Smart air probe L=1000 mm SSV.1000P with built-in flash memory
Smart air probe L=1000 mm SSV.1000P with built-in flash memory
from 14 214 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object The smart air probe L=1000 mm SSV.1000P with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. Android program is installed. Operating conditions of the SZV.1000P smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSV.1000P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Navigation Systems Receiver module
Navigation Systems Receiver module
On the two high-frequency outputs of the receiver board, the signals of the second mark of the navigation receiver and the RF, which are available for the customer`s use, are generated. When receiving signals from satellites of the GLONASS and GPS radio navigation systems, the board ensures the operation of the RF in the frequency binding mode according to the signals of the second timestamp (the so-called “disciplined” rubidium frequency standard mode) with an error of the actual value of the RF frequency for no more than ± 5.10-12
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Smart probe of relative humidity and temperature L=500 mm SSVL.500
Smart probe of relative humidity and temperature L=500 mm SSVL.500
from 15 801 ₽
The smart probe of relative humidity and temperature L=500 mm SSVL.500 is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.500 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.500 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
Smart probe for connecting an external thermoelectric converter of the CVT
Smart probe for connecting an external thermoelectric converter of the CVT
from 10 626 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. The smart probe for connecting an external thermoelectric converter is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the smart probe of the SSVT Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe of the SSVT Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor.The Android program is installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
A small-sized economical device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. A unique combination of economy, speed and usability Working time without replacing batteries (2 x AA): AT2140 - 5000 hours, AT2140A, A/1 - 10000 hours Search mode USB interface and software for configuring the dosimeter and viewing the measured information (AT2140A/1)
Produced in: Belarus, Minsk
Liquid low-temperature thermostat CRYO-VIS-T-07
Liquid low-temperature thermostat CRYO-VIS-T-07
Operating temperature range +10...+60 °C Five places for glass viscometers. The stability and uniformity of the temperature in the working bath is not worse than ± 0.01 ° C. Bath volume 20 l Overall dimensions 620x400x970 mm The open part of the bath is 240x170 mm Bath depth 300 mm The size of the viewing window is 205x260 mm Weight 60 kg Power consumption 3.5 kW
Produced in: Tomsk
Functional signal generator G6-50
Functional signal generator G6-50
Technical specifications: The waveform is sinusoidal, meander, triangular, sawtooth, (straight, reverse), offset, rectangular (TTL) Frequency range from 0.1 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min The amplitude of the signal is sinusoidal ± 5 V at a load of 600 ohms of the form ± 10 V without load Signal span: meander, triangular, ± 10 V at 600 ohm load sawtooth (forward, reverse) ±20 V without load Limits of output signal level adjustment: -sinusoidal shape from 4 mV to 3.7 V (skz) at a load of 600 ohms from 8 mV to 7.4 V (scz) without load -meander, triangular, sawtooth from 10 mV to 10.465 V (span) at a load of 600 ohms shape: from 20 mV to 20.93 V (span) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz sinusoidal shape relative to ± 2% at frequencies from 10 Hz to 200 kHz 1 kHz ±5% at frequencies from 200 kHz to 2 MHz The harmonic coefficient of the sinusoidal ± 0.2% at frequencies from 10 to 100 Hz forms ± 0.07% at frequencies from 100 Hz to 10 kHz ±2% at frequencies from 10 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns in the frequency range from 0.1 Hz to 2 MHz Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Multifunctional vibration measuring complex MVK-32
Multifunctional vibration measuring complex MVK-32
Designed for: measurements (along with the primary measuring transducers of PIP) of vibroacoustic characteristics according to specified algorithms during complex monitoring of buildings, structures and mechanisms.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region
Meter recorder IS-203.3
Meter recorder IS-203.3
from 34 431 ₽
The IS-203.3 meter-recorder is designed to measure and convert analog signals from primary converters (temperature, pressure, humidity, etc.) into the value of the measured physical quantity, as well as to register measuring information in the device's memory and then transfer it to a computer (RS 485 or USB) for visualization in the form of tables and graphs. The meter recorder is a microprocessor-based meter equipped with a non-volatile storage device and a real-time clock. The device has the ability to work as a network device (up to 20 network devices at the same time) or stand-alone with subsequent connection to computers (laptop) for reading data. The operating conditions of the meter IS-203.3 Ambient temperature, °C: -30...+50. Relative humidity, %: up to 90. Atmospheric pressure, kPa: 70...106.7.
Produced in: Kolomna, Moscow region
Smart probe of relative humidity and temperature L=1000 mm SSVL.1000
Smart probe of relative humidity and temperature L=1000 mm SSVL.1000
from 16 560 ₽
The smart probe of relative humidity and temperature L=1000 mm SSVL.1000 is designed to measure the temperature of gaseous materials without mechanical impurities and aggressive vapors, relative humidity by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor based on the Android program. Operating conditions of the SZVL.1000 smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the smart probe SSVL.1000 Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor based on the Android program. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor based on the Android program. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
Appointment: continuous pumping of atmospheric air with a constant flow rate through a filter element based on Petryanova fabric. measurement of ionizing radiation parameters at a controlled point in accordance with the capabilities of the unit used.
Doza
Zelenograd
Produced in: Moscow