Liquid thermostat VIS-T-06
Liquid thermostat VIS-T-06
Operating temperature range +20...+50 °C Nine places for reference viscometers. It is designed to work with reference viscometers, which capillary length is 300 mm. Overflow design ensures stability and uniformity of temperature not worse than ± 0.01 °C Bath volume 85 l Number of jobs 9 Overall dimensions 720x290x910 mm The open part of the bath is 440x190 mm Bath depth 590 mm The size of the viewing window is 440x530 mm Weight 45 kg Power consumption 2.2 kW
Produced in: Tomsk
MU-630 Enlarged oil reflector
MU-630 Enlarged oil reflector
The MU-800 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens to capture oil return flow vapors.
Produced in: Kazan
Sulfur and Metal Analyzer SPECTROSCAN MSW
Sulfur and Metal Analyzer SPECTROSCAN MSW
Technical Regulation TR CU 013/2011 "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and fuel oil" imposes requirements for the content of sulfur and metals in automotive fuel. The analyzer allows you to measure, in order to confirm the conformity of the fuel, according to the following indicators: mass fraction of sulfur, concentration of iron, manganese and lead. The analyzer implements an arbitration method for measuring the mass fraction of sulfur in automotive fuel of the third, fourth and fifth classes according to GOST R 52660-2006 / GOST ISO 20884-2016, and also allows you to measure the mass fraction of iron, manganese and lead. The MSW SPECTROSCOPE is designed taking into account the requirements for measuring low sulfur and metal contents in petroleum products. Meets the requirements for equipment and precision standards: GOST R 52660-2006 / GOST ISO 20884-2016, GOST R 53203-2008, GOST 33194-2014, ASTM D6334. The design of the analyzer allows it to be used in mobile laboratories. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the content of elements in the sample; - calculates convergence - the difference in determining the content of elements in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Thermostat for determining the density of LT-810
Thermostat for determining the density of LT-810
Technical specifications: Temperature range, °C - without external cooling (Current +10)...+100 - with tap water cooling (Tvody+5) +100 - with cryostat cooling LOIP FT-311-25 0 ...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of seats for cylinders 4 Cylinder dimensions (height*diameter), mm 500*50 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 30 Working fluid - up to 70 °C distilled water - above 70 ° C petroleum jelly or silicone oil, water-glycerin mixture Overall dimensions (WxDxH), mm 560x250x710 Weight of the device without liquid, not more than, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace LF-5/13-V1
Muffle furnace LF-5/13-V1
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Durable ceramic muffle; Semi-open heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x190 mm Overall dimensions, WxHxD, not more than mm 505x955x565 Rated supply voltage, 220 V Rated power, W 2800
LOIP
Saint Petersburg
Produced in: Saint Petersburg
MARK-2010
MARK-2010
Portable device for periodic measurement of the volume fraction of oxygen in various gases (hydrogen, natural gas, nitrogen, argon, helium, etc.). Mainly used for monitoring oxygen in the cooling circuit of generators, electrolysis plants, gas pipelines of boilers, monitoring the air of the working area. The warranty is 24 months for deliveries across the Russian Federation. High-precision measurement of oxygen microconcentrations Unique, patent-protected sensor design Exceptional selectivity to oxygen molecules Insensitivity to humidity, carbon dioxide, oil vapor Stable operation in a gas environment of any composition Ease of operation Automatic temperature and barocompensation The duration of measurements is 2-3 minutes Atmospheric air calibration Routine maintenance - no more than 1 time per year Built-in flow stimulator for forced sample delivery High contrast LED indicator IP54 housing case Protection from dust and moisture Built-in long-lasting battery At least 1000 charge/discharge cycles Carrying strap
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Optical Transceiver Gigabit Ethernet/Fiber channel (1.25Gbps)
Optical Transceiver Gigabit Ethernet/Fiber channel (1.25Gbps)
from 686 ₽
Optical transceivers are in standard SFP metal cases with a combined optical input/output for SC, LC connectors for transmitting a signal over a communication line - one optical fiber.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
 Portable kit for magnetic particle flaw detection Pole-M1
Portable kit for magnetic particle flaw detection Pole-M1
The Pole-M1 kit is used for monitoring pipelines, cranes, stanchions, beams and other ferromagnetic products, machine-building parts and workpieces for the presence of surface and subsurface defects (cracks, shells, etc.). It is designed to work in workshop, laboratory and field conditions. A permanent magnet allows you to monitor various shaped parts, welds and various products for cracks, discontinuities, shells and similar defects by magnetizing individual controlled areas or the product as a whole. The permanent magnet as part of the Polyus-M1 set of highly stable magnets with high maximum specific magnetic energy is designed to detect surface and subsurface defects in products made of ferromagnetic materials by magnetic powder or magneto-luminescent method and refers to portable specialized means of magnetic control.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Liquid thermostat VT-ro-01
Liquid thermostat VT-ro-01
Operating temperature range +15...+100 °C All-metal bath. Basket for placing six cylinders for hydrometers. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. The volume of the bath is 30 liters Overall dimensions 340x280x800 mm The open part of the bath is 120x210 mm Bath depth 500 mm Weight 23 kg Power consumption 2.2 kW
Produced in: Tomsk
Trace searcher with the function of saving GPS/GLONASS coordinates Success AG-309.60K
Trace searcher with the function of saving GPS/GLONASS coordinates Success AG-309.60K
from 282 210 ₽
A trace searching kit for finding underground utilities (cable lines, metal pipelines, and other communications made of conductive materials). As part of the kit, the receiver is in the form of a monoblock with a large LCD display, which displays an image of the route and automatically calculates the depth of communication up to 10 m, as well as the current in the line. Built-in GPS\GLONASS module for determining and recording the coordinates of the location of communication. "Probe" mode for tracing NON-METALLIC communications using an in-tube generator (optional). The generator has increased power up to 180 watts and a range of up to 5 km. Connection to the desired route is possible both by contact and contactless method.
Produced in: Kolomna, Moscow region
LT-840 Aging water bath
LT-840 Aging water bath
Design features: The microprocessor-based PID controller allows you to maintain the temperature of the coolant with an accuracy of ± 0.1 ° C. The built-in paddle agitator (1400 rpm) ensures efficient mixing of the working fluid. Bright LED digital display, displays the current and set temperature with a discreteness of 0.1 ° C. A cooling heat exchanger connected to the water supply to reach temperatures below room temperature. Multifunctional control knob. The working bath, made by stamping stainless steel, is characterized by a long service life and convenience when cleaning. Technical specifications: Temperature range, °C without external cooling (Current +10)...+100 with tap water cooling (Tvody+5)...+100 Accuracy of temperature maintenance, no more than, ° C ± 0.1 Power consumption, max., W 2200 Power supply 220±20 V, 50 Hz Working fluid water, water-glycerin mixture Number of jobs 6 Overall dimensions, mm 355x335x350 Bath volume, l 12 Weight, kg 11.9
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with manual control SNVS-145/5
Vacuum drying cabinet with manual control SNVS-145/5
from 940 810 ₽
The SNVS-145/5 vacuum drying cabinet with a volume of 145 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 500 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula