Equipment

2279 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 393
    Names
    Loading...
  • 124
    Manufacturer
    Loading...
  • 56
    Made in
    Loading...
  • 90
    Additional
    Loading...
View:
2279 products
MU-500 Oil reflector enlarged
MU-500 Oil reflector enlarged
The MU-500 flanged enlarged oil reflector performs the function of an oil reflector, is installed instead of a standard oil reflector in ND pumps and has an additional number of cooled screens for capturing oil return flow vapors.
Produced in: Kazan
LB12 Laboratory bath
LB12 Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. One workplace with a diameter of 110 mm with five steel O-rings. Stamped steel bath with a volume of 3.5 liters and a depth of 100 mm. Bath volume 3.5 l Overall dimensions 325x195x310 mm The open part of the bath is 235x130 mm Weight 6 kg Power consumption 2.5 kW
Produced in: Tomsk
Halogen leak detector "GTI-8"
Halogen leak detector "GTI-8"
It is designed to search for leaks of freons and other halogen-containing gases, for example, gas, in working equipment, and when testing systems, including cable ones, for tightness. The GTI-8 halogen leak detector also allows detecting an increase in the concentration of such gases in the room or near the controlled object. Technical characteristics of the leak detector "GTI-8" Parameter Sensitivity of the leak detector GTI-8, m3 Pa/sec., not less 1.0 - 5.3/10e-7 Time constant, sec., no more 3 Compensation of the initial sensor current Availability Automatic background signal compensation Availability Adjustable trigger threshold Availability Food ~220V, 50Hz (14.8V for GTI-8B) For modification of GTI-8B, continuous operation time, hour, at least 8 Operating mode setting time, min, no more 5
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
Immersion thermostat circulator LT-400
Immersion thermostat circulator LT-400
Designed to maintain the set temperature of objects in the bath, as well as for thermostating external systems: laboratory reactors, measuring cells of refractometers, viscometers, electrochemical analyzers, etc. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, no more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, (l/min) 6...12 pressure, (bar) 0,4 The working fluid is water, silicone oil. Dimensions, mm 115x240x305 Weight, kg 5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace MIMP-21M
Muffle furnace MIMP-21M
The furnace can be used as a universal laboratory muffle furnace in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications The furnace operates at ambient temperatures from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. The designation of the furnace when ordering: muffle furnace MIMP-21M, where 21 indicates the volume of the working chamber of the furnace in liters. Power consumption - 6000 W Dimensions of the working chamber W×D×B – 305×300×230 mm Dimensions W×D×B – 460×580×600 mm Weight – 80 kg
MIUS
Tula
Produced in: Tula
Heat exchanger TO-290/ TO-145
Heat exchanger TO-290/ TO-145
It is used in technological processes of nuclear, thermal and electric power plants, boiler houses and other facilities for cooling samples supplied to automatic and manual chemical control devices.Easy-to-clean collapsible structure. Materials with high mechanical properties are used: the coil is made of 316 SS steel, the body is made of 304 steel (or 12X18H10T). It is equipped with crimp fittings for connecting sample lines without welding. It is equipped with a special three-way ball valve for supplying / draining cooling water and a control valve that provides a change in the flow of cooling water through the heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
Collection for storage of purified water S-500
Collection for storage of purified water S-500
from 120 000 ₽
Designed for collecting, storing and distributing purified water obtained by various purification methods, with a capacity of 500 liters and 100% stainless steel, which allowed for a long service life. Dimensions in terms of 805x780 mm Weight 48 kg
Livam
Belgorod
Produced in: Belgorod
PLKS-02 Heating plate
PLKS-02 Heating plate
Laboratory heating plate with two heating sections and with the possibility of setting the temperature and heating time. The heating platforms are made of glass-ceramic. The size of the total heating surface: 440x284 mm. Heating temperature: 40-500 oC.
Produced in: Tomsk
Cable Finder Success KBI-306N
Cable Finder Success KBI-306N
from 75 600 ₽
Description of the cable finder Success KBI-306N • – Traceroute receiver in the form of a monoblock with LED indication and sound output to the built-in speaker. • – Automatic calculation and display of the depth of communication up to 10 m. Purpose of the cable finder Success KBI-306N • – Search for live electrical cables. • – Search and tracing of underground utilities (gas pipelines, pipelines, power and telephone cables). • – Determination of the occurrence of underground utilities at a depth of up to 10 m. Features of the AP-017N receiver • – Modern digital traceroute receiver-monoblock. • – Bright LED indicator. • – Displays the measured depth value on the screen. • – Determination of the deviation from the axis of the route by the LED indicator and the sound signal. • – Wide range of operating frequencies (50 / 100 / 512 / 1024 / 1450 / 8192 / 8928 / 9820 Hz, Wide Band 12...24 kHz). • – Frost-resistant, working at temperatures up to -40 ° C.
Produced in: Kolomna, Moscow region
POZIS STANDARD STAMPS Tablet press
POZIS STANDARD STAMPS Tablet press
Productivity, thousand tab./hour 140 Number of stations 31 Max. pressing force, tn 10 Number of threads 1 Diameter of tablets, mm 6-25,4 Height of tablets, mm 10-16 Matrix filling depth, mm 26 Rotor material steel 40x13 Filling hopper capacity, l 50 Changing the rotation speed of the rotor with a variator The change in the rotation speed of the feeder: forced Supply voltage 380V, 50Hz Power consumption, kW/hour 4.18 Weight, kg 2200 Dimensions, mm 900x900x1800
POZIS
Зеленодольск
Produced in: Zelenodolsk, Tatarstan
Liquid low-temperature thermostat CRYO-VIS-T-01
Liquid low-temperature thermostat CRYO-VIS-T-01
Operating temperature range 0...+50 °C Two places for glass viscometers. Stability and uniformity of temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 12 l Overall dimensions 440x710x620 mm The open part of the bath is 165x85 mm Bath depth 300 mm The size of the viewing window is 130x270 mm Weight 55 kg Power consumption 3.5 kW
Produced in: Tomsk