Leakage detector Success AT-207
Leakage detector Success AT-207
from 99 360 ₽
The kit of the portable acoustic leakage detector "Success AT-207" is designed to detect depressurization sites of underground pipelines of heat and water supply systems located at a depth of up to 3 m in channel and channel-free laying. The search for damage sites is carried out by the acoustic method. •
Produced in: Kolomna, Moscow region
GAS PANEL
GAS PANEL
The gas distribution panel (hereinafter referred to as the panel) is designed to connect gas nodes and blocks of various analytical instruments, including chromatographs to shop gas lines. technical specifications Inlet pressure, not more than 0.8 MPa. The output pressure is from 0 to 0.4 MPa. Gas flow rate through each channel, not less than — 1000 cm3/min.
Produced in: Yoshkar-Ola, Mari El
High pressure gas flow regulator RRG-VD
High pressure gas flow regulator RRG-VD
It can be used as a primary source of carrier gas, since it is equipped with an additional gas purification system. This device is especially relevant when, for some reason, helium is not available to the consumer (for example, when working with a thermal conductivity detector - an accident). Due to the high thermal conductivity of hydrogen, TTP operates with significantly greater sensitivity than helium.
Produced in: Yoshkar-Ola, Mari El
METANATOR
METANATOR
To analyze small concentrations of carbon monoxide (CO) and carbon dioxide (CO2), instead of the usual catarometer for these gases, a more sensitive PID is used, while carbon oxides are converted into methane (CH4) using reaction chromatography. The device implementing the conversion reaction is called a methanator, i.e. a device with a special catalyst that converts CO, CO2 into methane in a hydrogen current, while the latter is either a carrier gas itself, or is blown together with the carrier gas into the methanator through a tee. The methanator provides a highly efficient conversion reaction, while the detection limit of carbon oxides reaches 0.1 ppm. technical specifications Metanation temperature — 330 °C The coefficient of metanation is not less than 95 % The effective volume of the methanator is 1 ml.
Produced in: Yoshkar-Ola, Mari El
CRYOCONCENTRATION DEVICES
CRYOCONCENTRATION DEVICES
To determine small concentrations of substances, in some cases it is impossible to do without their concentration in special traps. An example of the need for such concentration is the determination of impurities in permanent gases (Ne, He, H2, Ar, O2, N2, Kr, Xe), the concentration of impurities is less than 1 ppm. Considering that these impurities can be not only hydrocarbons, but also permanent gases themselves, the use of direct detection of impurities by a catarometer is impossible. It is also not always possible to use highly sensitive but expensive detectors (GID, EDD, etc.). TECHNICAL CHARACTERISTICS The volume of the trap is 5 ml. The volume of the Dewar vessel (serial metal thermos) is 1200 ml. The concentration temperature range is from minus 88.6 (ethane) to minus 269 °C (helium). The ability to calibrate the chromatograph from the cylinder without disturbing the gas circuit. The possibility, simultaneously with concentration, to purify the gas intended for purging the trap from impurities (in a similar trap). Overall dimensions, no more than — 290 ×470 × 615 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
GEYSER-2A DEVICE
GEYSER-2A DEVICE
The Geyser –2A measuring and computing complex is designed to determine the dynamic characteristics and energy efficiency (caloric content) of various substances, including special products (gunpowder, explosives). The device also allows you to determine the chemical resistance of substances by the delay of the ignition time. The analysis is carried out in a given volume in the isothermal mode or in the temperature programming mode. technical specifications Operating temperature range in the reactor, from +50 to +600 ° C. The programming speed of the thermostat temperature in the operating temperature range, no more than 10 ° C. The limit of the permissible absolute error of setting the temperature of temperature control, no more than ± 2 ° C. Instability of maintaining the set temperature in the thermostat for 10 minutes, no more than ± 0.1 ° C. Sampling rate of the optical recording system, at least 25kHz The range of measurement of the ignition delay time in the isothermal mode, from 0 to 600 seconds. The measurement range of dynamic characteristics in the temperature programming mode, from 0 to 3600 sec. The continuous operation time of the device is at least 24 hours. The time for the device to enter the mode from the moment it is turned on, no more than 0.2 hours. The device is powered by AC 220V,+10/-15%,(50±1) Hz. The power consumption of the device, no more than 200 watts. The weight of the device without packaging, no more than 7 kg. Overall dimensions (width × depth × height), no more than 330×265×170 mm.
Produced in: Yoshkar-Ola, Mari El
CRYOSTATING DEVICES
CRYOSTATING DEVICES
The separation of some substances (the classic case is the separation of oxygen and argon) requires negative temperatures of the thermostat of chromatographic columns. technical specifications The lower temperature limit of the thermostat of columns with a cooling device based on an air conditioner is minus 5 °C. The error in maintaining the temperature of the thermostat of columns with a cooling device based on an air conditioner is + 0.05 °C. The power consumption of the cooling device based on an air conditioner, no more than — 640 VA. Overall dimensions of the cooling device based on the air conditioner, (width × depth × height), no more than — 620×480× 410 mm. The weight of the cooling device based on the air conditioner, no more than 32 kg. The lower limit of the temperature of the thermostat of columns with a liquid nitrogen cryoclap is minus 100 °C. The error of maintaining the temperature of the thermostat of columns with a liquid nitrogen cryoclave (in the temperature range less than 25 °C) + 0.1 °C. The power consumption of a cooling device with a liquid nitrogen cryoclave, no more than — 10 VA. Consumption of liquid nitrogen, not more than 0.1 l/h.
