MAX-GF1(2)E-C Spectrometer
MAX-GF1(2)E-C Spectrometer
The X-ray fluorescence spectrometer SPECTROSCAN MAX-GF1(2)E-C combines two methods of detecting an analytical signal: diffraction on a crystal (wave dispersion - WDX) and energy dispersion (EDX) method, as well as sample delivery adapted for the analysis of large-size images. The collimation of the primary radiation of the X-ray tube and the special design of the sample presentation make it possible to analyze the sample over an area of 1 cm2 in 1 mm increments, and thus investigate the distribution of elements over an area. The spectrometer is designed to determine the contents of elements in the range from Ca to U in substances in solid, powdery, dissolved states, as well as deposited on the surface or deposited on filters. With the help of fixed energy dispersion channels, any one or two additional elements in the range from magnesium (Mg) to calcium (Ca) can be determined. With the help of this modification of the spectrometer, forensic and customs examinations, judicial and forensic medical examinations, as well as art-historical examinations are carried out.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Trace searcher Success AG-528.60N
Trace searcher Success AG-528.60N
from 225 630 ₽
The trace searching kit is designed to accurately determine the location and depth of underground utilities (power and signal cable lines, reinforced fiber-optic lines, pipelines made of electrically conductive materials), troubleshooting cable lines, and also allows you to conduct a survey of the area in the shortest possible time and with great reliability before excavation and to prevent damage to engineering communications. The kit includes a digital multifunctional tracking receiver with a large LCD display and audio output both to the built-in speaker and to the operator's headphones. The generator has increased power up to 180 watts and a range of up to 5 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
Power supply C35-80
Power supply C35-80
Operating Mode: Continuous Output stabilized current, A: 1-80 Output voltage, V: 0-35 Power supply: Three-phase 220/380 V 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 5.3 Overall dimensions (W x H x D), mm: 390 x 75 x 200
INZHEKT
Saratov
Produced in: Saratov
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 77 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Green DPSS Laser 515 nm KLM-515-x
Green DPSS Laser 515 nm KLM-515-x
DPSS lasers of the KLM-515/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Liquid thermostat VT-R-02
Liquid thermostat VT-R-02
The operating temperature range is +20...+100 °C. Two workplaces for placing prepared Raid bombs with pressure gauges. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. The volume of the bath is 30 liters Overall dimensions 335x280x800 mm The open part of the bath is 120x210 mm Bath depth 500 mm The size of the viewing window is 190x480 mm Weight 25 kg Power consumption 2.2 kW
Produced in: Tomsk
Installation for obtaining analytical quality water UPVA-5
Installation for obtaining analytical quality water UPVA-5
from 115 000 ₽
Capacity, l/h 5.0 (-10%) Purpose preparation of distilled water of type 2 according to GOST 52501-2005 "Water for laboratory analysis" FS.2.2.0019.18 "Water for injection" Heating elements Heating element 3.5 kW 220V (stainless steel) – 1 pc. The quality of the produced water GOST 52501-2005 "Water for laboratory analysis", FS.2.2.0019.18 "Water for injection" Type of current, frequency, voltage alternating single-phase, 50 Hz, 220 V Power consumption, kW 3,6 Overall dimensions (L×W×C), mm 424x417x454 Weight, kg 20,0
Livam
Belgorod
Produced in: Belgorod
3VVN1-3M(N) Water ring vacuum pump
3VVN1-3M(N) Water ring vacuum pump
The 3VVN1-3M(N) water ring vacuum pump with a capacity of 3.5 m3/min at an initial pressure of 0.04 MPa is designed for general industrial use, to create and maintain a vacuum in the operating pressure range from atmospheric to 10 kPa. The working fluid of the pump is water. The use of the 3VVN1-3M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working organs. The 3VVN1-3M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-3M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
ND-500 High-vacuum diffusion pump
ND-500 High-vacuum diffusion pump
The working condition of the ND-500 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-500 diffusion pump is a maximum of 5.5 liters, a minimum of 4 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change.The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of the heaters in the ND-500 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-500 diffusion pump up to 320°C, the temperature sensor should give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be carried out only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4 ° C to plus 25 ° C. The recommended cooling water consumption for the housing is 500 l/h, for the oil reflector it is 50 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break). The required speed of action of pre-vacuum pumps at a pressure of 26 Pa (0.2 mm Hg.st) in the outlet section of the ND-500 diffusion pump should be at least 42 l/s. To reduce the losses of the working fluid of the ND-500 diffusion pump at pressures (1·10-1- 1) Pa [(7,5·10-4- 7,5·10-3) mmHg] it is recommended to install an additional LP-500 flow-through water trap on the outlet flange.
Produced in: Kazan
Modular liquid cooling unit VCHV-20
Modular liquid cooling unit VCHV-20
from 329 585 ₽
Designation VCHV-20 Cooling capacity at Two.water= +15C, Tcond=+45C, Current.cp.=+30C, kW 20 Required pump capacity, m3/h 4,5 Pressure loss in the heat exchanger, kRa 60
Produced in: Tula