Search

10 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 7
    Applying
  • Names
  • 4
    Manufacturer
  • 5
    Made in
  • 1
    Additional
View:
10 products
EVRASAMP ES Sampling of the required configuration
EVRASAMP ES Sampling of the required configuration
Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Sampler type: with a ladder - oval shape, circle Operating temperature range (depending on the type of sampler): from 1460°C to 2020°C Selection time: from 3 to 5 seconds Tube length: from 100 to 1500 mm (other length is possible on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
Produced in: Lipetsk
EVRASAMP ESC Sampling with low carbon content
EVRASAMP ESC Sampling with low carbon content
Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Type of sampler: Ceramic sampler with an elongated leg Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
Produced in: Lipetsk
IPA-01 Wearable Sampler
IPA-01 Wearable Sampler
from 20 000 ₽
Determination of the integral concentration of radioactive aerosols in the personnel breathing area (exposure time 8 hours) by radon (thoron) daughter products and long-lived radionuclides in accordance with the requirements of NRB-99 and OSPORB-99. Automatic stabilization of the air sampling rate. (It is possible to supply additional consumables to IPA - 01)
Produced in: Moscow
EVRASAMP ESU Sampling of the required configuration
EVRASAMP ESU Sampling of the required configuration
Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Induction furnaces, steel ladles, metal finishing plants, filling ladles, etc. Sampler type: Sand shape – sample thickness 6 mm, 8 mm, 10 mm, 12 mm Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
Produced in: Lipetsk
EVRAZCOMB – 2 in 1
EVRAZCOMB – 2 in 1
Purpose: Temperature measurement and sampling of molten steel. Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1400 to 1800 °C - metal temperature Accuracy: 0 + 3°C at 1554°C The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Cardboard Type of NSH: B, S, R
Produced in: Lipetsk
EVRAZCOMB – TSC
EVRAZCOMB – TSC
Purpose: Temperature measurement, sampling of molten metal Scope of application: Oxygen converters Measuring range: from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
GAS SAMPLER
GAS SAMPLER
They are used for sampling natural and liquefied gas. In the company "Meta-chrome" you can buy the following gas samplers: PGO-50M; PGO-400; BDP 12-2-9,8 (aluminum, subcompact); PU. The PGO-50 M, PGO-400 and PU models are used to take samples of liquefied hydrocarbon gases that are affected by the overpressure of stationary tanks and or their own vapors. Sampling is carried out according to GOST 14921-78. The BTP 12-2-9.8 device is used for sampling, storing and transporting samples of gases that are under pressure. The device is made of aluminum and is designed for a small liter. Sampling is carried out according to GOST 31370-2008. INDICATOR BDP7 BDP7 BDP12 BDP12 BDP16 PGO-400 PGO-50M Volume, l. 0,7 1 2 4 10 0,4 0,05 Outer diameter, mm 70 70 120 120 160 50 35 Length, mm 360 480 368 593 800 400 325 Working pressure, MPa 9.8 5.0 9.0 The number of refills up to the operating pressure, times at least 5000 Case material AMg6M 12X18
Produced in: Yoshkar-Ola, Mari El
EVRAZCOMB – TSO
EVRAZCOMB – TSO
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters Measurement range: from 1 to 2000 ppm O2 - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the level of oxygen activity) The shape of the selected metal mold: Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42mm, thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other lengths are available on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk
EVRAZCOMB – 3 in 1
EVRAZCOMB – 3 in 1
Purpose: Measurement of temperature, oxygen activity and sampling of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, casting buckets Measuring range: from 1 to 2000 ppm O - metal oxidation from 1400 to 1800 °C - metal temperature from 0.010 to 0.200% - carbon content Accuracy: 0 + 3 °C at 1554 °C; (from 5 to 10) mV (depending on the oxygen activity level) The shape of the selected metal shape: Circle: thickness 12 mm Oval: thickness 12 mm Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium Measurement time: 8 sec Tube Length: from 100 to 2500 mm (other length is possible on request) Slag Cap: Steel, Aluminum, Copper, cardboard Type of NSH: B, S, R
Produced in: Lipetsk