MEASURING AND COMPUTING COMPLEX "VULKAN-2005M" AND "VULKAN-2005M1 VACUUM TESTER"
MEASURING AND COMPUTING COMPLEX "VULKAN-2005M" AND "VULKAN-2005M1 VACUUM TESTER"
The measuring and computing complex "Vulkan-2005M" and "Vulkan-2005M1 Vacuum Tester" are designed to measure the pressure of vapors and gases in a given volume when determining the thermal stability of substances in the isothermal mode, carried out according to the certified methodology of the customer, developed specifically for each substance. The CPI is included in the State Register of Measuring Instruments. technical specifications The measurement range of barometric pressure is from 86.6 kPa to 106.7 kPa. The absolute pressure measurement range should be from 5 kPa to (Ratm. +250) kPa, where Ratm. – atmospheric pressure. The limit of permissible error of pressure measurement does not exceed the values of: – barometric - ± 0.5 kPa. – overpressure - ± 2.0 kPa. – total (barometric + excessive) - ± 2.5 kPa. The temperature range in the reaction volumes of primary converters is from +50 to +280 °With the use of reusable fluoroplastic gaskets, from 280 to 400℃ with the use of disposable aluminum gaskets. Instability of maintaining the set temperature in thermostats for 10 minutes no more than ± 0.1 ° C. The discreteness of setting the temperature of temperature control is 0.1 ° C. The error of setting the temperature of temperature control does not exceed ± 2 ° C. The total volume of the glass is 20 ml. Minimum vacuum: 5 kPa. The IVC consists of up to 4 thermostats with primary converters, 8 in each thermostat. The time interval between measurement cycles in automatic mode is 1 second. The emergency protection is triggered when the values, pressure or temperature set in the control program are exceeded. The hardware overheat protection of the thermostat is triggered when the maximum operating temperature of the complex is exceeded. The IVC is powered from an AC mains voltage of 220V with an acceptable deviation from minus 15% to +10% frequency (50 + 1) Hz with a coefficient of nonlinear distortion of no more than 5%. The output time of the thermostats to the mode from the moment they are turned on does not exceed 3.5 hours. The power consumption of the CPI, no more than 4 kW. Overall dimensions of one thermostat, (width × depth × height), no more than -450×460×600mm. The weight of one thermostat, no more than 32 kg. The continuous operation time of the CPI is at least 72 hours.
Produced in: Yoshkar-Ola, Mari El
Tracing generator AG-105
Tracing generator AG-105
from 100 740 ₽
The automatic tracing pulse generator AG-105 is designed to create propagating signals (vibrations) in the routes of hidden communications with the active method of tracerouting. The device creates an alternating sinusoidal current in the studied communication (constantly or in short-term parcels) necessary to determine its location. The features of the AG-105 generator Extremely high power output and battery life, for a compact battery pack ("Type C" × 8) and such small overall dimensions. Universal power supply allows you to reach an output power of over 20 watts. With autonomous power supply, the "life cycle" depends on the quality of the "type C" batteries used. For example, with an initial output power of 7 watts in continuous generation mode, the "life cycle" is ≈ 5 hours, and with an initial output power of 15 watts in intermittent modulation mode, the "life cycle" is ≈ 25 hours (using standard new "fresh" batteries, for example, "Energizer C"). When using "ultra-high-capacity" batteries (for example, "Duracell ULTRA" or "COSMOS"), the battery life can be increased by 20-30%. When connecting an external "12V" battery (for example, a car), the operating time is determined by the capacity of this battery. When connecting an external mains power supply "15 V", the operating time is not limited. The dimensions of the portable device in the case are 216x180x105 mm, and the weight does not exceed 2 kg. These features are provided by the use of an ultra-efficient unique modification of the circuit technology for building CLASS D power amplifiers. The pulse output amplifier reaches an efficiency of 85%, which is especially important for "energy-consuming" devices with autonomous power supply.
Produced in: Kolomna, Moscow region
2VVN1-25 water ring vacuum pump
2VVN1-25 water ring vacuum pump
The use of a 2VVN1-25(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-25(H) pump. The 2VVN1-25(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
2NVBM-630(R)/12000 Booster High Vacuum pump
2NVBM-630(R)/12000 Booster High Vacuum pump
The 2NVBM-630(R)/12000 booster pump consists of housings, a steam pipe, a trap and a heater. The required effective speed of action of the pre-vacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-630(R)/12000 booster pump is not less than 100 l/s. The maximum residual pressure of the pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6x10-4Pa (5x10-6mm Hg). The pressure of the cooling water at the pump inlet 2NVBM-630(P)/12000 should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2) The discharge from the pump should be free with a jet break. Cooling water consumption 1200 l/h. The total amount of working fluid for the 2NVBM-630(R)/12000 pump is 65 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1x10-2 to 1x10-1 mmHg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
Water bath for six persons LOIP LB-160
Water bath for six persons LOIP LB-160
Temperature range, °C (Current +5) ... +105 Accuracy of temperature maintenance, °C ± 1 Temperature setting error, °C ± 1 Power consumption from AC 220 V, no more, 1600 W Number of jobs, pcs 6 The diameter of the workplace, mm 110 Volume of working fluid, l 13 Useful part of the bath / depth, mm 428x300 / 62 Overall dimensions, mm 530x330x140 Weight of the device without liquid is not more than kg 7
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Nitrogen generator GA-400
Nitrogen generator GA-400
from 408 000 ₽
Nitrogen generators are designed to create an inert atmosphere, fill low-pressure tanks and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. The warranty period of operation of the generator is 12 months from the date of sale by the manufacturer. Technical specifications Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.5 Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity is at least 400 l/h (6.66 l/min) The time of setting the operating mode for single-shift operation is no more than, min, 30 Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3000 l/h (50 l/min) Power consumption is not more than 100 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm; Weight is not more than 30 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Vacuum drying cabinet with manual control SNVS-40/5
Vacuum drying cabinet with manual control SNVS-40/5
from 440 732 ₽
The SNVS-40/5 vacuum drying cabinet with a volume of 40 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 500 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
The field of fast and thermal neutrons in a collimated beam Fast neutron field in “open” geometry using a screening cone according to ISO 8529-2 Drum source magazine with polyethylene and concrete protection at a depth of 1 meter Software control of the movement of sources and positioning of the mobile platform An alarm and blocking systems, radiation monitoring Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
MARK® 509 hydrogen meter
MARK® 509 hydrogen meter
Measurement of the concentration of dissolved hydrogen (CRV), including "ultra-low", and the temperature of aqueous media. Continuous monitoring of parameters of water-chemical regimes at thermal and nuclear power facilities. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic temperature and barocompensation. Long-lasting, highly stable sensor | The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance | from the sampling point Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-603
MARK-603
Measurement of electrical conductivity (UEP, UEP25), equivalent salinity and temperature of water and aqueous solutions, including deionized and "ultrapure". Operational control of water-chemical regimes at thermal power facilities. Control of electrical conductivity of water for laboratory analysis of 1, 2 degrees of purity according to GOST 52501-2005. 24-month warranty for deliveries across the Russian Federation Double automatic temperature compensation (ATC) Allows high-precision measurements of the conductivity of "ultrapure" water Selection of the coefficient of thermal compensation at the request of the User Stainless steel flow-immersion sensor Does not require calibration. The sensor design ensures the stability of the permanent cell Electronic notebook Ability to record up to 500 measurement groups in User-named folders Self-diagnosis Ion exchange column with sample current switch IP65 The compact sealed device is reliably protected from dust and moisture USB port, software included Graphic indicator with backlight Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 87 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg