Liquid thermostat THERMOTEST-100
Liquid thermostat THERMOTEST-100
The operating temperature range is -30...+105 °C. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C without the use of a leveling unit. Bath volume 13 l Overall dimensions 450x700x810 mm The open part of the bath is 90 mm Bath depth 430 mm Weight 70 kg Power consumption 3.5 kW
Produced in: Tomsk
Laboratory electric furnace CHO-40
Laboratory electric furnace CHO-40
from 347 688 ₽
Designation SNO-40 Volume, l 40 The material of the working chamber is ceramic Heating 4 sides Power consumption, W, max 10000 Minimum operating temperature, 0C 100
Produced in: Tula
3VVN2-50 Water ring vacuum pump
3VVN2-50 Water ring vacuum pump
The 3VVN2-50(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN2-50(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
The bath for checking ariometers VPA
The bath for checking ariometers VPA
Allows you to simultaneously place up to 4 hydrometers and a thermometer. A low-temperature liquid thermostat is additionally required to ensure the temperature of the calibration liquid of 20 ±0.05 °. Overall dimensions 500x380x650 mm The open part of the bath is 135 mm Bath depth 490 mm Weight 27 kg
Produced in: Tomsk
Whiteness meter BARS
Whiteness meter BARS
1 supp.
The principle of operation is based on measuring the zonal reflection coefficient of a compacted-smoothed flour surface using a built-in standard. The laboratory white meter BARS is approved as a type of measuring instruments and is registered in the State Register of Measuring Instruments under No. 78409-20. All manufactured devices undergo primary verification and have the appropriate certificate. Due to the two-channel design of the device (the presence of two photometric units and a cuvette with two cells), parallel measurements of the whiteness of one flour sample are carried out simultaneously, the average value is calculated automatically, which significantly reduces the time of analysis. The sealing of the flour sample with a fixed force and pressing against the optical windows ensures the same measurement conditions and eliminates the influence of a subjective factor on the result. The automatic adjustment system based on the built-in standard allows to ensure long-term stability of the device without the need for manual adjustment. During operation, the standard is set to the working position by an additional drive. Mechanical damage or loss of the standard is excluded. The output to the operating mode is no more than 30 seconds. The determination of whiteness is carried out in 15 seconds. To determine the whiteness of flour, the operator needs to fill 2 compartments of the cuvette with the test sample of flour, install the cuvette in the device and start the measurement process. All the results of the whiteness definitions are stored in the archive. The operator has the opportunity to view the electronic measurement log.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
pH meter MARK® 902 MP
pH meter MARK® 902 MP
Measurement of hydrogen ion activity (pH) and temperature of aqueous media. pH control of water media in technological processes, including treatment facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Calibration according to standard buffer solutions with their automatic determination. Universal trunk-submersible "active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
 Magnetometer - Residual magnetization meter ION-3701
Magnetometer - Residual magnetization meter ION-3701
from 57 245 ₽
The small-sized digital magnetometer (Gaussmeter, teslameter), ION-3701 residual magnetization meter is a modern high-precision instrument, a further development of ION series devices (ION-1, ION-2, ION-2M, ION-7) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization. It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Vacuum drying cabinet SNVS-50/5
Vacuum drying cabinet SNVS-50/5
They are designed for carrying out various technological processes at temperatures from 40 to 500 oC, in vacuum up to 1x10−3 mmHg, or in an inert gas of high purity. They are used for drying, light annealing, aging, low and medium tempering in an oxidizing environment, degassing of ferrous and non-ferrous metals (including copper and copper alloys), or any other materials processed under similar conditions. The program setting of heat treatment modes including vacuuming, high purity inert gas intake with repeated vacuuming allows heating in an oxidizing environment with high purity of the surfaces of the processed parts, without scale formation and oxidation.
Produced in: Tula
Laboratory drying cabinet SNOL-7.4.7/1,0- I2-In
Laboratory drying cabinet SNOL-7.4.7/1,0- I2-In
from 465 634 ₽
Laboratory Low-temperature Precision Drying Cabinet SNOL-7.4.7/1,0- I2-B is designed for long-term heat treatment (and storage) in a stirred air environment at temperatures up to 100 ° C.
Produced in: Tula
Apparatus for determining resins by evaporation by air jet TOS-LAB-02
Apparatus for determining resins by evaporation by air jet TOS-LAB-02
Technical specifications: The range of set unit temperatures, °C from +50 to +250 Accuracy of temperature maintenance, °C ± 1 Time to reach a temperature of 162 ° C, no more, min. 40 Air consumption, l/min 180±32 Voltage, 220 V Power, W 2000 Overall dimensions, mm 410x305x250 Weight, kg 20
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Nitrogen generator GA-400
Nitrogen generator GA-400
from 408 000 ₽
Nitrogen generators are designed to create an inert atmosphere, fill low-pressure tanks and other applications that require a large, by laboratory standards, nitrogen consumption with reduced requirements for its purity. The warranty period of operation of the generator is 12 months from the date of sale by the manufacturer. Technical specifications Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.5 Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity is at least 400 l/h (6.66 l/min) The time of setting the operating mode for single-shift operation is no more than, min, 30 Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3000 l/h (50 l/min) Power consumption is not more than 100 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm; Weight is not more than 30 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow