Ready buffer solution LEI 0701
Ready buffer solution LEI 0701
It is issued according to specifications 20.59.52-003-51284861 -2017 They are used as reference solutions for transmitting the pH scale of aqueous solutions during calibration and adjustment of pH meters of the 2nd-class accuracy and below, by direct measurement.
Produced in: Moscow
LEI-CL10-500 and LEI-CL10-250 Solutions for pH and ORP electrode cleaning, 500 ml,250 ml
LEI-CL10-500 and LEI-CL10-250 Solutions for pH and ORP electrode cleaning, 500 ml,250 ml
LEI-CL10 is a universal solution ("general purpose") for cleaning measuring electrodes of pH meters and ORP meters. It is used for cleaning glass membranes of pH electrodes. Over time, during pH measurements, the surface of the glass membrane of the electrode is covered with plaque and various deposits, often invisible to the naked eye. Because of this, the potential of the electrode changes by an amount greater than the permissible value – even when performing the correct calibration. As a result, the probability of errors in pH measurements increases, the response time and stability of the pH meter readings increases. The LEI-CL10 will allow you to clean the glass membrane and the diaphragm of the electrode, ensuring the cleanliness of the sensor element and preventing clogging of the diaphragm.
Produced in: Moscow
LEI-ST10 Solution for storage of pH and ORP electrodes
LEI-ST10 Solution for storage of pH and ORP electrodes
It is used for storing any pH electrode (filling protective caps). With proper storage of the pH electrode in solution, the glass membrane is well hydrated, which ensures proper operation and provides accurate readings, increases the durability of the electrode.
Produced in: Moscow
A set of electrodes for a DE distiller
A set of electrodes for a DE distiller
for water heating (in DE series aquadistillators)
Livam
Belgorod
Produced in: Belgorod
LEI-ST10 Solution for storage of pH and ORP electrodes
LEI-ST10 Solution for storage of pH and ORP electrodes
It is used for storing any pH electrode (filling protective caps). With proper storage of the pH electrode in solution, the glass membrane is well hydrated, which ensures proper operation and provides accurate readings, increases the durability of the electrode.
Produced in: Moscow
Ready buffer solution LEI 0401
Ready buffer solution LEI 0401
It is issued according to specifications 20.59.52-003-51284861 -2017 They are used as reference solutions for transmitting the pH scale of aqueous solutions during calibration and adjustment of pH meters of the 2nd-class accuracy and below, by direct measurement.
Produced in: Moscow
Device for preparation of graphite electrodes Crater-2
Device for preparation of graphite electrodes Crater-2
A machine for the preparation of graphite electrodes Crater-2. Two types of cutters can be installed simultaneously in the machine, for example, on a crater and a cone.
Produced in: Novosibirsk