Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter-radiometer ISS-15D "Bullfinch"
Dosimeter is a gamma-beta radiation radiometer for working in "dirty" conditions. Allows you to switch modes and take measurements in conditions of radioactive contamination. Measurement of the beta radiation flux density is carried out with automatic subtraction of the gamma radiation background. Purpose: measurement of the ambient dose equivalent of H*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; measurement of beta particle flux density; estimation of the counting rate with combined measurements of gamma and beta radiation.
Doza
Zelenograd
Produced in: Moscow
Contact thermometer TK-5.08 with the function of measuring relative humidity (explosion-proof)
Contact thermometer TK-5.08 with the function of measuring relative humidity (explosion-proof)
from 43 200 ₽
A unique, reliable device with a huge number of replaceable probes. The contact thermometer TK-5.08 is designed to solve problems of any complexity with the highest accuracy in the field of measuring the temperature of flammable liquids, bulk substances, air, explosive gas mixtures, solid surfaces and relative humidity of the air-gas environment at oil and gas and chemical industry enterprises. Shock-resistant and frost-resistant design allows you to operate the device in harsh climatic conditions.
Produced in: Moscow
Portable electrical Laboratory for testing and finding cable damage by acoustic and induction method Athlete KAI-2.502 (IDM)
Portable electrical Laboratory for testing and finding cable damage by acoustic and induction method Athlete KAI-2.502 (IDM)
Appointment Athlete KAI-2.502 (IDM) • Search for a live cable. • Detection of the location of the passage of hidden communications. • Preliminary detection of the distance to the place of damage. • Search for places of cable damage in an acoustic way. • Search for places of cable damage by electromagnetic means. • Cable insulation testing. • The "Friend-Foe" mode.
Produced in: Kolomna, Moscow region
MAESTRO-αMS gas chromatograph by Interlab
MAESTRO-αMS gas chromatograph by Interlab
We offer expert laboratories of physicochemical methods of analysis a gas chromatograph with a quadrupole mass spectrometric detector «MAESTRO-αMS». Quadrupole GC-MS «MAESTRO-αMS» is in demand for targeted research (screening) and non-targeted search. In targeted studies, it is necessary to detect given target compounds in samples of various nature and origin at the level of residual amounts, for example, several picograms of the target compound in the injected 1 μl of liquid sample. Most often, targeted research is carried out in the following areas of laboratory screening: ecology, food safety, clinical monitoring, narcology, doping control, production control of various raw materials. In targeted studies, it is often required not only to confirm the presence of a compound in a sample, but also to determine the level of its content quantitatively, since both the list of target compounds and the permissible level of their presence in the sample are specified by regulatory documents. Quantitative analysis requires standards for the substances you are looking for. When conducting a non-target search, as a rule, it is required to analyze a sample of unknown composition, in other words, to find as many compounds as possible in the sample and identify (identify) each of them. Since the identification of a detected compound is carried out by comparing its experimental mass spectrum with the spectrum of a pure substance obtained under standard conditions, this task requires reference libraries of mass spectra of pure substances, as well as tools for working with mass spectra, for example: algorithms for cleaning experimental mass spectra from background and spectral noise (mass spectrum deconvolution algorithms), library search and comparison algorithms. An off-target search is called a qualitative analysis, since the researcher is primarily interested in the list of detected substances, and not in the quantitative assessment of their content in the sample. When creating MAESTRO-αMS, we took into account our own many years of experience in operating imported analogues. We have made the device inexpensive. We have made the device compact: The modern design of the device made it possible to make the MAESTRO-αMS really compact, so that the device occupies the smallest possible area on the laboratory table. The layout of the device allows you to remove the ion source on the front flange for cleaning and replacing the cathodes, if necessary. We have reduced the cost of operation: When developing the MAESTRO-αMS, we sought to increase the resistance of the device to sample matrices and use a minimum of consumable materials in order to eliminate downtime for maintenance and replacement. As a result, we have created an extremely stable ion source and a perpetual photomultiplier detector. We have created special software: Even at the first acquaintance with the software, it becomes obvious that being in the window of each button and each parameter to be changed is expedient and logical. Our software product was created for the convenience of the operator, so we implemented the necessary and eliminated the unnecessary. We used the principle of one active window, in which the operator moves sequentially step by step, performing hardware settings, setting the data collection method, subsequent processing algorithms, templates for presenting the results. MAESTRO-αMS offers a wide range of scanning modes, built-in algorithms for working with mass spectral data, convenient unloading of initial data arrays for their processing in specialized software packages, graphics export for presentations and scientific publications. You can use several libraries of mass spectra at the same time, or create your own for your typical tasks. Finally, we provide a 5-day training course for professionals who want to understand the theoretical foundations of the method and their implementation in the hardware of modern quadrupole GC/MS. The volume and depth of presentation of the material from the developers of the device is intended to lay the foundation for the effective use of «MAESTRO-αMS» in the future. Some technical characteristics of MAESTRO-αMS: • Instrumental detection limit (SIM, OFN @272 m/z ) < 10 fg; • Scan modes: scan for selected ions, full scan in a given mass range, combined scan mode; • The number of simultaneously connected libraries of mass spectra is at least 10.
Produced in: Moscow
EVRAZCOMB – TSC
EVRAZCOMB – TSC
Purpose: Temperature measurement, sampling of molten metal Scope of application: Oxygen converters Measuring range: from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
High-sensitivity HICMOS digital Camera
High-sensitivity HICMOS digital Camera
The highly sensitive HICMOS digital camera manufactured by Abisens LLC is used to register weak light signals, including bioluminescence, in real time, with a photon counting function and visualization of the signal accumulation process in real time (you do not need to wait for the end of the exposure time to see the light signal accumulated by this moment). It is used as a component of high-tech laboratory equipment for scientific research, including installation in the fluorescence and bioluminescence imaging System in LumoTrace® biological samples manufactured by Abisens LLC.
Abisens
Sirius
Produced in: Krasnodar region
Tripod "workplace" for single and stripped 0.2 ml tubes, 96 seats (plexiglass)
Tripod "workplace" for single and stripped 0.2 ml tubes, 96 seats (plexiglass)
Material of manufacture: Plexiglass Product Color: Transparent Tripod legs: rubber (to prevent sliding) For test tubes: 0.2 ml.
VIS MED
Berdsk
Produced in: Bryansk, Novosibirsk region