Produced in: Yoshkar-Ola, Mari El
CRYOEXTRACTOR EVC-2
CRYOEXTRACTOR EVC-2
The device is designed to extract target organic substances from liquid and solid samples. Implements the latest method of sample preparation in chemical analysis - extraction freezing with centrifugation of EVCB (Patents of the Russian Federation RU2303476/2007, RU2564999/2015, Patent of the Kyrgyz Republic KG388/2020, International Application PCT/RU2015/000615). Scope of application - hydrochemistry, chemical and toxicological analysis, biochemistry, food research, etc. technical specifications The temperature range of extraction freezing with centrifugation is from -(minus) 28 to +25 °C. Rotor speed with the possibility of programming the mode 100-8000 rpm Separation factor up to 6600 g Cryoextractor power supply from AC 220 V, 50 Hz Power consumption, not more than 0.3 kW The mass of the cryoextractor is not more than 50 kg Overall dimensions (HxWxD), mmxmmxmm no more than 900x600x600 Number of simultaneously extracted samples (individually on request)
Produced in: Yoshkar-Ola, Mari El
GAS FLOW SHAPER
GAS FLOW SHAPER
The gas flow shaper (FGP) is designed to automate the old fleet of chromatographs of the LHM type, model-3700, "Color" series, etc. in terms of setting and regulating the flow and pressure of both the carrier gas and auxiliary gases. The FGP has a flexible structure and provides regulation of gas flows from two to four independent gas flow channels and up to three pressure channels. The gas pressure at the inlet is (0.4 ± 0.04) MPa. The operating flow ranges of the carrier gas are from 3 to 250 ml/min with a discreteness of 1 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). The ranges of hydrogen consumption are from 3 to 250 ml/min with a discreteness of 1 ml/min. The air flow ranges from 10 to 750 ml/min with a discreteness of 1 ml/min. Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. Deviation of the carrier gas flow rate from the average value of ± 1.5% in the flow range from 50 to 100 ml/min and ± 0.5 ml/min in the flow range from 3 to 50 ml/min. The relative deviation of the average steady-state gas flow rate from the set value in the range: from 3 to 100 ml/min. ± 2.5%, but not less than 0.5 ml/min.; from 100 to 200 ml/min. ± 5%; from 200 to 800 ml/min. ± 10%. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption, no more than — 30 VA. Overall dimensions of the FGP (width × depth × height), no more than 160 × 370× 210 mm. Weight, not more than — 8 kg.
Produced in: Yoshkar-Ola, Mari El
DIGITAL MULTICHANNEL LEAK
DIGITAL MULTICHANNEL LEAK
The Meta-chrome digital gas flow meter is designed to maintain a given pressure and the ratio of the amount of gases (in the flow mode) or gas flow (in the intake mode) in vacuum installations with automatic and manual control. technical specifications The number of control channels is 2 (or more on request). The maximum flow rate for each of the channels is 700 cm3/min. The possibility of using gas correction coefficients, the most commonly used gases are listed in the leaker database. The accuracy of maintaining a given proportion of gases is 5%. The accuracy of maintaining the specified gas flow rates is 3%. Input pressures from 1 to 4 atm. Electric power supply from a single—phase AC network with voltage from 187 to 242 V, frequency (50 ± 1) Hz, operating mode - continuous. Power consumption (without a personal computer), no more than — 30 VA. Overall dimensions (width × depth × height), no more than 165×350×215 mm. Weight, not more than 5.5 kg.
Produced in: Yoshkar-Ola, Mari El
SYRINGE FILLING DEVICE
SYRINGE FILLING DEVICE
When analyzing gases dissolved in transformer oil using the ARP method (equilibrium vapor analysis), it is necessary to first fill a syringe with transformer oil with a carrier gas, and then, after achieving an equilibrium distribution of gases dissolved in oil between the liquid and gas phases, introduce the gas phase into the chromatograph (blow out the doses of the chromatograph dispenser tap). Moreover, the operations of filling the syringe and entering the sample are performed without air access. When filling the syringe, it is possible to fix the syringe stem at a certain volume. technical specifications The volume of syringes is 20 or 50 ml. The pressure at the outlet of the syringe filling line with argon is 0.5 atm. The range of ratios of volumes of the gas phase and oil (Vg/Vm) is from 0 to 1.5.
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolytic gas chromatography method is widely used in the study of polymer materials, plastics, rubbers, rubbers, paints and other high-molecular compounds of natural and artificial origin. The method is based on thermal decomposition of sample samples in an inert medium (without oxygen access), followed by chromatographic separation and analysis of the formed volatile compounds. Thus, the resulting pyrogram allows us to judge the composition of the original sample. Pyrolysis is also used in geochemical studies. Technical specifications The volume of the capsule is 56 ml. Pyrolysis temperature — from 200 to 1000 °C. The error of maintaining the temperature is not more than 1.0 ° C. The heating time of the sample to the pyrolysis temperature is no more than 2 seconds. The cooling time of the capsule when moving from the hot zone to the cold zone after pyrolysis is no more than 10 seconds. The time of continuous operation in the pyrolysis mode is no more than 60 seconds. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Power consumption — no more than 100 VA. Overall dimensions of the control unit (width ×depth×height) — 210×190×100 mm. Overall dimensions of the input node (width× depth×height) — 90×135×160 mm. The weight of the control unit is not more than 2.5 kg. The weight of the input node is not more than 0.9 kg.
Produced in: Yoshkar-Ola, Mari El