Lumeks

Lumeks

39 products
View:
Telephone number:
Address:
Russia, Saint Petersburg, 1, letter B
Address:
Russia, Saint Petersburg, 1, letter B
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 9
    Applying
  • 11
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 16
    Additional
View:
37 products
Analyzer of sodium hypochlorite in water "AGH-3"
Analyzer of sodium hypochlorite in water "AGH-3"
1 supp.
Technical specifications: Output of results to digital display board, RS485, RS232; current loop 4-20 mA (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations is 20-200 g/l Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Relative humidity at + 25 °C 80 % Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +25 °C Ambient temperature from +5 to +35 °C Atmospheric pressure 87-107 kPa The warranty period of operation is 1 year Average service life of at least 3 years Dimensions - electronic block - optical unit no more than 300x400x150 mm no more than 120x90x90 mm Weight - electronic block - optical unit no more than 10 kg not more than 2 kg Power supply 187-242 V, 50 ± 1 Hz, from an autonomous source, 12V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of liquid samples "Lumas LIQUID"
Mass spectrometer for the analysis of liquid samples "Lumas LIQUID"
1 supp.
Technical specifications: ESI / APCI ionization method Time-of-Flight Mass Analyzer The maximum repetition frequency of the ejection pulses is 10 kHz Recording speed of spectra Up to 100 spectra per second Characteristics of a 12-bit ADC, 2 GHz The number of simultaneously defined components is unlimited Mass range 1-2000 m/z Resolution > 4000 Vacuum system of 2 Fornaps and 3 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Water hardness analyzer "AKMS-1"
Water hardness analyzer "AKMS-1"
1 supp.
Technical specifications: The range of detectable concentrations is 0.005-25.0 (5-25000) °F (mcgecv/L) The temperature of the analyzed flow is from + 5 to + 40 °C The pressure in the flow is 0.1-10 atm. Output of results Digital display of the device, portable display, RS485, RS232, current loop 4-20 mA (0-20) mA Display modes NORM, ALARM, LIMIT Version B4, P1, N1, according to GOST 12997-84 Category of climatic performance UHL4, according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80 % Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 300x400x150 mm Weight not more than 20 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "URP"
Mercury analyzer "RA-915M" with the prefix "URP"
1 supp.
Technical specifications: Continuous operation time 8 hours The dimensions of the analyzer are 470x220x110 mm The dimensions of the console are 340x240x120 mm Analyzer weight 7.5 kg The weight of the console is 5.5 kg Power supply 220 V Supply voltage of RA-915M: (220 ±22) V, 50 Hz URP supply voltage: (220±22) V, 50 Hz Power consumption of RA-915M: 35 VA URP power consumption: 220 VA Current frequency 50 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
Universal biochemical analyzer "FLUORAT®-02-ABLF-T"
1 supp.
Technical characteristics: Consumption of working reagents 1.0–2.0 ml – for standard filling cuvette K10 from 400 ml – for photometric techniques Filters for photometer mode, nm built-in interference filters 340, 405, 505 ,545, 575, 630 spectral half-width of 10 nm Filters for fluorimeter and chemiluminometer modes on request, in the spectral range of 270-850 nm Chemiluminescence channel sensitivity 10000 photons per second Optical density measurement range, E.O.P. 0-2.20 Photometric channel accuracy, %2 Memory of 100 measurement programs Temperature control of the measuring cell (for photometer and chemiluminometer modes) built-in thermostat on the Peltier element: 25, 30, 37 OC; accuracy ± 0.2 oC Volume of the flow cuvette, mkl 80 Pump type (only for photometer mode) peristaltic pump with programmable liquid supply volume Productivity, analyses/hour up to 100 (by the endpoint method) Information output liquid crystal display and personal computer Power supply, 220 ± 22 Dimensions, mm 430x350x160 Weight, kg 10
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
Mass spectrometer for the analysis of solid-phase samples "Lumas SOLID"
1 supp.
Technical specifications: Method of ionization Plasma pulsed glow discharge Discharge gas Argon, consumption less than 1 l/hour Time-of-flight Mass Analyzer with mesh-free ion mirror Resolution 4000 The number of simultaneously defined components is unlimited Mass range 1-1000 m/z Detection limits 1-100 ppb Layer-by-layer resolution Up to 5 nm Depth of analysis Up to 30 microns The time for one analysis of a solid sample is 30 minutes (with the option of a revolver system – 3-5 minutes) Vacuum system 1 Booster pump and 2 TMN (240 l/sec) Overall dimensions 1450×780×1550 mm
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Monochromators "LM-3" and "LM-4"
Monochromators "LM-3" and "LM-4"
1 supp.
Technical specifications: LM-3 operating range 220-650 nm LM-4 operating range 220-900 nm Diffraction grating (replica) 1200 strokes per millimeter Radius of curvature DR 125 mm The area of maximum energy concentration is 300-400 nm Inverse linear dispersion in the specified spectral range of 6.7 nm/mm Relative opening 1:3.3 The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slots is 5 mm The resolution of the monochromator with the specified slits in the ranges of 220-650 nm is not worse than 1.5 nm The resolution of the monochromator with the specified slits in the range of 650-900 nm is not worse than 2.5 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions no more than 205x125x150 mm Weight not more than 3 kg Supply voltage 90-120 / 187-242 V Power consumption not more than 12 W Current frequency 50/60 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury Monitor type RA-915AM for Natural Gas Analysis
Mercury Monitor type RA-915AM for Natural Gas Analysis
1 supp.
Technical specifications: Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 Volume flow rate of the analyzed gas at the monitor inlet, dm3/min, not less than 4 Monitor power supply from AC mains: voltage, V frequency, Hz 220 ± 22 50 ± 1 Power consumption, In × A, not more than 150 Overall dimensions (LXC), mm, no more 665x482x222 Weight, kg, not more than 25 Operating conditions: - ambient temperature, °C from 10 to 35 - relative humidity (at 25 °C), %, not more than 80 - atmospheric pressure, kPa from 84 to 106.7 - relative humidity of the analyzed gas (at 20 °C), %, not more than 99 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer "InfraLUM® FT-12"
Infrared analyzer "InfraLUM® FT-12"
1 supp.
Technical specifications: Measurement time, 80 seconds Standard sample volume in a cuvette, 50 ml Spectral range, cm-1 from 8700 to 13200 Spectral resolution, cm-1, no more than 10 The limit of the permissible value of the absolute error of the wave number scale, cm-1 ±0,5 Analyzer warm-up time, min, no more than 30 Continuous operation time of the analyzer, h, at least 8 Overall dimensions, mm, no more than 530x450x380 Weight, kg, not more than 32 Power supply of analyzers from the AC network: AC power supply voltage, V frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, not more than 110 Average time to failure, h, not less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury monitor type RA-915AM for air analysis
Mercury monitor type RA-915AM for air analysis
1 supp.
Technical specifications: Ambient temperature, °C from +10 to +35 Relative humidity (at +25 °C), % no more than 98 Atmospheric pressure, kPa from 84 to 106.7 Power supply 220  22 V, 50  1 Hz Power consumption, VA no more than 150 Overall dimensions (LWC), mm Monitor Multiplexer 665x482x222 665x482x222 Weight, kg Monitor Multiplexer (2-16 channels) 25 15 - 25 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
1 supp.
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg