Equipment

2244 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 388
    Item names
    Loading...
  • 125
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 98
    Additional
    Loading...
View:
2244 products
LB186 Laboratory bath
LB186 Laboratory bath
It is designed to solve temperature control problems that do not require high accuracy of maintaining the temperature of the coolant and the uniformity of the temperature field in the working volume. Laboratory bath LB186 is characterized by simplicity of design, ease of use, reliability and low cost in comparison with liquid thermostats. Bath volume 140 l Overall dimensions 1150x570x480 mm The open part of the bath is 1060x430 mm Bath depth 300 mm Weight 58 kg Power consumption 2.5 kW
Produced in: Tomsk
Vacuum Drying Cabinet
Vacuum Drying Cabinet
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 0.05 mm Hg SHSV-65V/3.5
Laboratory vacuum drying cabinets SHSV residual pressure in the chamber 0.05 mm Hg SHSV-65V/3.5
The electric vacuum drying cabinet SHSV-65V/3.5 is designed for drying and heating various materials in air and in vacuum at a maximum temperature of 350 ° C. In the model with the index "C", the door is made of heat- resistant glass. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C Operating temperature- 350 ⁰C Power consumption - 2500 W Dimensions of the working chamber-Ø430x430 mm Dimensions WxDxH- 680x950x670 mm Weight - 115* kg (* - mass with microprocessor unit and pump)
MIUS
Tula
Produced in: Tula
Aquadistillator electric DE-210
Aquadistillator electric DE-210
from 430 000 ₽
Purpose: obtaining distilled water of 3 types according to GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Capacity: 210.0 (-10%) l/h Heating elements: electrodes The quality of the produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current, frequency, voltage: alternating, three-phase, 50 Hz, 380 V Power consumption: 128.0 kW Overall dimensions (L×W×C), mm: 1195x850x1915 Weight: 208 kg Warranty period: 12 months from the date of sale Registration certificate for a medical device No. FSR 2008/03707 dated December 05, 2008 Electrical conductivity of the produced water: 3-4.5 microns/cm The temperature of the produced water: 50 °C Source water flow rate (at 10 °C water temperature): 1800 (±10%) l/h Source water pressure: 0.1-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 650×250×800 Execution: Outdoor Coefficient of water purification from radionuclides: at least 4000 Service life: at least 8 years
Livam
Belgorod
Produced in: Belgorod
Chamber low–temperature electric resistance furnace CHO-5.5.6/5-In
Chamber low–temperature electric resistance furnace CHO-5.5.6/5-In
Designation: SNO–5.5.6/5-In Power supply: 380+N+PE Power: 18 kW Temperature: 500 Camera size (SHGV): 500x500x600 Door opening: manual Regulation zones: 2 Fan: Yes
Produced in: Tula
Precision thermostatic bath LB-217
Precision thermostatic bath LB-217
Technical specifications: Temperature range, °C without external cooling (Current+10)...+100 with tap water cooling (Tvody+5)...+100 Accuracy of temperature maintenance, not more than, ° C ± 0.1 Power consumption, max., W 2200 Power supply 220±20 V, 50 Hz Working fluid water, water-glycerin mixture Dimensions of the working part of the bath / depth, mm 360x296/150 Overall dimensions, mm 532x335x350 Bath volume, l 17 Weight, kg 14,5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210/510
Laboratory scales VLTE-210/510
from 77 490 ₽
Technical specifications: NIP, g210/510 Discreteness, g0,001/0,01 External calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02/0.5 The price of the verification scale division, mg10/100 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5/±50; St. 50g to 200g incl. ±10/±50; St. 200g to 210g incl. ±15/±50; St. 210g to 500g incl. ±50; sv. 500g to 510g incl. ±100 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high The setting time, s, no more than ~3 /~2 Weight adjustment 200gF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
NVR-0,1D Plate-rotary vacuum pump
NVR-0,1D Plate-rotary vacuum pump
Pumping out steam-gas mixtures is allowed only when the gas-ballast device is open. The NVR-0,1D vacuum plate-rotary pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-021-00218526-2001, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 53390-2009.
Produced in: Kazan
Liquid thermostat VT-R-02
Liquid thermostat VT-R-02
The operating temperature range is +20...+100 °C. Two workplaces for placing prepared Raid bombs with pressure gauges. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. The volume of the bath is 30 liters Overall dimensions 335x280x800 mm The open part of the bath is 120x210 mm Bath depth 500 mm The size of the viewing window is 190x480 mm Weight 25 kg Power consumption 2.2 kW
Produced in: Tomsk
MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
Scope of application · measurement of electrical energy parameters in three-phase or single-phase current networks with their subsequent transmission to the upper level of the AIS · the device of the lower level in the AIS at the facilities of generation, conversion, transmission and distribution of electricity
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Furnace for heating in a protective environment CHO (3)-40/11
Furnace for heating in a protective environment CHO (3)-40/11
from 1 493 400 ₽
Designation SNO(H)-40/11 Power, kW, no more than 8 Supply network voltage, V 380 Frequency, Hz 50
Produced in: Tula