The set of devices is designed for installation in a vertical position of nine working viscometers in the bath of the VIS T 06 liquid thermostat when they are verified.
A height-adjustable pallet collects coolant droplets.
The collapsible design provides compact storage and quick assembly as needed.
Overall dimensions 355x200x405 mm
Weight 1.9 kg
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storing test tubes.
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storage of containers with a volume of up to 30 ml.
It is designed for installation of two working viscometers in the VIS T 11 liquid thermostat when they are verified or when determining the viscosity of petroleum products in accordance with GOST 33.
The tripod is made of aluminum, which allows them to be sterilized at any temperature; this material provides lightness and durability. It can be used in water baths. The tripod has an individual packaging. Designed for storing test tubes.
The set of devices is designed to install five working viscometers in a vertical position in the bath of the VIS T 06 liquid thermostat when they are verified.
The pallet, which is moved along the height, collects drops of coolant.
The collapsible design provides compact storage and quick assembly as needed.
Overall dimensions 500x200x405 mm
Weight 2.05 kg
The use of this tripod extends the functionality of thermostats for determining the viscosity of LOIP LT-910, LOIP LT-912 and allows for density determination tests in accordance with GOST 3900-85 and GOST R 51069-97, in the temperature range -42 ...150 ° C, with an accuracy of up to ± 0.01 ° C.
The tripod works with instruments:
LOIP LT-380
LOIP LT-910
LOIP LT-912
LOIP LT-810
It is used to connect TDS thermometers and MASTER thermostats equipped with an RS 485 interface to a personal computer via a USB interface.
The use of this adapter does not require the installation of additional drivers because it uses the HID driver built into the operating system to exchange data.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used еo ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
The holder with flat steel springs allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 16 to 20 mm.
It is designed for THERMOTEST 05 and THERMOTEST-05-1 thermostats.
Allows you to install and securely fix up to 6 verifiable thermometers with a diameter of the submerged part from 3 to 9 mm.
The design of the holder eliminates damage to glass thermometers.
It is designed for calibration thermostats THERMOTEST-100 and THERMOTEST-300.
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
A basket with a height-adjustable bottom allows objects to be immersed in the coolant to the required depth.
Overall dimensions 305x305x390 mm
Internal dimensions 260x250mm
Weight 3.1 kg
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.