Liquid chromatograph "Lumachrom-M"
Liquid chromatograph "Lumachrom-M"
1 supp.
The liquid chromatograph "Lumachrom-M" provides maximum automation of the analysis. The device is controlled using specialized software, which in combination with the continuous eluent supply mode and the autosampler gives the maximum level of autonomy of operation. In addition, such a solution minimizes labor costs and the influence of the human factor. The unique design solutions of the chromatograph provide continuous pulsation-free flow of the mobile phase in both isocratic and gradient modes, as well as the ability to work with any column sizes. Thanks to the improved technical characteristics on the Lumachrom-M device, it is possible to implement a wider list of techniques and GOST compared to previous models.
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury content indicator "SR-1"
Mercury content indicator "SR-1"
1 supp.
Technical specifications: The minimum limit of operation is 3×10-4 mg/m3 (the average daily MPC of a residential premises in accordance with GN 2.1.6.1338-03 of May 21, 2003) The range of set thresholds is from 3×10-4 mg/m3 to 1×10-3 mg/m3 Measurement time, no more than 15 s Output signals ON, READY, DANGEROUS, FAULTY Electrical parameters of the output signal 0-24 V, 0.5 A Operating mode Monitoring Average full service life of 5 years Frequency of maintenance 1 time in 3 months RS-232 digital output Power supply 190-240 V, 50 Hz Power consumption, no more than 30 watts Overall dimensions, no more than 280x420x600 mm Weight, not more than 18 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Monochromator "MHD-2"
Monochromator "MHD-2"
1 supp.
Technical specifications: Range of operation 280-710 nm Diffraction grating (replica) 1250 strokes per millimeter The area of maximum energy concentration 350-450 nm The working order of the spectrum is the first The signal-to-noise ratio on the line is 632.8 nm when detuning from the center of the line by ± 3.3 nm is not worse than 3 * 106 times The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slits is 5 mm The resolution of the monochromator with these slits is not worse than 0.34 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions are not more than 335 x 153 x 240 mm Weight is not more than 8 kg Supply voltage 187-242 V Power consumption not more than 12 watts Current frequency 49-51 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
The FLUORAT®-411 alarm is heated, with a built-in sample preparation system
1 supp.
Technical specifications: The power consumption of the alarm is not more than 150 watts The output electrical signal goes directly from the cable entry (B6), according to the standard scheme (4-20ma and (or) RS 485) Sample temperature is not more than 200 degrees C Sample pressure is not more than 1.5 Atm The pressure of the spent sample is not more than 0.5 Atm Cooling water temperature 5-30 Deg C Dimensions of the alarm (mm) 1200*600*400 The boundaries of the spectral range of optical radiation used for analysis, nm 240 - 380 Analysis time, from 1 Power supply - alternating voltage (220 ± 10%) V, (50± 2.5) Hz operating mode settings, min no more than 30 Display range , mg/l 0.01-30 The limit of the basic error for the trigger threshold (%) 20 The set threshold for triggering the alarm 0.1 – 30.9 in increments of 0.1 mg/l the probability of trouble-free operation during 5000 hours is not less than 0.95 average recovery time, no more than 2 hours average service life, at least 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Aluminum analyzer in water "FLUORATE® AA-2"
Aluminum analyzer in water "FLUORATE® AA-2"
1 supp.
Technical specifications: The range of detectable concentrations is 0.04-2 mg/l The temperature of the analyzed flow is from + 5 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B4, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W Dimensions 600x600x250 mm Weight Not more than 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 10,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
Mercury analyzer "RA-915M" with the prefix "RP-91NG"
1 supp.
Technical characteristics: The set-top box is powered by AC (220 ± 22) V, 50 Hz Power consumption, VA, no more than 35 Continuous operation time, h 8 Overall dimensions: (LxWxH), mm, no more than 320x290x160 The weight of the console, kg, not more than 6.5 Air consumption, dm3/min 2 ... 5
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Capillary electrophoresis systems "KAPEL®-105M"
Capillary electrophoresis systems "KAPEL®-105M"
1 supp.
Technical specifications: The range of working detection wavelengths, nm from 190 to 380 Limits of permissible absolute error of setting the working wavelength, nm ± 5 The range of variation of the operating voltage on the capillary, kV from 1 to 25 The detection limit of benzoic acid (with positive polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, mcg/ cm3, not more than 0.8 The limit of detection of chloride ions (with a negative polarity of the high-voltage unit) at a signal-to-noise ratio of 3:1, micrograms / cm3, not more than 0.5 The limit of the permissible relative mean square deviation (SKO) of the output signal over the peak area, %5 The limit of the permissible relative mean square deviation (SKO) of the output signal for 8 hours of operation, % 6.5 Operating mode setting time, min, no more than 30 Power supply of systems from the AC network with voltage, V; frequency, Hz. 220 ±22 50 ±1 Power consumption consumed by the system, In ×A, no more: 220 Overall dimensions (LXC), mm, no more 420x570x360 Weight, kg, not more than 25
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Thermoreactor laboratory "TERMION"
Thermoreactor laboratory "TERMION"
1 supp.
Technical specifications: Operating temperature range, °C 50 ... 175 The discreteness of the temperature setting, °C 0.1 Temperature setting accuracy, °C ± 2 Accuracy of temperature maintenance, °C ± 0.5 Time interval setting range from 1 min to 20 h 59 min Time setting discreteness, min 1 Power consumption, V * A, no more than 450 The size of the landing nest (diameter x depth), mm 17 x 72 Number of landing nests, pcs 29 Overall dimensions, mm, not more than 300 x 300 x 120 Weight, kg, not more than 8
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Microparticle analyzer "SKAT-1"
Microparticle analyzer "SKAT-1"
1 supp.
Technical specifications: The time of one measurement is not more than 60 seconds Output of results to digital display board, RS485, RS232; current loop 4-20 mA, (0-20) mA The pressure in the flow is 0.1-10 atm. The range of detectable concentrations of suspended particles is 0.02-5 SCAT-1(VC); 0.1-100 SCAT-1(n) mg/l Execution B4, P1, N1 according to GOST 12997-84 Category of climatic execution UHL4 according to GOST 15150-69 Relative humidity at +25 ° C is not more than 80% The error of photometry per channel is not more than 1% The size of the analyzed microparticles is 0.5-50 microns Display modes NORM, ALARM, LIMIT The temperature of the analyzed flow is from +0.5 to +50 °C Ambient temperature from +0.5 to +50 °C Atmospheric pressure 84-106.7 kPa The warranty period of operation is 1 year Average service life of at least 5 years Dimensions 300x400x150 mm Weight not more than 20 kg Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption 100 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-5M"
Liquid analyzer "FLUORAT®-02-5M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, no more 0,005 Measurement range of the mass concentration of the control substance (phenol) in water, mg/dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ± 2 Warm-up time, min, no more than 30 Continuous operation time, h, at least 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, no more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, In × A, no more than 36 Time to failure, h, not less than 2500
Lumeks
Saint Petersburg