Search

14 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 11
    Applying
  • 12
    Names
  • 4
    Manufacturer
  • 5
    Made in
  • Additional
View:
14 products
X-ray Radiation Dosimeter clinical DRK-1M-CT
X-ray Radiation Dosimeter clinical DRK-1M-CT
Purpose: measurement of the product of the air kerma by length, followed by the calculation of the CTDI tomographic dose index (using the CTDI phantom) for the following calculation of the effective dose received by the patient; monitoring the stability of medical X-ray machines during their operation; calculation of the dose index of a computer tomograph (MPCT) according to GOST R IEC 61223-2-6-2001.
Doza
Zelenograd
Produced in: Moscow
KRP-UR Mobile radiographic cabinet (Fluorograph)
KRP-UR Mobile radiographic cabinet (Fluorograph)
The cabinet is designed for operation at outdoor air temperatures from minus 40°C to plus 40°C.
Produced in: Podolsk
Gamma and X-ray radiation dosimeter DKG-09D "Chizh"
Gamma and X-ray radiation dosimeter DKG-09D "Chizh"
Purpose: measurement of the ambient dose equivalent of gamma and continuous X-ray (photon) radiation N *(10); measurement of the ambient dose equivalent of gamma and continuous X-ray (photon) radiation N *(10).
Doza
Zelenograd
Produced in: Moscow
DRK-1M X-ray Dosimeter
DRK-1M X-ray Dosimeter
Purpose determination of the effective dose of patients in radiation diagnostics; control of stability of parameters of X-ray machines
Doza
Zelenograd
Produced in: Moscow
X-ray Radiation Dosimeters Clinical DRC
X-ray Radiation Dosimeters Clinical DRC
X–ray radiation dosimeters clinical DRC, depending on the modification, are designed for: measuring the product of the kerma (absorbed dose) in the air by the cross-sectional area of the X-ray beam (hereinafter referred to as the product of the kerma in the air by the area) when using the DRC-1, DRC-1E, DRC-1M Outline, DRC-1M dosimeters with the DRC measuring console-1M-E03, DRC-1M-E04, DRC-1M-E05, DRC-1M-E06; measurements of the product of the kerma power (absorbed dose) in the air per area (hereinafter referred to as the product of the kerma power in the air per area) using the DRK–1E and DRK-1M dosimeters equipped with the DRK-1M-E06 measuring console; measurements of the product of the kerma (absorbed dose) in the air along the length (hereinafter referred to as the product of the kerma in the air along the length) using DRK-1M-CT dosimeters; measurements of kerma (absorbed dose) in the air; measurements of the kerma power (absorbed dose) in the air when using DRK-1M dosimeters.
Doza
Zelenograd
Produced in: Moscow
POWDIX 600 X-ray powder diffractometer
POWDIX 600 X-ray powder diffractometer
A feature of the POWDIX 600 X-ray diffractometer scheme is the vertical Bragg-Brentano optical scheme with a fixed horizontal sample position, which makes working with powdery materials, gels and other viscous substances more practical and convenient. The high detector resolution and precise positioning of the POWDIX 600 X-ray goniometer achieve an accuracy better than +/- 0.02° (2θ) over the entire angular range. In the POWDIX 600 diffractometer, the X-ray tube is cooled by an integrated closed water circuit, which can be serviced by any laboratory employee. A wide variety of sample holders (holder for massive samples, holder with rotation, phoneless cuvettes) expands the functionality of the POWDIX 600 and makes it an invaluable tool for scientific research in solid-state physics, materials science, chemistry, geology and other fields of science The diffractometer is included in the Russian State Register of Measuring Instruments.
Produced in: Belarus, Minsk
Dosimetric thermoluminescent complex "DOSE-TLD"
Dosimetric thermoluminescent complex "DOSE-TLD"
Purpose: measurement of the individual dose equivalent of Hp(10) photon radiation; measurement of the individual dose equivalent of Hp(10) neutron radiation; measurement of the individual dose equivalent in the skin Hp(0.07) and the lens of the eye Hp(3) of photon and beta radiation; measurement of ambient dose equivalent H*(10) of photon radiation.
Doza
Zelenograd
Produced in: Moscow
Individual thermoluminescent dosimeters
Individual thermoluminescent dosimeters
The principle of operation of dosimeters is based on the accumulation of ionizing radiation energy by detectors proportional to the radiation dose. In DVG-02TM installations, DOZA-TLD complexes, etc., when the detector is heated, the accumulated energy is released in the form of light radiation, which is recorded by an electronic device.
Doza
Zelenograd
Produced in: Moscow