Equipment

2285 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 394
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 91
    Additional
    Loading...
View:
2285 products
DOSIMETER‑RADIOMETER ISS‑AT6130S
DOSIMETER‑RADIOMETER ISS‑AT6130S
A small-sized device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. The case is made of impact-resistant ABS plastic Convenient menu Search mode
Produced in: Belarus, Minsk
UNIVERSAL EXHAUST HOOD DEMONSTRATION MODELS: LK-900, LK-1200, LK-1500
UNIVERSAL EXHAUST HOOD DEMONSTRATION MODELS: LK-900, LK-1200, LK-1500
from 114 060 ₽
1. LK-1500 SMS-D (case - chipboard) Width - 1500 Ceramics - 91 230 ₽ GRANTEC- 99 320 ₽ 2. LK-1500 SMS-D (case - polypropylene) Width - 1500 Ceramics - 102 100 ₽ GRANTEC- 115 980 ₽ 3. LK-1500 SMS-D (case - steel) Width - 1500 Ceramics - 113 920 ₽ GRANTEC- 131 500 ₽
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
NV-1100 SHV-LVZH Fume cupboard with HIL storage compartment and countertop made of granite
NV-1100 SHV-LVZH Fume cupboard with HIL storage compartment and countertop made of granite
from 100 014 ₽
The Kors NV-1100 SHV-LVZH laboratory fume cupboard is a specialized single—frame cabinet with a granite countertop with a width of 1090 mm and a built-in iron compartment for storing highly inflammable liquids (HIL). External dimensions of the cabinet (W×D×H): 1090×700×1960 mm. Reliable fume cupboard for storage of HIL and combustible substances The lower compartment of the cabinet is a built—in metal cabinet designed for the safe storage of highly inflammable liquids. The double walls of the cabinet with an insulating air space provide fire resistance. Compartment capacity: 57 liters. External dimensions: 1090×460×460 mm. It is made of welded steel with a thickness of 1 mm. The width of the insulating air layer is 38 mm. It is coated with a durable epoxy polyester powder paint that protects against moisture and corrosion (nevertheless, acids and alkalis cannot be stored in it). The lower shelf with sides 50 mm high protects the laboratory from accidental spillage of liquids. The middle shelf can be hung at different heights in 76 mm increments. There are two ventilation openings with flame arresters in the sides of the cabinet. The compartment doors open at 180 degrees. They are equipped with a lock that can be sealed. Working area of the fume cupboard Working surface material: porcelain tile. It is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. Limited resistance to hydrofluoric acid. This is one of the most popular types of countertops for laboratory furniture. The working area is closed by a single lifting frame with a counterweight. It has two exhaust zones: the hood of the exhaust box and the level of the countertop. Diameter of the flange for connection to the ventilation system: 150 mm. The height of the raised glass above the cabinet: 510 mm, that is, when the glass is raised, the height of the cabinet will be 2470 mm. The working area is illuminated by a fluorescent lamp (included in the package). The switch is located on the right side of the cabinet, next to the sockets. The fume cupboard is equipped with two sockets, one of them with grounding. Sockets have the IP20 degree of protection, maximum load: 1.5 kW. The base of the cabinet is an all-welded metal frame in powder coating. The side laminated panels (chipboard 16 mm thick) are edged on the facade with a durable PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The cabinet legs are adjustable in height within two centimeters, allowing you to place the cabinet even on a rather uneven floor. Advantages of the Korsa NV-1100 SHV-LVZH cabinet A specialized solution for laboratories that work a lot with highly inflammable and combustible substances. It is suitable for small-sized rooms. Heating plates or baths can be placed on the porcelain stoneware surface. It is resistant to high temperatures. It is convenient to work standing up: the height of the work surface from the floor is 85 cm (this is the height of an ordinary kitchen corner). Application of the Korsa NV-1100 SHV-LVZH cabinet Exhaust laboratory cabinets are used when working with toxic and harmful volatile materials, with clean materials, with dissolution or decomposition under temperature treatment, during sample analysis and many others. In this cabinet, highly inflammable liquids (HIL) and combustible substances can be stored in a special metal compartment. In the event of a fire in the laboratory, this compartment can maintain a safe temperature inside for some time. Fume cupboards of the NV series are used in laboratories of the widest profile: at food and light industry enterprises, in higher educational and scientific institutions, in chemistry classrooms at school, in quality control centers, medical organizations.
NV LAB
Moscow
Produced in: Moscow, Moscow region
Dosimeter-radiometer ISS-05 "Terra" Bluetooth
Dosimeter-radiometer ISS-05 "Terra" Bluetooth
Modification of the ISS-05 "TERRA" dosimeter-radiometer with a Bluetooth radio channel module. A small-sized device for monitoring radiation conditions with the ability to save and transfer measurement results to a PC. Purpose: measurement of the ambient dose equivalent of N*(10) gamma radiation; measurement of ambient dose equivalent of H*(10) gamma radiation; measurement of beta particle flux density;
Doza
Zelenograd
Produced in: Moscow
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1002 (IDM)
Search and diagnostic complex for finding cable damage by acoustic and induction method Athlete KAI-2.1002 (IDM)
Purpose Athlete KAI-2.1002 (IDM) • Determination of the type of damage and the distance to the place of damage to the cable. • Tracing a cable line up to 10 km. • Determination of cable depth up to 6 m. • Troubleshooting of cable lines by induction method. • Troubleshooting of cable lines by acoustic method. • Cable insulation testing.
Produced in: Kolomna, Moscow region
Fume Umbrella-Cupboard SHZV-NRZH.120
Fume Umbrella-Cupboard SHZV-NRZH.120
Overall dimensions 1200x800x1905 mm Internal dimensions 1150x775x950 mm The diameter of the exhaust pipe is 200 mm Weight 108 kg
Produced in: Tomsk
Oscilloscope S1-176
Oscilloscope S1-176
It is intended for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0-50 MHz, as well as for monitoring the parameters of two- and three-pole devices using a component tester. Technical specifications: Number of channels 2 Bandwidth 0 - 50 MHz Deviation coefficients of 2 mV/div - 20 V/div (step1-2-5) Installation error ± 3%, ± 4% with a 1:10 divider Rise time of PH <= 7 nsec Input impedance is 1 mOhm/25 pF, with a divider of 1:10 - 10 mOhm/23 pF Harsh operating conditions (-10°C to +40°C) Bandwidth 0 - 50 MHz Two channels Indication of deviation and sweep coefficients on LED matrices Tenfold stretching of the sweep Calibrator 0.6 V, 1 kHz (± 1%) X-Y mode Built-in Component Tester Screen 80x100 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
EVRAZCARB For measuring the carbon content in steel
EVRAZCARB For measuring the carbon content in steel
Purpose: Measurement of the percentage of carbon in steel Scope of application: Furnaces, buckets, cupola furnace Measuring range: from 0.01 to 2.00% carbon Accuracy: 0.01 %
Produced in: Lipetsk
VIS-T-D4 Holder
VIS-T-D4 Holder
It is the holder with spring clip for working viscometers of types VPJ 1, VPJ 2, VPJ 4, residence permit, Cannon Fenske Routine, Cannon FenskeOpaque, Ubbelohde, BS/IP/RF.
Produced in: Tomsk
VD-90NP Eddy current flaw detector in the basic configuration
VD-90NP Eddy current flaw detector in the basic configuration
from 295 000 ₽
The principle of operation of the device: The principle of operation of the flaw detector is based on the excitation of eddy currents in the controlled product and the subsequent release of a signal at the output of the converter, the amplitude and phase of which are determined by the secondary field of eddy currents. Design features and advantages of the VD-90NP flaw detector. The device has a small-sized case, which ensures its lightness, ergonomics and allows you to mount it on your belt or on your arm. The measurement is performed using a remote converter connected by a flexible cable. There are several types of converters for eddy current flaw detection of products made of different materials and different geometries. The large and bright display displays the selected operating modes and measurement results in text and graphic form. The VD-90NP is also characterized by: high sensitivity (it detects cracks starting from 0.1 mm in size); dust–and-moisture-proof housing, which makes it applicable for work in the field; large operating frequency range; maximum working clearance up to 10mm; Bluetooth connection; the ability to control products with high surface roughness, up to Rz320 class; light and sound indication of defect detection; wide operating temperature range from –30°C to +50°C; autonomous low-voltage power supply; long continuous operation time from one set of batteries; compliance with the standard GOST R ISO 15549-2009 (ISO 15549:2008). The use of a microprocessor-based hardware and software platform provide it with the following operational characteristics: automatic adjustment when measuring conditions change, including compensating the influence of the gap; built-in calibration modes; saving the measurement results in the internal memory of the device; a large number of stored programs: sets of parameters and measurement modes, both preset and saved by the user so as to repeatedly monitor the same type of products; The Bluetooth 2.0 wireless communication module allows the device to be used in conjunction with an external laptop or mobile device for remote control, transmission of measurement results for further storage, printing, documentation and analysis. Scope of application: The eddy current method is suitable for non-destructive testing and detection of microcracks in products and parts made of any metals and alloys of complex shape, with high surface roughness, through non-conductive coatings, as well as for checking welded joints. The flaw detector can be used to control parts and assemblies of aviation equipment. The VD-90NP eddy current flaw detector is used for quality control and preventive examination of: - components and parts of rolling stock at railway transport enterprises: wheel sets, auto coupler housings, side frames, spring beams, labyrinth rings, pulleys; - pipes, profiles, rods at rolling mills at the output control, and at the input control of consumers of products; - products made of aluminum and titanium alloys with multilayer coatings at enterprises of the aviation and aerospace industry; - cables, beams, critical components of equipment (cranes, lifts) in construction; - main pipelines in order to detect stress corrosion. A wide range of operating temperatures, dust and moisture protection (IP54 degree of protection), autonomous low-voltage power supply, a long time of continuous operation of the device allows it to be used in the field at low temperatures and under precipitation (rain, snow). Basic kit: • 1 electronic unit for the VD-90NP eddy current flaw detector; • 1 Ia5.125.052 (Type-2) eddy current converter; • 1 converter cable; • 1 charger with batteries; • 1 hand strap; • 1 Ia8.896.104 sample with artificial defects; • 1 Ia8.896.035 coating sample; • 1 storage and carrying case; • 1 documentation set.
Produced in: Moscow