Vacuum drying cabinet SNVS-90/5
Vacuum drying cabinet SNVS-90/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Vacuum firing furnace SNVS-400/7,0
Vacuum firing furnace SNVS-400/7,0
The vacuum furnace of the mine type SNVS-400/7.0 with top loading and pneumatic lid opening is designed for firing copper and other materials at temperatures up to 700 ° C and high vacuum up to -5 ·10-4 (6.67·10-5) mmHg (kPa). A technological platform with a ladder is provided for convenient operator access to the furnace. The mechanism of opening / closing the lid is provided by two pneumatic cylinders with pneumatic locks in the air line. A lifting platform is provided for loading coils into the furnace using an electric hoist. The design consists of a traverse, a stainless steel pipe and a perforated disc with a hook for suspension.
Produced in: Tula
Precision thermostatic bath LB-216
Precision thermostatic bath LB-216
Technical specifications: Temperature range, °C without external cooling (Current+10)...+100 with tap water cooling (Tvody+5)...+100 Accuracy of temperature maintenance, no more than, ° C ± 0.1 Power consumption, max., W 2200 Power supply 220±20 V, 50 Hz Working fluid water, water-glycerin mixture Dimensions of the working part of the bath /depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Bath volume, l 16 Weight, kg 13
LOIP
Saint Petersburg
Produced in: Saint Petersburg
CURRENT RELAY OF THE PARMA RH-2 SERIES
CURRENT RELAY OF THE PARMA RH-2 SERIES
The current relays of the PARMA Rh-2 series are designed to perform the functions of relay protection and automation of connections of 6 – 35 kV in networks with an isolated neutral. The current relays of the PARMA Rh-2 series combine the advantages of microprocessor protections and the simplicity of relay circuits on traditional electromechanical and electronic relays. The relay "PARMA Rh-2" is optimally suited: • for retrofit of cells to replace outdated relays with a switch of any type, including when using a deshunt circuit • as an alternative to modern microprocessor protections with excessive functionality • when creating and reconstructing RPA systems of power facilities in conditions of limited budget funds
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Aquadistillator electric AE- 2
Aquadistillator electric AE- 2
from 27 900 ₽
Capacity: 2.0 (-10%) l/h Heating elements Heating ELEMENT 1.5 kW 220V (stainless steel) – 1 pc. The quality of the produced water: FS.2.2.0019.18 "Water for LIVAM https://livam.pro/ Address: 308023, Belgorod, B. ave. Khmelnitsky, 134 a Phone: +74722568181 Mail for orders: sbyt@livam.ru Additional mail: livam@livam.ru #belgorod #distiller #equipped with ie #general laboratory ornoe #cleaning GOST R 58144- 2018 Type of current, frequency, voltage: alternating single-phase, 50 Hz, 220 V Power consumption: 1.5 kW Overall dimensions (L×W×C), mm 305×275×445 Weight: 4.8 kg Warranty period: 12 months from the date of sale Electrical conductivity of the produced water: 2-2.52 microns/cm The temperature of the produced water: from 70 to 85 ° C Source water consumption (at t of water 10 °C): 20 (±10%) l/h Source water pressure: 0.1-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 150×95×200 Version: Desktop with adjustable supports, Wall mounted (bracket is purchased separately) Coefficient of water purification from radionuclides, not less than 4000 Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
Aquadistillator electric DE-100
Aquadistillator electric DE-100
from 226 000 ₽
Purpose: obtaining distilled water of 3 types according to GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Capacity: 100.0 (-10%) l/h Heating elements: electrodes The quality of the produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current, frequency, voltage: alternating three-phase, 50 Hz, 380 V Power consumption: 60.0 kW Overall dimensions (L×W×C), mm: 810×630×1270 Weight: 81 kg Warranty period: 12 months from the date of sale Registration certificate for a medical device No. FSR 2008/03707 dated December 05 , 2008 Electrical conductivity of the produced water: 3-4.5 microns/cm Produced water temperature: 50 °C Source water flow rate (at 10 °C water temperature): 750 (+-10%) l/h Source water pressure: 0.1-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 400×220×500 Execution: outdoor Coefficient of water purification from radionuclides: at least 4000 Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
Chamber vacuum furnace SNVS-90/10-I2
Chamber vacuum furnace SNVS-90/10-I2
High-temperature furnaces are capable of heating materials up to 1700 degrees. The scope of their application covers the heat treatment of various materials in an inert medium or vacuum. TULA-TERM furnaces are used for heat treatment of plastics, ceramics, metals, alloys, lacquers and other materials. The equipment allows sintering, annealing, soldering, quenching, drying, burning and molding. In industry, our installations are most often used for quenching parts and sintering hard alloys.
Produced in: Tula
Vacuum drying cabinet SNVS-65/5
Vacuum drying cabinet SNVS-65/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Circulation thermostat LT-324a
Circulation thermostat LT-324a
Technical specifications: Temperature range: without external cooling, °C Current+10 ... +150 with tap water cooling °C Tvods+5 ...+150 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 8,0 pressure, 0.25 bar Bath volume, l 24 Working fluid water, water-glycerin mixtures, silicone oil Open part of the bath / depth, mm 360x296/200 Overall dimensions, mm 532x335x400 Weight, kg 15,5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Energy dispersive sulfur-in-oil analyzer ASE-2
Energy dispersive sulfur-in-oil analyzer ASE-2
The ASE-2 energy dispersive sulfur analyzer is designed to measure the mass fraction of sulfur in unleaded gasoline, diesel fuel, crude oil, kerosene, oil residues, lubricating oil bases, hydraulic oils, jet fuels and other distillate oil products. X-ray radiation from a low-power X-ray tube, converted by a primary radiation filter, excites fluorescence emission from the atoms of the sample being analyzed. The fluxes (primary X-rays scattered on the sample and secondary fluorescence) of radiation fall on a gas proportional counter, whereby the fluorescence radiation of sulfur atoms (SKa) is separated from the radiation with other energies by means of selective filters. The intensity of the fluorescence emission of sulfur atoms registered by the gas proportional counter is proportional to the mass fraction of sulfur in the analyzed sample.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
TA-Lab Voltammetric Analyzer
TA-Lab Voltammetric Analyzer
Automated device for measuring the content of toxic trace elements (As, Cd, Pb, Cu, Zn, Mn, Hg, Se, I, Ni, Co, Fe, Ag, Sb, Bi, Fe, Sn) in water, soil, food products by voltammetric methods with sensitivity at 1/10 of the permissible level (MPC) and below.
Produced in: Tomsk
AVD-50/5 Two-rotor vacuum unit
AVD-50/5 Two-rotor vacuum unit
The AVD-50/5 unit consists of a NVD-200 series-connected two-rotor vacuum pump and a 2NVR-5DM plate-rotor vacuum pump. 2NVR-5DM and NVD-200 pumps are installed on the lower and upper base of the frame and secured with bolts, nuts and washers. The pumps are connected to each other by means of a pipeline and a bellows assembly. By installing the rings during assembly of the unit, the size of the bellows assembly is set. The AVD-50/5 unit can operate continuously at an inlet pressure of no more than 133 Pa (1 mm Hg) or pumping out one or more sealed vessels with a total volume of 3.5 m3 from atmospheric to maximum residual pressure for 8 hours.
Produced in: Kazan