Metrology

525 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 23
    Applying
    Loading...
  • 194
    Names
    Loading...
  • 53
    Manufacturer
    Loading...
  • 31
    Made in
    Loading...
  • 55
    Additional
    Loading...
View:
525 products
Frequency meters H3-96
Frequency meters H3-96
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 3200 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz The number of averages. the period of the input signal is 1 ... 105 Borehole measurement by inputs – 1.000001- 999999999 Frequency ratio in channels: A/S, C/A, B/C and B/A - up to 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 2•10-8 - in 30 days, ± 5•10-8 - in 12 months Overall dimensions (HXHL) - 345x285x106 mm Weight: 4 kg Reference generator: ±5x10-8 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M
DOSIMETER‑RADIOMETER MKS‑AT1117M
Depending on the set of detection units, the device is designed to measure: - ambient dose equivalent and ambient dose equivalent power of X-ray, gamma and neutron radiation; - kerma and kerma power in the air; - the directional dose equivalent and the power of the directional dose equivalent of continuous X-ray and gamma radiation; - the flux and fluence densities of alpha and beta particles from contaminated surfaces; - the flux and fluence densities of neutron radiation with a known energy distribution; - surface activity and number of decays of 239Pu and 90Sr + 90Y; - operational search for sources of ionizing radiation and radioactive materials.
Produced in: Belarus, Minsk
Periodic control stand "SEC"
Periodic control stand "SEC"
Purpose: sampling for aerosol analytical filters of the AFA RSP-20 type control of the flow of gaseous mixtures in the sampling path Features: a rack with a sampling line fixed on it, an FD-1D filter holder and a rotameter.
Doza
Zelenograd
Produced in: Moscow
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Laboratory electronic thermometer LTA-N
Laboratory electronic thermometer LTA-N
The error is ± 0.05 °C in the range of -50...+300 °C. The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk