Search

6 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 7
    Applying
  • 2
    Names
  • 3
    Manufacturer
  • 2
    Made in
  • Additional
View:
6 products
BOREY Laboratory Mill
BOREY Laboratory Mill
1 supp.
The mill provides grinding of grain crops according to the current standards regulating methods of determining their quality. The principle of operation: grain is fed into the mill dispenser, where an air-grain mixture is formed, which enters the grinding chamber. The crushed product is separated from the air in the cyclone and collected in a special removable container. After the grain supply is stopped, the air flow ensures self-cleaning of the dispenser and the grinding chamber of the mill. application It is used in the preparation of samples to determine the quantity and quality of gluten, the "drop number" and other indicators of the quality of crops by infrared spectroscopy and other laboratory analysis methods, which require a high degree of grinding of samples. GENERAL CHARACTERISTICS • High degree of grinding The mill is equipped with a sieve with round holes with a diameter of 0.8 mm*, which makes it possible to obtain a finely dispersed product with a stable particle size during grinding. *on a separate order, it is possible to complete a sieve with holes with a diameter of 1.0 mm • Quick and easy cleaning The ledges and holes in which the ground sample can be collected are minimized. • Low noise The optimized design of the mill body and the door of the grinding chamber with additional noise insulation ensure comfortable work of the staff during the working shift. • Large volume of the container for the ground sample The volume of the container for the ground sample is 1.4 liters. Thanks to this, it is possible to grind samples weighing up to 500 grams, which allows you to obtain more accurate test results and use the ground sample for simultaneous various analyses. • Dust-free grinding A fundamentally new design of the cyclone-container connection for the ground sample eliminates the possibility of dust entering the air. • Easy to operate The ergonomic handle of the retainer allows you to quickly and easily fix the container for the ground sample. technical specifications: Volume of the receiving funnel, 500 ml Permissible amount of ground product per hour, kg 5 The grinding time of the suspension is 50 gr., from 25-35 The maximum size of the crushed product, mm 12 The diameter of the sieve holes, mm 0.8; 1.0 The speed of rotation of the grinding hammers, rpm 16,800 Minimum mass of the milled product, g 10 The maximum mass of the milled product, 500 g Overall dimensions, mm 550 x 520 x 460 Weight, kg 50 Noise level, dB 70 Power supply Single-phase AC 220 V, 50 Hz Power, W 1100 The response time of the overload protection system, from 20
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
The device for monitoring the loading of mills UKZM-1
The device for monitoring the loading of mills UKZM-1
The device for monitoring the loading of raw materials and cement mills UKZM-1 is designed to monitor and indicate the degree of loading of raw materials and cement ball mills by an indirect signal associated with the state of the clinker or raw charge grinding process.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Laboratory mill BLIZZARD 3 MT
Laboratory mill BLIZZARD 3 MT
1 supp.
The principle of operation of the mill is based on grinding the product with a steel knife rotating at high speed in combination with cyclic rotation of the grinding unit. FEATURES: 1.Fast and high-quality grinding of solid products The high power of the electric motor in combination with a specially designed knife of a special shape and automatic cyclic rotation of the grinding unit of the mill at 210 and 90 makes it possible to qualitatively grind samples of solid products in a short time. It is possible to grind lump cake up to 20 mm in size. 2. Sample preparation without heating. Improved heat dissipation due to the design of the grinding cup, the outer surface of which has the appearance of a radiator, high grinding speed and the possibility of cooling the grinding bowl prevent possible overheating of the sample, which eliminates moisture loss and allows the mill to be used for sample preparation during analysis to determine the moisture content of products. They are part of the installation of the measuring air-thermal ASESH-8 (RU.C.31.005.A No. 56847). According to the test results of FSUE "UNIIM", the mills are recommended for sample preparation during the analysis to determine humidity. 3. COOLING SYSTEM without forced water cooling. For continuous comfortable operation with the cooling system, the mill is equipped with two grinding cups. 4. Quick and easy cleaning of the mill. A mode for grinding solid products with an improved cleaning system of the grinding chamber has been implemented. 5.Grinding headset with long service life The grinding set of the mill is specially designed to work in extreme conditions – high productivity and high mechanical load. Special inserts made of knife-hardened stainless high-strength steel with the effect of forging the grinding chamber and cup ensure long-term operation of the mill when grinding solid and granular products. The knife made of high-strength stainless knife steel guarantees their high wear resistance.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mill VYUGA-GMO
Laboratory mill VYUGA-GMO
1 supp.
GENERAL CHARACTERISTICS: • Possibility of cleaning and autoclaving of all parts of the grinding set The grinding chamber of the mill and all parts of the grinding set that come into contact with the sample can be easily removed for cleaning and autoclaving, which is an important condition for sample preparation in the determination of GMOs. • Minimal heating of the sample during grinding The special design of the grinding chamber and the use of special knives guarantee minimal heating of the laboratory sample, which eliminates the negative impact on the quality of the extracted DNA. • Grinding with the required quality and homogenization of the sample in one grinding step The ability to select the optimal combination of blade rotation speed, grinding time and automatic rotation of the grinding unit guarantees high-quality, fast grinding and homogenization of samples for various types of samples. • Reproducible grinding results Automation of the grinding process and digital time setting ensure high reproducibility of grinding results. • Easy operation with information display The mill is easy and convenient to operate. Time and grinding mode are set by one button. The information display will show the grinding process parameters. • Grinding of samples with high fat content (up to 55%) The automatic 210° and 90° automatic cycling of the grinding unit, combined with a high grinding speed, minimizes sample heating and oiling of the grinding chamber, which guarantees high-quality, fast grinding and homogenization of samples with a high fat content. 3 grinding chambers are included in the DELIVERY SET of the VYUGA-GMO mill. By separate order it is possible to purchase the required number of grinding chambers.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Laboratory mill BLIZZARD 3M
Laboratory mill BLIZZARD 3M
1 supp.
The principle of operation of the mills is based on the grinding of the product, rotating at high speed with a knife in combination with a cyclic rotation of the grinding unit. In order to achieve uniform grinding and homogenization of the sample, the grinding unit must be tilted during grinding. The angle of inclination is set automatically according to the selected mode. FEATURES: 1. Programmable grinding modes The laboratory mill has two grinding modes: "Sunflower" - used for grinding oilseeds. "Grain. Feed" is used for grinding grain, leguminous crops, feed and raw materials for their production. Depending on the crushed product, the operator selects the desired mode of the grinding process. The installation of the grinding mode options is carried out using a specially developed program via a PC. It is possible to install an additional grinding mode using a PC. 2.Easy operation with information display. 3. Crushing of samples with a high fat content (up to 55%). 4. Sample preparation without heating. The special design of the grinding chamber (grinding is carried out in the upper bowl made of aluminum) and the use of special knives ensure rapid grinding and minimize heating of the sample, which eliminates moisture loss. According to the test results of FSUE "UNIIM", mills are recommended for sample preparation during the analysis to determine humidity. They are part of the installation of the measuring air-thermal ASESH-8 (RU. p.31.005.A No. 56847). 5. COOLING SYSTEM without forced water cooling. For continuous comfortable operation with the cooling system, the mill is equipped with two grinding cups. 6. Grinding of various types of samples. The presence of knives of various geometries and the possibility of their quick replacement when changing the crushed product, allows the mill to be used for grinding a wide range of agricultural products – from wheat grains to soybeans and sunflower seeds, according to specially developed algorithms. Knives are included in the delivery package of the mill: knife No. 2 – for grinding oilseeds and cereals; knife No. 4 – for grinding feed and raw materials for their production; knife No. 1 – designed for chopping soybeans.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Laboratory Mill CALIBRE
Laboratory Mill CALIBRE
1 supp.
The mill provides grinding of agricultural crops according to the current standards regulating methods of determining their quality. Principle of operation: grain is fed into the mill dispenser, where an air-grain mixture is formed, which enters the grinding chamber. The crushed product is separated from the air in the cyclone and collected in a special removable container. After the grain supply is stopped, the air flow ensures self-cleaning of the dispenser and the grinding chamber of the mill. application It is used in the preparation of samples to determine the quantity and quality of gluten, the "drop number" and other indicators of the quality of crops by infrared spectroscopy and other laboratory analysis methods, which require a high degree of grinding of samples. The CALIBRE differs from its predecessor, the BOREY laboratory mill, by a drastic reduction in overall and weight characteristics. An additional advantage of the CALIBRE mill is the reduction in the number of structural elements. So the absence of the door of the grinding unit makes it possible for quick access to carry out work on cleaning the grinding headset. technical specifications: Volume of the receiving funnel, ml 400 Permissible amount of ground product per hour, kg 3 The grinding time of the suspension is 50 gr., from 25-35 The maximum size of the crushed product, mm 12 The diameter of the sieve holes, mm 0.8; 1.0 The speed of rotation of the grinding hammers, rpm 16 500 Minimum mass of the milled product, g 10 The maximum mass of the milled product, g 300 Overall dimensions, mm 400 x 445 x 400 Weight, kg 26 Noise level, dB 70 Power supply Single-phase AC 220 V, 50 Hz Power, W 1050 The response time of the overload protection system, from 2 GENERAL CHARACTERISTICS: 1. Reproducible sample preparation process: The mill is equipped with a sieve with round holes with a diameter of 0.8 mm*, which makes it possible to obtain a finely dispersed product with a stable particle size during grinding. On a separate order, it is possible to complete a sieve with holes with a diameter of 1.0 mm. 2. Quick and easy cleaning The cyclone-exhaust system of the mill provides self-cleaning of the grinding chamber. The ledges and holes in which the ground sample can be collected are minimized. 3. Low noise The vibration and noise insulation system of the CALIBRE mill allows, with considerable power and productivity, to ensure comfortable work of personnel during the working shift. 4. Maximum safety and ease of operation The closed grinding chamber ensures safe operation of the mill. The thermal overload protection system turns off the electric motor when it stops during the grinding process.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg