid and paste-like samples, as well as in the ZDO mode, it is possible to rotate the clamping console by 180o. The console is equipped with two replaceable tips – with a spherical working part and with a flat hinged head. The high hardness of the diamond allows the use of large clamping forces, which is the determining factor for obtaining high-quality spectra. A replacement table is used to register the specular and diffuse reflection spectra. The sample is located on the subject plane of the investigated surface downwards. The method is used to determine the spectral characteristics of optical parts, thin tapes on the surface, crystals, and other large solid objects of arbitrary shape and size.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Infrared Laser 980 nm KLM-980-x
Infrared Laser 980 nm KLM-980-x
CDL lasers of the KLM-980 series are optimal sources of continuous radiation for the construction of control and automation systems, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Reflection prefix PO-45 V
Reflection prefix PO-45 V
It is intended for express analysis of various types of solid opaque samples, including polymer films and fragments, paint coatings, finished dosage forms in the form of tablets, optical parts and semiconductor materials. • The sample is located on the subject plane of the investigated surface downwards, the angle of incidence of the central beam on the sample is 45 ° • The diameter of the focus spot is 3 mm • Allows you to explore objects of any shape and size • When using a mini-press, it allows you to examine samples in the form of a thin layer rolled out on a mirror plate made of alloy steel (radiation passes through the substance layer twice, reflecting from the mirror surface) • Not used: for the study of bulk and liquid substances
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Universal optical set-top box with zinc selenide element and integrated visualization system on an external monitor
Universal optical set-top box with zinc selenide element and integrated visualization system on an external monitor
It is intended for express analysis of various types of solid and liquid samples, including polymer particles, films and fibers, powdery substances, fragments of paint coatings, fuels and lubricants. The presence of an optical system for visual inspection of the surface under study with an increase of 75X ensures high efficiency when working with small samples – fragments of thin fibers, microparticles, etc. The universal clamp is equipped with a precision lever mechanism for quickly lowering the tip and a micrometer screw that allows you to pre–set the optimal degree of pressure - this ensures quick sample change and repeatability of the results during measurements. For convenience when working with liquid and paste-like samples, as well as in the ZDO mode, it is possible to rotate the clamping console by 180o. The console is equipped with two replaceable tips – with a spherical working part and with a flat hinged head. A replacement table is used to register the specular and diffuse reflection spectra. The sample is located on the subject plane of the investigated surface downwards, the angle of incidence of the central beam on the sample is 45 °. The method is used to determine the spectral characteristics of optical parts, crystals, thin films on the surface, as well as to register the absorption spectra of large solid objects. Transmission in the operating range of the spectrum, % of the input signal at least 30 The recommended number of scans when registering spectra is 25 Spectrum registration time at 25 scans (resolution 4 cm-1), sec 30 The depth of penetration of radiation into the sample, microns 5 – 15 Minimum area of a solid sample, mm 0.2 × 0.2 Minimum volume of the liquid under study, ml 1 Minimum dimensions of the fiber sample: cross-section diameter/length, mm 0.1/1 Substrate crystal material ZnSe CVD, Ge Focusing spot diameter, mm 1 The angle of incidence of radiation (central beam) on the sample in the ZDO mode 45o Magnification of the micro lens / total magnification of the visual channel 4X /75X Field of view of the optical system, mm 2 X 2.5 Digital video camera resolution 640 X 480 Overall dimensions, mm 150×150×260 Weight, kg 2.15 • Allows you to study objects of small size (from 200 microns - depending on the geometry, surface quality and physico-chemical properties of the material) • The attachment allows you to work without sample preparation, has a fixed adjustment of the pressure on the sample using a clamp equipped with color indicators • Thanks to the removable flange with the NPVO element, a quick and convenient sample change and cleaning of the crystal surface is provided • At a given optimal contact force, the method provides high quality and repeatability of results due to the absence of influence of the thickness of the substance layer on the shape of the spectrum and the intensity of the absorption bands • The sample retains its original physical and chemical properties and, if necessary, can be further investigated by other methods
SIMEKS
Novosibirsk
Produced in: Novosibirsk