Search

3964 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Applying
    Loading...
  • 552
    Names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 108
    Additional
    Loading...
View:
3964 products
High wall table LAB-PRO SPCv 120.80.90 LA
High wall table LAB-PRO SPCv 120.80.90 LA
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Basket VT25-K
Basket VT25-K
It is intended for placement in the inner bath of the liquid thermostat VT25 or VT25-2 forms with samples when testing grouting cements in accordance with the State Standard 26798.2. Ventilation openings are nedeed for better convection of the coolant. Internal dimensions 290x250x140 mm Weight 2.5 kg
Produced in: Tomsk
Microphone condenser capsule MK-265
Microphone condenser capsule MK-265
It is designed to measure sound pressure in the air and is used in noise measuring equipment as a measuring transducer of infrasound, sound and ultrasonic pressure.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
VOLTAMMETER PARMA VAF-A(M2)
VOLTAMMETER PARMA VAF-A(M2)
It will help relay protection and automation services, the chief power engineer of industrial enterprises and a wide range of specialists engaged in setting up, monitoring, diagnostics and operation of electrical installations to solve the following tasks: − control phase alternation − remove the voltage characteristics − measure phase shift angles and build vector diagrams of voltage and current − control the circuits in the SHPT − check the integrity of electrical conductors − carry out operational maintenance of relay protection circuits and power circuits of electrical installations − monitor the condition and diagnose DC circuits − carry out phasing when setting up differential protection and connecting current and voltage transformers, electric motors − check the correct connection of electricity meters − determine the harmonic composition of current and voltage (up to and including the 19th harmonic)
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Vacuum tube MiniMed with K2-EDTA, 3 ml, 13×100mm, purple, glass, pack of 100 pcs
Vacuum tube MiniMed with K2-EDTA, 3 ml, 13×100mm, purple, glass, pack of 100 pcs
from 988 ₽
The potassium salt of ethylenediaminetetraacetic acid (EDTA) is the preferred anticoagulant for hematological studies. Material for research............... EDTA-blood, plasma Scope of application............................ hematological examination of whole blood
MiniMed
Suponevo
Produced in: Bryansk region
INSULATION PARAMETER METER PARMA TENSOR-2
INSULATION PARAMETER METER PARMA TENSOR-2
PARMA TENSOR-2 (AC bridge) is designed for automatic measurements of: · capacitance and tangent of the dielectric loss angle of high-voltage insulation of capacitors, inputs, transformers using an external high-voltage capacitor, both in laboratory and in the "field" conditions · effective values of the first harmonic of the current and voltage of the industrial frequency · the angle of phase shift between the signals supplied to the inputs of the device · network frequencies * Measurements can be carried out according to the "straight" and "inverse" (inverted) scheme. * Allocates the vector of the influence current, which makes it possible to dispense with the phase regulator of the test voltage source or devices for compensating the influence current.
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Rubidium frequency and time standards H1-1011/1
Rubidium frequency and time standards H1-1011/1
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The H1-1011 and H1-1011/2 standards include: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Muffle furnace LF-15/11-G1
Muffle furnace LF-15/11-G1
Design features: Durable ceramic muffle; Closed heaters on four sides of the chamber; Microprocessor temperature controller; Conveniently located control panel and bright LED display; Ease of management and control; LED indicators of heater operation and protection operation; Automatic shutdown of heating when opening the door; The door opens up and faces the user with the cold side; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than mm 525x655x680 Rated supply voltage, 220 V Rated power, W 6000
LOIP
Saint Petersburg
Produced in: Saint Petersburg
PARMA KMT TEMPERATURE MONITORING COMPLEX
PARMA KMT TEMPERATURE MONITORING COMPLEX
The temperature monitoring complex "PARMA KMT" is designed for: • implementation of continuous wireless multi-channel monitoring of temperatures of controlled objects and the environment • issuing alarms when the threshold values (setpoints) of dangerous and emergency overheating are reached by temperature and dangerous overheating rate • detection of temperature differences on the same type of connections • display of the measured temperature and the control point • transmission of telemetry data to top-level devices in automated control systems via Modbus protocol for processing, archiving and analysis of measurements • archiving, displaying and analyzing data, identifying trends and developing defects at the PS, RES level based on the proposed parameterized SCADA The temperature monitoring complex "PARMA KMT" is installed in switchgears (RC) with a voltage from 0.4 to 35 kV in the places of movable contacts, busbars, transformer inputs, cables and their connections with busbars.
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace MIMP-3P (desktop version)
Muffle furnace MIMP-3P (desktop version)
The furnace can be used as a universal laboratory muffle furnace in metallurgical, jewelry and ceramic production, in orthopedic dentistry, chemical and food laboratories. Technical specifications The furnace operates at ambient temperatures from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. The designation of the furnace when ordering: muffle furnace MIMP-75P, where 75 indicates the volume of the furnace working chamber in liters. Power consumption – 2500 W Dimensions of the working chamber WxDxH- 155x200×105 mm Dimensions WxDxH- 420x450x480 mm Weight – 30* kg (* - with control unit)
MIUS
Tula
Produced in: Tula
High laboratory work table LAB-PRO SLv 120.65.90 TR
High laboratory work table LAB-PRO SLv 120.65.90 TR
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg