Lumeks

Lumeks

20 products
View:
Telephone number:
Address:
Russia, Saint Petersburg, 1, letter B
Address:
Russia, Saint Petersburg, 1, letter B
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 14
    Applying
  • 11
    Names
  • 1
    Manufacturer
  • 1
    Made in
  • 16
    Additional
View:
37 products
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
Sample preparation system – microwave mineralizer "MINOTAUR®-2"
1 supp.
Technical specifications: Frequency of the generated magnetron radiation, MHz 2450 ±50 Number of simultaneously decomposed samples 1 The maximum volume of the processed sample, cm3 50 Maximum working pressure in the container, atm 9 Power consumption, V*A 600 The average absorbed power (W) in the reactor when heating 30 cm3 of distilled water at 100% output power level of the magnetron in the range of supply voltage from 187 to 242 V 150... 250 Average time to failure, h, not less than 2500 Average service life, years, at least 5 Overall dimensions, mm, no more than 500x450x150 Weight, kg, no more than 22
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Biochemical analyzer (photometer) "BIALAB-100"
Biochemical analyzer (photometer) "BIALAB-100"
1 supp.
Technical specifications: Methods of analysis optical density, endpoint, kinetics, fixed time, nonlinear, two-wave, turbidimetry Light source halogen lamp (12 V, 20 W) with a slow start system to increase the service life Built-in interference light filters 340, 405, 505, 546, 578, 630nm; spectral half-width 12 nm The optical density measurement range is 0-2.5 E.O.P. The measurement error of optical transmission is not more than 1 % Memory of 100 measurement programs Temperature control of the measuring cell built-in thermostat with Peltier element: 25, 30, 37 ° C; accuracy ± 0.2 ° C Sample incubation thermostat external, for 16 vials The volume of the flow cell is 32 µl Consumption of the working reagent from 250 µl Built-in matrix printer, printing on plain paper with a tape width of 56 mm Liquid crystal display: 4 lines of 20 characters each Productivity of up to 100 analyses/hour by the endpoint method Dimensions and weight no more than 355x355x185 mm; 8.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chromatographic columns for HPLC
Chromatographic columns for HPLC
1 supp.
Variants of execution: - silica gel with grafted octadecyl groups (C18, RP, ODS) - for the variant of reversed-phase HPLC (OF HPLC); - unmodified silica gel (SIL) – for normal-phase HPLC (NF HPLC).
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
1 supp.
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Thermoreactor laboratory "TERMION"
Thermoreactor laboratory "TERMION"
1 supp.
Technical specifications: Operating temperature range, °C 50 ... 175 The discreteness of the temperature setting, °C 0.1 Temperature setting accuracy, °C ± 2 Accuracy of temperature maintenance, °C ± 0.5 Time interval setting range from 1 min to 20 h 59 min Time setting discreteness, min 1 Power consumption, V * A, no more than 450 The size of the landing nest (diameter x depth), mm 17 x 72 Number of landing nests, pcs 29 Overall dimensions, mm, not more than 300 x 300 x 120 Weight, kg, not more than 8
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Atomic absorption spectrometer "MGA-1000"
Atomic absorption spectrometer "MGA-1000"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 900 Spectral resolution, nm, no more: - in the range from 190 to 600 nm inclusive - in the range over 600 to 900 nm inclusive 2 3 Limit of detection of manganese, pg, no more than 3 Nickel detection limit, pg, no more than 20 The time of setting the operating mode of the spectrometers, min, no more than 15 The time of continuous operation of the spectrometers, h, no less than 8 The spectrometers are powered by a three-phase alternating current network: - rated supply voltage, V - frequency, Hz 380 (50 ±1) Overall dimensions of the spectrometer, mm, no more than 800 x 475 x 310 Mass of the spectrometer, kg, no more than 50 Power consumed by spectrometers, kV * A, no more: - in standby modes and settings of analytical parameters - in atomization and purification modes 0.1 6 Average time to failure, h, not less than 4000
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mercury analyzer "RA-915Lab"
Laboratory mercury analyzer "RA-915Lab"
1 supp.
Technical specifications: Measuring range 0.5–500 ng Sample dispenser capacity 5000 mg / 2800 ml Analysis time 1-5 min Operating temperature range with software control 50-950 °C with software control The capacity of the autosampler is 45 samples Power supply 220 ± 22 V, 50 ± 1 Hz Dimensions (LxWxH), no more: with autosampler without autosampler 450x840x460 mm 450x490x460 mm Weight, no more: with autosampler without autosampler 57 kg 40 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-104T"
Capillary electrophoresis systems "KAPEL®-104T"
1 supp.
Technical specifications: The working wavelength of detection, nm 254 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 150 Overall dimensions (LXC), mm, no more 420x460x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "LUMACHROM®"
Liquid chromatograph "LUMACHROM®"
1 supp.
Technical specifications: Operating spectral range, nm from 190 to 360 Limits of permissible absolute error of wavelength setting, nm ± 5 Detection limit of anthracene (wavelength 252 nm), ng/cm3, no more than 1 The limit of the permissible value of the relative mean square deviation of the output signal (n =5), % of the retention time over the peak area of 1.5 2 Limits of the permissible value of the relative change in the output signal (peak area) for 4 hours of continuous operation, % ± 5 Overall dimensions (LxWxH), mm, no more: 270x420x190 Weight, kg, not more than 9.5 Power consumption, V· A, not more than 50
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid chromatograph "Lumachrom-M"
Liquid chromatograph "Lumachrom-M"
1 supp.
The liquid chromatograph "Lumachrom-M" provides maximum automation of the analysis. The device is controlled using specialized software, which in combination with the continuous eluent supply mode and the autosampler gives the maximum level of autonomy of operation. In addition, such a solution minimizes labor costs and the influence of the human factor. The unique design solutions of the chromatograph provide continuous pulsation-free flow of the mobile phase in both isocratic and gradient modes, as well as the ability to work with any column sizes. Thanks to the improved technical characteristics on the Lumachrom-M device, it is possible to implement a wider list of techniques and GOST compared to previous models.
Lumeks
Saint Petersburg
Produced in: Saint Petersburg