GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
Designed to control the pressure and flow rate of non-aggressive gases in the lines of chromatographic and other analytical equipment. The measurement of gas flow is based on the conversion of the mass flow rate of gas into an electrical signal by the calorimetric method. The measured gas flow and pressure are displayed on a digital indicator. The device has an external RS485 interface, operating under the MODBUS RTU protocol. technical specifications: - gas flow measurement range – from 1 to 750 ml/min; - pressure measurement range from 0 to 0.4 MPa; - gas flow measurement error – no more than ± 2% in the measurement range of 100 art. ml / min; no more than 3% in the measurement range of 100 ... 750 art. ml / min; - measurement error suppression – no more than ± 0.25 %; - measured gases: Air, Nitrogen, Hydrogen, Helium, Argon, Methane; - the presence of a function for monitoring the volume of pumped gas for a given period of time; - the presence of a function for monitoring changes in gas pressure for a given period of time;- the device is powered from an external power source + 15V (an adapter for operation from a 220V 50Hz network is included in the delivery package).
Produced in: Yoshkar-Ola, Mari El
Laboratory electronic thermometer LTA-E
Laboratory electronic thermometer LTA-E
It can be used as an accurate universal thermometer for contact temperature measurement of non-aggressive liquid, bulk and gaseous media. It can be connected to a computer for calibration and transmission of measurement results. • Range of temperature measurements -50...+200 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Universal measuring complex UIM-MD
Universal measuring complex UIM-MD
Stationary complex for monitoring various parameters of the radiation situation, depending on the type of connected detection units: - continuous monitoring of gamma and neutron radiation in rooms and workplaces; - assessment of alpha and beta and gamma contamination of surfaces of objects, personnel clothing and small items. Purpose: measurement: ambient dose equivalent power of photon and neutron radiation; alpha and beta radiation flux densities; surface activity of Pu-239 and Sr-90+Y-90 radionuclides; alarm about exceeding the set thresholds.
Doza
Zelenograd
Produced in: Moscow
VD-90NP Eddy current flaw detector in the basic configuration
VD-90NP Eddy current flaw detector in the basic configuration
from 295 000 ₽
The principle of operation of the device: The principle of operation of the flaw detector is based on the excitation of eddy currents in the controlled product and the subsequent release of a signal at the output of the converter, the amplitude and phase of which are determined by the secondary field of eddy currents. Design features and advantages of the VD-90NP flaw detector. The device has a small-sized case, which ensures its lightness, ergonomics and allows you to mount it on your belt or on your arm. The measurement is performed using a remote converter connected by a flexible cable. There are several types of converters for eddy current flaw detection of products made of different materials and different geometries. The large and bright display displays the selected operating modes and measurement results in text and graphic form. The VD-90NP is also characterized by: high sensitivity (it detects cracks starting from 0.1 mm in size); dust–and-moisture-proof housing, which makes it applicable for work in the field; large operating frequency range; maximum working clearance up to 10mm; Bluetooth connection; the ability to control products with high surface roughness, up to Rz320 class; light and sound indication of defect detection; wide operating temperature range from –30°C to +50°C; autonomous low-voltage power supply; long continuous operation time from one set of batteries; compliance with the standard GOST R ISO 15549-2009 (ISO 15549:2008). The use of a microprocessor-based hardware and software platform provide it with the following operational characteristics: automatic adjustment when measuring conditions change, including compensating the influence of the gap; built-in calibration modes; saving the measurement results in the internal memory of the device; a large number of stored programs: sets of parameters and measurement modes, both preset and saved by the user so as to repeatedly monitor the same type of products; The Bluetooth 2.0 wireless communication module allows the device to be used in conjunction with an external laptop or mobile device for remote control, transmission of measurement results for further storage, printing, documentation and analysis. Scope of application: The eddy current method is suitable for non-destructive testing and detection of microcracks in products and parts made of any metals and alloys of complex shape, with high surface roughness, through non-conductive coatings, as well as for checking welded joints. The flaw detector can be used to control parts and assemblies of aviation equipment. The VD-90NP eddy current flaw detector is used for quality control and preventive examination of: - components and parts of rolling stock at railway transport enterprises: wheel sets, auto coupler housings, side frames, spring beams, labyrinth rings, pulleys; - pipes, profiles, rods at rolling mills at the output control, and at the input control of consumers of products; - products made of aluminum and titanium alloys with multilayer coatings at enterprises of the aviation and aerospace industry; - cables, beams, critical components of equipment (cranes, lifts) in construction; - main pipelines in order to detect stress corrosion. A wide range of operating temperatures, dust and moisture protection (IP54 degree of protection), autonomous low-voltage power supply, a long time of continuous operation of the device allows it to be used in the field at low temperatures and under precipitation (rain, snow). Basic kit: • 1 electronic unit for the VD-90NP eddy current flaw detector; • 1 Ia5.125.052 (Type-2) eddy current converter; • 1 converter cable; • 1 charger with batteries; • 1 hand strap; • 1 Ia8.896.104 sample with artificial defects; • 1 Ia8.896.035 coating sample; • 1 storage and carrying case; • 1 documentation set.
Produced in: Moscow
Picoammeter A2-4
Picoammeter A2-4
System meter of small currents. The device allows to make measurements in almost the entire range of currents. The picoammeter is characterized by high performance, which is important for its use as part of automated measuring systems. Technical specifications: Current measuring range 1x10-14 - 1x10-2 A Error for the range 10-11, 10-10 ±[0.5+0.025(lk/lx-1)]% for the range 10-9, 10-8 ±[0.25+0.01(lk/lx-1)]% for the range 10-7, 10-6,10-5, 10-4,10-3, 10-2 ±[0,1+0,01( lk/lx-1)]% The time of setting the readings is 2x10-2 - 2x10-5 s Supply voltage 230 (±20) V, frequency 50 (± 0.5) Hz Power consumption 10 VA Overall dimensions (HxWxD) 105x284x366 mm Weight 3.5 kg Operating temperature 5 - 40 °C Humidity 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
General purpose exhaust cabinet LAB-PRO SHV 90.74.230 KG
General purpose exhaust cabinet LAB-PRO SHV 90.74.230 KG
BASIC EQUIPMENT Working box guide racks – aluminum profile painted with powder paint (RAL 7035/RAL 5023)in the right rack there are a light switch and 2 splash-proof sockets with a 3.2kW cover (IP54) the front anti–spill side is acid-resistant polished stainless steel AISI 304 side panels – tempered glass 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-780mm, do not change the dimensions of the cabinet when lifting the upper fixed screen – metal painted with powder paint (RAL 5023) with the texture of shagreen leather back and top panels – polypropylene LED lamp dust- and moisture-proof (10W IP65) switching box with automatic emergency power off 16A flange d=250mm (the distance from the back panel to the center of the flange is 170mm) easily removable exhaust visors 3 exhaust levels (lower, side and front) counterweights are placed in the front pylon racks and are easily serviced The frame base is a collapsible frame made of a rectangular metal profile painted with powder paint (RAL 7035) with the texture of shagreen leather service panel is a metal box painted with powder paint (RAL 5023) with the texture of shagreen leather: adjustable supports.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Installations for verification of gamma radiation dosimeters portable UPGDS-3D
Installations for verification of gamma radiation dosimeters portable UPGDS-3D
Appointment: for transmitting units: the kerma power in the air of gamma radiation (MC); the ambient dose equivalent of gamma radiation (MAED); the power of the directional equivalent of the dose of gamma radiation (MNED); the exposure dose of gamma radiation (MED); the absorbed dose in the air of gamma radiation (MPD); it is used for verification and calibration of dosimetric measuring instruments in the gamma radiation field of the Cs-137 source under normal climatic conditions; it can be used as part of mobile laboratories, portable verification posts at enterprises.
Doza
Zelenograd
Produced in: Moscow