PARMA

PARMA

19 products
View:
Telephone number:
Address:
Россия г. Санкт-Петербург Ленинский пр., дом 140
Адрес:
Россия г. Санкт-Петербург Ленинский пр., дом 140
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    All filters
    • 6
      Applying
    • 8
      Names
    • 1
      Manufacturer
    • 1
      Made in
    • 0
      Additional
      View:
      19 products
      ACCURATE TIME SIGNAL TRANSMISSION SYSTEM PARMA RV9.01
      ACCURATE TIME SIGNAL TRANSMISSION SYSTEM PARMA RV9.01
      Purpose and functions: · Receiving and transmitting the exact time to one or more subscribers · Synchronization of equipment operation at the exact time · Synchronization of subscribers by time within both one and several objects, i.e. creation of a hierarchy of subscriber systems tied to a single astronomical time at sufficiently large distances · Retransmission of accurate time signals to the shielded premises of objects (basements, mines, etc.) The PARMA RV9.01 system consists of a GPS receiver and a set (from 1 to 4) repeaters.
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      CAPACITOR PARMA KGI-10-100
      CAPACITOR PARMA KGI-10-100
      Appointment For use in measuring: · capacitance and tangent of the dielectric loss angle of high-voltage insulation (capacitors, inputs, transformers, insulators) · characteristics of partial discharges of liquid dielectrics in laboratory and field conditions, complete with an insulation parameter meter (for example, PARMA TENSOR-2)
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      FREQUENCY UNLOADING CABINET "PARMA SHE ACR"
      FREQUENCY UNLOADING CABINET "PARMA SHE ACR"
      The following options can be implemented on request: •additional time relays - allow you to time load control commands within one queue •output of ACR/CHAPV signals on one bus: the appearance of a signal - ACR, the disappearance of a signal - CHAPV •installation of a panel measuring device on the cabinet door •manufacture of cabinets of other dimensions, design and number of unloading queues •manufacture of outdoor cabinets
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
      MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
      Scope of application · measurement of electrical energy parameters in three-phase or single-phase current networks with their subsequent transmission to the upper level of the AIS · the device of the lower level in the AIS at the facilities of generation, conversion, transmission and distribution of electricity
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      DIGITAL EMERGENCY PROCESS RECORDER PARMA RP4.11
      DIGITAL EMERGENCY PROCESS RECORDER PARMA RP4.11
      UVI/PMU functionality · supports calculation and data transmission in on-line mode via the C37.118-2011 protocol · has 2 built-in Ethernet interfaces for connecting to the LAN of the installation object · saves data for later access via FTP – off-line mode · connection of up to 9 connections to one device with the possibility of distributed installation across the facility
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      VOLTAMMETER PARMA VAF-A(M)
      VOLTAMMETER PARMA VAF-A(M)
      Scope of application · operational maintenance of relay protection circuits and power circuits of electrical installations · phasing during adjustment of differential protection, connection of current and voltage transformers, electric motors · control of the correct phasing of the connection accounting circuits · removal of the volt-ampere characteristic and measurement of angles · monitoring of single- and three-phase circuits in power supply cabinets · measurement of secondary (up to 10 A) and primary (up to 3000 A) currents with one device
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      VOLTAMMETER PARMA VAF-A(C)
      VOLTAMMETER PARMA VAF-A(C)
      Scope of application · operational maintenance of relay protection circuits and power circuits of electrical installations · phasing during adjustment of differential protection, connection of current and voltage transformers, electric motors · control of the correct phasing of the connection accounting circuits · removal of the volt-ampere characteristic and measurement of angles · monitoring of single- and three-phase circuits in power supply cabinets
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      INSULATION PARAMETER METER PARMA TENSOR-2
      INSULATION PARAMETER METER PARMA TENSOR-2
      PARMA TENSOR-2 (AC bridge) is designed for automatic measurements of: · capacitance and tangent of the dielectric loss angle of high-voltage insulation of capacitors, inputs, transformers using an external high-voltage capacitor, both in laboratory and in the "field" conditions · effective values of the first harmonic of the current and voltage of the industrial frequency · the angle of phase shift between the signals supplied to the inputs of the device · network frequencies * Measurements can be carried out according to the "straight" and "inverse" (inverted) scheme. * Allocates the vector of the influence current, which makes it possible to dispense with the phase regulator of the test voltage source or devices for compensating the influence current.
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      RELAY PROTECTION UNITS FOR DIGITAL SUBSTATION OF THE IED-EP+ SERIES
      RELAY PROTECTION UNITS FOR DIGITAL SUBSTATION OF THE IED-EP+ SERIES
      A series of modern intelligent relay protection, automation and alarm units PARMA IED-EP+ is designed for use in networks with a voltage from 6 to 750 kV
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      DIGITAL EMERGENCY PROCESS RECORDER PARMA RP4.12
      DIGITAL EMERGENCY PROCESS RECORDER PARMA RP4.12
      USVI(PMU) functionality: · Supports computing and data transmission in on-line mode via the C37.118-2011 protocol · have two built-in Ethernet interfaces for connecting to the LAN of the installation object · save data for later access via FTP – off-line mode
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      MICROPROCESSOR DEVICE FOR AUTOMATIC FREQUENCY UNLOADING PARMA UACHR 12
      MICROPROCESSOR DEVICE FOR AUTOMATIC FREQUENCY UNLOADING PARMA UACHR 12
      PARMA UACHR 12 is designed to eliminate the shortage of active power in the network by automatically turning off consumers when frequency decreases, followed by automatic re-activation of previously disconnected consumers when frequency is restored, as well as to eliminate the shortage of reactive power in the network by disconnecting consumers when voltage decreases, followed by automatic re-activation of previously disconnected consumers when voltage is restored. PARMA UACHR 12 can perform the functions of dividing automation, be used at power plants and substations of power systems, as well as a device for local emergency automation of 0.4 kV networks as part of an automatic load control system. PARMA UACHR 12 is the first microprocessor-based frequency unloading device in Russia that has received a certificate of compliance with the requirements of the standard of the organization of JSC "SO UES" STO 59012820.29.020.003-2016 "Relay protection and automation. Automatic emergency management of power systems modes. Microprocessor devices for automatic frequency unloading. Norms and requirements" No. NC11.SO.RU.0417.0001 One PARMA UACHR 12 device can replace a typical ACR circuit made on microelectronic or electromechanical relays of the RSG-11 type; RF-1, RF-2 and URCH-ZM
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg
      PARMA KMT TEMPERATURE MONITORING COMPLEX
      PARMA KMT TEMPERATURE MONITORING COMPLEX
      The temperature monitoring complex "PARMA KMT" is designed for: • implementation of continuous wireless multi-channel monitoring of temperatures of controlled objects and the environment • issuing alarms when the threshold values (setpoints) of dangerous and emergency overheating are reached by temperature and dangerous overheating rate • detection of temperature differences on the same type of connections • display of the measured temperature and the control point • transmission of telemetry data to top-level devices in automated control systems via Modbus protocol for processing, archiving and analysis of measurements • archiving, displaying and analyzing data, identifying trends and developing defects at the PS, RES level based on the proposed parameterized SCADA The temperature monitoring complex "PARMA KMT" is installed in switchgears (RC) with a voltage from 0.4 to 35 kV in the places of movable contacts, busbars, transformer inputs, cables and their connections with busbars.
      PARMA
      Saint Petersburg
      Produced in: Saint Petersburg