Search

3941 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 550
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3941 products
Verification module PM-3
Verification module PM-3
The composition of the PM-3 verification module: Frequency comparator CHK7-1011; Universal frequency meter Ch3-86A; Universal voltmeter V7-79; Absorbed power wattmeter M3-108-2; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Generator of test pulses G9-1A; Oscilloscope S1-177; DC power supply B5-79/1; Electronic switchboard of RF signals; AC power source B2-7 (2 pcs.); PC, printer; Basic load-bearing structures (BNC). Technical specifications Measurement ranges of time-frequency parameters of signals: Continuous oscillation frequency from 0.005 Hz to 17.85 GHz Pulse repetition rate from 0.01 Hz to 100 MHz The carrier frequency of the IM signal is from 100 MHz to 17.85 GHz Pulse duration from 10 ns to 1000 s Time interval from 0 to 1000 s Nominal values of the frequency of the studied signals are 2,048; 5,0; 10,0; 10,24 MHz Measurement errors of time-frequency parameters of signals: Frequency of continuous oscillations ± (2,4·10-10 - 4·10-3) Pulse repetition rate ± (2·10-7 - 2·10-3) The carrier frequency of the IM signal is ± 2·10-7 Pulse duration ± (1 - 200) ns Time interval ± (1 - 200) ns The relative deviation of the frequency of the studied signal from the reference frequency ± (5·10-13 - 2·10-12) Frequency of continuous oscillations ± (3·10-11 – 1,1·10-5) Pulse repetition rate ± (2·10-11 – 6·10-5) Carrier frequency of the IM signal ± (3·10-11 – 1,1·10-5) Pulse duration ± (1·10-8 – 7,2·10-4) Time interval ± (2·10-10 – 7,2·10-4) Nominal values of the reference signal frequency ± (2·10-11 – 2,4·10-10) General technical characteristics: The area occupied by the module is 8-12 m2 Weight, not more than 327 kg Power supply voltage from 198 to 242 V frequency (50 ± 0.5) Hz Power consumption, no more than 2400 VA
Produced in: Moscow
Pure Hydrogen Generator GVCH-25D
Pure Hydrogen Generator GVCH-25D
from 300 000 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the capacity, respectively, is 25 liters/hour (416 ml/min). Technical specifications Purity of hydrogen in terms of dry gas about 99.998% The concentration of water vapor at 20 OC and 1atm is not more than 10 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse ± 0.02 ati Maximum hydrogen capacity, reduced to normal conditions is 25 l/h The time of setting the operating mode, with the output turned off is no more than 20 minutes In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 25 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is not more than 0.04 l/hour Water consumption is 2.4 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average power consumption: in stationary mode is no more than 200 VA maximum (at startup) is no more than 250 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
 Yellow DPSS Laser 604 nm KLM-604-x
Yellow DPSS Laser 604 nm KLM-604-x
DPSS lasers of the KLM-604/x series are diode-pumped solid-state lasers of the visible spectral range (604 nm) with collimated continuous radiation of low and high power (depending on the model). The package includes: a laser head, a power supply, a set of connecting wires, a power cable and a device passport. Depending on the tasks, the following options are available for each laser model: the presence of TTL modulation / the presence of analog modulation, power control via the power supply, the presence of a display for the power supply, improved power instability (<3% / <1%), improved temporary power instability (4 h / 8 h), radiation sweep in-line (5...120°), laser head with fiber output (FC/SMA), extended warranty period, custom housing development. These lasers are widely used in medical equipment, for control and automation of technological processes, in scientific research, astronomy, spectroscopy. They are optimal sources of coherent radiation for the construction of systems of alignment and marking devices.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with sodium citrate 3.2%, 1.8 ml,13*75 mm, blue, glass, pack.100 pcs
Vacuum tube MiniMed with sodium citrate 3.2%, 1.8 ml,13*75 mm, blue, glass, pack.100 pcs
from 1 284 ₽
The test tubes contain a buffer solution of sodium citrate, which is an anticoagulant. The ratio of citrate to the amount of blood taken is 1:9. Material for research............... citrate plasma, blood Scope of application............................ coagulation study Centrifugation................................ 2000 - 2500 g - 10-15 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Spring THERMOTEST holder-DP1-9/16
Spring THERMOTEST holder-DP1-9/16
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 9 to 16 mm. The design of the holder eliminates damage to glass thermometers. It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
Produced in: Tomsk
SPECTROMETERS MKS‑AT6101S, MKS‑AT6101SM
SPECTROMETERS MKS‑AT6101S, MKS‑AT6101SM
The best one in its class 20 hours of continuous operation Automatic simultaneous gamma-neutron radiation scanning with identification of radionuclides Permanent recording of GPS-linked scan data for subsequent analysis The possibility of expanding the measurement range of the ambient dose equivalent power to 10 Sv/h Software application "GARM" for expert data processing and analysis and radiation mapping The possibility of placing the spectrometer in a shockproof case (on request).
Produced in: Belarus, Minsk
PCR kits and mixes
PCR kits and mixes
from 2 100 ₽
Field of application: -Gene expression analysis -One-step standard RT-PCR -One-step standard RT-PCR and the use of fluorescent probes -One-step real-time RT-PCR with SYBR Green I fluorescent dye Advantages of use: -High specificity -High sensitivity -Easy and convenient to use -Low pipetting and cross-contamination errors -Standard conditions for the same type of reactions -The possibility of TA cloning of PCR products due to the amplified DNA fragments of deoxyadenosine residues protruding at the ends.
BIOLABMIKS
Novosibirsk
Produced in: Novosibirsk
Metal single support cabinet with 4 drawers LAB-PRO TOMYA4 86.50.86
Metal single support cabinet with 4 drawers LAB-PRO TOMYA4 86.50.86
Metal single support cabinet with 4 drawers Length, mm: 860 Depth, mm: 500 Height, mm: 860 Completely made of powder-coated steel (RAL 7035) with the texture of shagreen leather Frameless housing design One compartment with 4 drawers The side walls and facades are double. The thickness of the side walls is 19 mm, the facades are 18 mm The facades are filled with noise-absorbing material Handles - polypropylene Telescopic guides of full extension Internal size of the drawer: 770*410*85 mm The permissible load per box is 20 kg. Hidden adjustable supports (0 - 40 mm). The adjustment of the supports is carried out from inside the pedestal through the base of 8 standard variants of LAB-PRO RP work surfaces
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K3-EDTA, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
Vacuum tube MiniMed with K3-EDTA, 5 ml, 13×100mm, purple, PET, pack.100 pcs,
from 665 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... stabilized EDTA whole blood /EDTA plasma.
MiniMed
Suponevo
Produced in: Bryansk region
Vacuum drying cabinet with automatic control SNVS-210/3.5
Vacuum drying cabinet with automatic control SNVS-210/3.5
The series is designed for heat treatment according to pre-created programs. The presence of remote control and a number of software options allows you to use the product for long-term heat treatment modes. Vacuum drying cabinets can be used for: - gentle drying of thermo- and oxygen-sensitive substances, such as food, medicinal, cosmetic products; - complete removal of residual moisture from heat-sensitive components with a complex shape, such as components of electronic equipment, jewelry, watches and other precision mechanics; - removal of air when filling the molds with a compound, followed by solidification at a given temperature; - removing air from the product and replacing it with another necessary gas medium; - tempering, annealing or aging of metals with the appropriate processing temperature in a vacuum or protective environment; - drying of products after washing in flammable solvents (special version); - testing devices under low pressure conditions under various temperature conditions.
Produced in: Tula
High-frequency signal generator G4-227
High-frequency signal generator G4-227
The generator is capable of operating both independently and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 9 kHz to 6 GHz Frequency tuning discreteness of 1 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 10 to 13 dBm The basic error of setting the reference power level is ± (0.5 – 1.0) dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal from 1 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value) from 12.5 to 4000 kHz - the main error of the frequency deviation setting is ± (20 – 25)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 100 % - the basic error of setting the amplitude modulation coefficient ± (0.25 M + 0.2)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 300 ns to 20 s - the range of the modulating pulse repetition period from 340 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 200 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, not more than 100 VA Overall dimensions, mm 498x136x487 Weight, not more than 13 kg
Produced in: Moscow