Back to search results

EVRASAMP ESC Sampling with low carbon content

Back to search results
EVRASAMP ESC Sampling with low carbon content
Manufacturer:
EVRAZPRIBOR
Location:
Lipetsk
Appointment: Sampling for chemical, spectral, etc. analysis
of molten metal
Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc.
Type of sampler: Ceramic sampler with an elongated leg
Operating temperature range (depending on the type of sampler):
from 1150°C to 2020°C
Selection time: from 3 to 5 seconds
Tube Length: from 100 to 1500 mm (other lengths are available on request)
Slag Cap: Steel, Cardboard, Aluminum
Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium