Equipment

2226 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 387
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 99
    Additional
    Loading...
View:
2226 products
Fermenter FA-01 from 1 to 3 liters
Fermenter FA-01 from 1 to 3 liters
1 supp.
Volume from 1.0 to 3.0 liters; case material – quartz glass, base and lid material – stainless steel AISI 304 (AISI 316); autoclaving sterilization method; direct-drive agitator, adjustable speed, special form for mixing viscous media, effective mechanical defoamer; sampling specifically for taking samples with high viscosity; original sensor sealing system, inputs are compatible with Mettler-Toledo sensors;  control of the fermentation process from the keyboard of a personal computer – control and maintenance of the basic parameters of fermentation, the introduction of an additional substrate (recharge) by various algorithms, in particular, by signals from the pO2 sensor, which can significantly reduce the consumption of substrates;  control and maintenance of pH, pO2, temperature;  easy assembly/disassembly, quick preparation for work in compliance with basic requirements and standards; fermenters can be combined into complexes of 4 pcs. Fermenters can be used in the pharmacological, microbiological industries, as well as in scientific research related to the cultivation of microorganisms.
Prointekh
Pushchino
Produced in: Moscow region, Pushchino
Vibroconvection dryer VKS-100/1,7
Vibroconvection dryer VKS-100/1,7
Vibroconvection dryer VKS-100/1,7 with a capacity of up to 100 kg / h for heating and drying bulk, granular and powdery materials in a vibrating boiling (fluidized) layer, in continuous and periodic mode. Vibroconvection dryers "VKS" are designed for heating and drying bulk, granular and powdery materials in a vibrating boiling (fluidized) layer, in a continuous and periodic mode. This is a type of fluidized bed in which mechanical vibration increases the productivity of the fluidization process, accelerates the process of heat and mass transfer, which ultimately leads to a reduction in the drying time of the product.
Produced in: Tula
CRYO-VT-12-1 Low-temperature liquid thermostat
CRYO-VT-12-1 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 360 W at +20 °C. Internal bath with a volume of 6 liters and a depth of 140 mm. The operating temperature range is -30...+200 °C. Overall dimensions 280x460x620 mm The open part of the bath is 110x80 mm Bath depth 140 mm Weight 39 kg Power consumption 3.0 kW.
Produced in: Tomsk
Generator of pure nitrogen and zero air GCHA-18D-60V
Generator of pure nitrogen and zero air GCHA-18D-60V
from 330 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol.(0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol. (7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 60 liters/hour (1000 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift work is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x425x510 mm Weight is not more than 25 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Polymerization furnace SNOL 11.47.4/2.5 P I2
Polymerization furnace SNOL 11.47.4/2.5 P I2
from 5 200 000 ₽
Designation SNOL 11.47.4/2.5 P I2 Temperature, oS 250 Camera power, kW 16 Mandrel length 1200...4600 Opening the lid electric drive
Produced in: Tula
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
RADIATION PEDESTRIAN MONITORS MPP‑AT920V, MPP‑AT920R (SRK‑AT2327)
Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software Mobility and the possibility to organize the control of passages in a short time High reliability and self-control Backup power supply
Produced in: Belarus, Minsk
Mobile laboratory NEURONET TECHNOAS 4 based on Gazelle Next
Mobile laboratory NEURONET TECHNOAS 4 based on Gazelle Next
Purpose of the NEURONET TECHNOAS 4 Laboratory • – Universal educational complex of modern educational technologies; • – Mobile remote and educational office for the working coherence of the subjects of activity. The use of the NEURONET TECHNOAS 4 laboratory • – Hardware and software complex based on multifunctional neuro-modular systems of electroencephalographs-recorders "Encephalan-EEGR-19/26"; • – Improving the productivity and profitability of the work of teams with physio-psychological diagnostics and correction, with machine neuro-training on biofeedback; • – Biophysical individual adjustment of the central nervous system; • – Conscious development of new reflexive meaningful states, rapid assimilation of new knowledge, skills, skills and actions; • – Reduction of dangerous influences of the human factor in responsible professions (aviation and others); • – Improving the effectiveness of educational programs for special education, retraining and advanced training. NEURONET TECHNOAS 4 Laboratory Support System • – MKZ safety control module; • – Mass switches in all compartments; • – Smart Home system, continuous monitoring of all life support systems with video recording; • – Audible alarm; • – Light alarm; • – An autonomous power source from batteries with a 12/220 V voltage converter; • – 12 V - 220 V sockets; • – Hardware and software complex of neuro-modular systems of electroencephalographs-recorders "Encephalan-EEGR-19/26"; • – Hardware and software complexes of modern educational technologies integrated with the Central Control Unit (central control unit).
Produced in: Kolomna, Moscow region
Sensor holder LTA-4DSH14
Sensor holder LTA-4DSH14
The stopper holder made of Teflon allows you to mount securely the temperature sensor of LTA electronic thermometers with a diameter of 4 mm in the 14/23-inch laboratory glassware.
Produced in: Tomsk
Nitrogen generator GA-200-N
Nitrogen generator GA-200-N
from 320 400 ₽
The GA-200-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-200 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-200, the GA-200-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.4 Volume fraction of oxygen is not more than, % vol. 0.6 Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati is at least 200 l/hour (3.33 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 1800 l/hour(30 l/min) Factory setting of the maximum pressure in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than, VA, 100 Overall dimensions (width x depth x height) are not more than, mm, 230x525x510; Weight is not more than 27 kg. Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure Hydrogen Generator GVCH-9M
Pure Hydrogen Generator GVCH-9M
from 158 400 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the performance, respectively, is 9 / hour (150 ml/min). Optionally equipped with a reactor for using hydrogen as a carrier gas. Technical specifications Purity of hydrogen in terms of dry gas is about 99.998% Concentration of water vapor at 20 OC and 1atm is no more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 9 l/h The time of setting the operating mode, with the output turned off is no more than 15 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 9 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.015 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 80 VA maximum (at startup) is no more than 100 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Combined mobile laboratory up to 35 kV (ETL-35K)
Combined mobile laboratory up to 35 kV (ETL-35K)
The combined laboratory up to 35 kV (ETL-35K) consists of: 1. Test facility • – Maximum rectified voltage up to 70 kV; • – Maximum AC voltage of the industrial frequency of 50 Hz to 100 kV. 2. Insulation parameters meter • – Transformation coefficient; • – No-load losses at low voltage; • – Short circuit resistance; • – Voltage and current; • – Power factor; • – Frequency of the measured voltage (current); • – Phase shift angle between voltage and current; • – Measurement of the active resistance of the windings. 3. Burning facility • – Maximum voltage up to 30 kV; • – Maximum current up to 80 A; • – Working hours are not limited; • – Switching of stages is carried out without breaking the arc at the time of switching; • – The ability to start working from any stage of burning (when working with low-voltage cables); • – Built-in afterburning. 4. High voltage pulse generator • – Output voltage 0...12 kV / 0...24 kV; • – The pulse energy at each stage is 3000 J; • – Built-in IDM for collaboration with the reflectometer. 5. Reflectometer – Supports 3 methods of determining the location of damage: • – By pulse reflectometry; • – By the method of oscillatory discharge; • – Pulse-arc method. 6. High-voltage cable defects detector • – Determining the location and depth of the cable at a depth of up to 10 m; • – Tracing at a distance of up to 10 km; • – Search for live electrical cables; • – Search for places where pipelines and cables intersect; • – Determining the places of damage to cable lines; • – Site surveys before excavation; • – Search for places of damage to the external insulation of the cable; • – GPS\GLONASS coordinates recording and mapping of found communications; • – Cable selection from the bundle; • – Search for the place of damage by acoustic method.
Produced in: Kolomna, Moscow region
Sandy bathhouse "PB" I2
Sandy bathhouse "PB" I2
from 54 251 ₽
The sand bath "PB" I2 with digital control and an increased heating area of 260x510 mm is designed for heat treatment of samples, evaporation and laboratory analysis. Optionally, the product can be equipped with a shutdown timer.
Produced in: Tula