Aquadistillator electric ADE-50
Aquadistillator electric ADE-50
from 127 000 ₽
Purpose: obtaining distilled water of 3 types according to GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Capacity: 50.0 (-10%) l/h Heating elements: Heating element 3.5 kW 220V (9 pcs.) Quality of produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current, frequency, voltage: alternating three-phase, 50 Hz, 380 V (±10%) Power consumption: 31.5 kW Overall dimensions (L×W×C), mm: 700x500x800 Weight: 40 kg Warranty period: 14 months from the date of sale Registration certificate for a medical device No. FSR 2008/03708 of December 05 , 2008 Electrical conductivity of the produced water: 3-4.5 microns/cm The temperature of the produced water: from 70 to 85 ° C Source water flow rate (at 10 °C water temperature): 380 (±10%) l/h Source water pressure: 0.1-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 310x220x395 Execution: Outdoor Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
Vacuum drying cabinet with automatic control SNVS-210/5
Vacuum drying cabinet with automatic control SNVS-210/5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with an appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing devices under low pressure conditions under various temperature conditions.
Produced in: Tula
Chamber electric resistance furnace CHO-8.16.5/12.5
Chamber electric resistance furnace CHO-8.16.5/12.5
from 550 000 ₽
Designation: SNO-8.16.5/12.5 Temperature: 1200 Open.doors: electromechanical Camera size (w.G.V.): 800x1600x500 Regulation zones: 2
Produced in: Tula
Circulation thermostat LT-416b
Circulation thermostat LT-416b
The LOIP LT-416b modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 16 The working fluid is water, silicone oil. Open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Weight, kg 12.9
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M"
Mercury analyzer "RA-915M"
1 supp.
Technical specifications: Measuring range of mass concentration of mercury vapors in the air, ng/m3 from 20 to 20000 Limits of permissible basic relative error, d0, % ± 20 The limit of permissible relative standard deviation of the analyzer output signal, %5 The limit of the permissible value of the mean square deviation (SKO) of the zero signal, ng/m3 2 Drift of the zero signal of the analyzers in 5 minutes, ng/m3, no more than 2 The limit of permissible change of analyzer readings for 8 hours in fractions of d0 0.5 Time to establish the readings, s, no more than 20 Time of analyzer output to the mode, min, no more than 20 Volumetric flow rate of the analyzed air at the analyzer inlet, dm3/min, not less than 10 Volumetric air flow at the outlet of the gas analyzer system with the inlet blocked, dm3/min, not more than 0.3 Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 The limit of permissible additional error due to changes in ambient temperature within the operating range for every 10 ° C, in fractions of d0 0.5 The analyzers are powered by a built-in AC battery voltage (220 ±22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, not more than 7 Reliability indicators average time to failure, h, at least the full average life from the built-in AC battery voltage (220 ± 22) In the frequency (50 ±1) Hz Power consumption, In × A, not more than 35 Continuous operation time of the analyzers from the built-in battery, h, at least 8 Overall dimensions of the analyzers, mm, no more than 470x110x220 Mass of analyzers, kg, no more than 7 Reliability indicators average time to failure, hours, at least full average service life, years, at least 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Hydrogen Generators GVCH-6
Hydrogen Generators GVCH-6
from 126 000 ₽
The GVCH-6 hydrogen generators are designed to power flame ionization detectors. They are equipped with a four-stage gas purification system. The hydrogen capacity is 6 liters/hour (100 ml/min). They have smooth adjustment and digital indication of the output pressure. Technical specifications The brand of produced hydrogen "A" according to GOST 3022-80 Purity of hydrogen in terms of dry gas is about 99.995% The concentration of water vapor at 20 ° C and 1.0 ati is not more than 20 ppm Total hydrogen capacity reduced to normal conditions is 6 l/h The range of the specified output pressure of hydrogen is from 1.5 to 6.0 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode is no more than 30 min Volume of bidistilled water to be filled is 1 l Consumption of bidistilled water is no more thann 0.01 l/hour Consumption of bidistilled water is 1.6 g/l of hydrogen Average power consumption in stationary mode is no more than 100 VA Maximum power consumption (at startup) is no more than 150 VA Overall dimensions of the generator, (width x depth x height) are not more than 180x450x435 mm The mass of the generator is not more than 11 kg Working conditions: ambient temperature, °C from +10 to +35 Power supply from single-phase mains: AC voltage, 220±10% and frequency, Hz 50 ± 1
Produced in: Moscow
Muffle furnace MIMP-6P (desktop version)
Muffle furnace MIMP-6P (desktop version)
The furnace can be used as a universal laboratory muffle furnace in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications The furnace operates at ambient temperatures from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. The designation of the furnace when ordering: muffle furnace MIMP-75P, where 75 indicates the volume of the furnace working chamber in liters. Power consumption – 3500 W Dimensions of the working chamber WxDxH- 205x200x185 mm Dimensions WxDxH- 460x580x550 mm Weight – 54* kg (* - with control unit)
MIUS
Tula
Produced in: Tula
XFP CWDM Transceiver
XFP CWDM Transceiver
XFP (10-Gigabit Small Form Factor Pluggable) is a protocol—independent hot-swappable optical transceiver, usually operating at 850nm, 1310nm or 1550nm wavelengths or wavelengths from the CWDM band at a speed of 10 gigabits per second in SONET/SDH, Fiber Channel, Gigabit Ethernet, 10 Gigabit Ethernet and other applications, including WDM channels.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
AUTOMATED LABORATORY INSTALLATION
AUTOMATED LABORATORY INSTALLATION
The unit is designed for testing isobutane dehydrogenation catalysts in the fluidized bed by activity and selectivity, as well as conducting life tests in automatic continuous mode without limiting the number of test cycles. technical specifications Reactor made of titanium or nickel-free steel 800mm long with an internal diameter of 30 ± 1mm with a removable coaxial pocket for three control thermocouples; The furnace is a hinged, four-zone furnace with an operating temperature range from 50 to 800 ° C with a length of 900 mm with an automatic accelerated cooling system necessary for drying the catalyst before testing at a temperature of 300-400 ° C.; A generator of four gas flows (isobutane, nitrogen, air, hydrogen), based on electronic regulators of the mass flow of gas with an error of no more than 0.5%; A gas flow switch that implements the necessary sequence of supply and mixing of gases entering the reactor, pressure monitoring in the reactor necessary to assess the degree of filter clogging, reverse purging of filters to clean them, automatic loading and unloading of the catalyst in nitrogen without the presence of air, as well as automatic filling of the heated reactor with nitrogen during an emergency power outage and hydrogen supply for regeneration; Power supply 230V 50Hz; Overall dimensions 800x800x2000; The installation is placed in a ventilated cabinet with a glass lockable door; Gas flow heater with operating temperature range from 20 to 500C installed if necessary before entering the reactor; Determination of qualitative and quantitative characteristics of the gas mixture at the reactor outlet using a gas chromatograph with an automatic analysis results processing system, with an assessment of activity and selectivity.
Serological bath SB-SL-01M
Serological bath SB-SL-01M
from 182 000 ₽
The serological bath SB-SL-01M replaced the BSL bath. The sauna is designed to perform laboratory tasks that require maintaining a constant temperature. The bath is perfect for serological studies, allowing to install 4 Florinsky tripods of 100 test tubes. The bath is made of high-alloy stainless medical steel. The bath body has double thermal insulation with a low coefficient of thermal conductivity. The heating element is located at the bottom of the bath over the entire working area of the bath, which allows for uniform heating of the working fluid and stable maintenance of the set temperature regardless of fluctuations in ambient temperature and the frequency of opening and closing of the lid. The warranty for the bath is 5 years. Microprocessor temperature controller with controller and touch control keys. The heating element is protected from overheating (for example, in case of a decrease in the water level). The control unit is equipped with indicators for turning on the heater and emergency operation of the protective circuit.
Produced in: Saint Petersburg
Trace Searcher Success AG-501
Trace Searcher Success AG-501
from 137 940 ₽
A trace searching kit for finding underground communications (cable lines, metal pipelines, and other communications made of conductive materials) with a digital tracerouting receiver. The kit is equipped with a compact stand-alone generator with a display and a built-in induction antenna. The output power of the generator is up to 20 watts and the operating range is up to 3 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region