VAC-32 platform scales
VAC-32 platform scales
from 69 990 ₽
Technical specifications: NIP, kg32 Discreteness, g1,0 External calibration Size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 20kg incl. ±1.0; sv.20kg to 32kg incl.± 1.5 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustmen 10kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-2100T
Technical laboratory scales VLTE-2100T
from 27 490 ₽
Technical characteristics: NIP, G2100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2KGF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-223S
Laboratory scales VLE-223S
from 107 490 ₽
Technical characteristics: NIP, G220 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm108x105 The smallest weighing limit, g0.02 The price of the calibration division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 220g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 3 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-410S
Laboratory scales VLTE-410S
from 74 990 ₽
Technical characteristics: NIP, G410 Discreteness, g 0.001 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the scale verification division, mg10 The limits of the permissible error during the initial verification, mgot 0.02 g to 50 g inclusive. ± 5; sv. 50 g to 200 g included. ±10; sv. 200 g to 410 g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
VL-224 comparator scales
VL-224 comparator scales
from 139 990 ₽
Technical specifications NIP, g220 Discreteness, g0,0001 External calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv 200 to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The setting time, seconds, no more-fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.0 wWeight adjustment 200gE2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-120C-O
Analytical scales VLA-120C-O
from 244 990 ₽
Technical specifications: NIP, g120 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of the permissible error of the scales during verification, ± mg, weighing intervals: from 0.01 g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, not more than 7 Adjusted weights 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VLA-220S-O
Analytical scales VLA-220S-O
from 269 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration, self-calibration Diameter of the scale bowl, mm91 The smallest weighing limit, g0.01 The price of the verification division, mg1 Limits of permissible error of the scales during verification, ± mg, in weighing intervals:from 0.01g to 50g incl. ±0.5; sv. 50g to 200g incl. ±1.0; sv. 200g to 220g incl. ±1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, s, no more than ~ 1.5 Overall dimensions of the scales, mm367x212x345 Weight of the scales, kg, no more than 7 The alignment weight is built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-224V-S
Analytical scales VL-224V-S
from 154 990 ₽
Technical characteristics: NIP, G220 Discreteness, g0,0001 Calibration,self-calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification scale division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ±1.0; sv 200 to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 Adjustment weight built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-6100S
Laboratory scales VLTE-6100S
from 49 990 ₽
Technical characteristics: NIP, G6100 Discreteness, g0,1 Self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during initial verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 6100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Adjustment weight is built-in The setting time, s, no more than~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-12 platform scales
RUNWAY-12 platform scales
from 69 990 ₽
Technical characteristics: NIP, kg12 Discreteness, g0.5/(0.2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 12 kg ± 1.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210/510
Laboratory scales VLTE-210/510
from 57 490 ₽
Technical specifications: NIP, g210/510 Discreteness, g0,001/0,01 External calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02/0.5 The price of the verification scale division, mg10/100 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5/±50; St. 50g to 200g incl. ±10/±50; St. 200g to 210g incl. ±15/±50; St. 210g to 500g incl. ±50; sv. 500g to 510g incl. ±100 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high The setting time, s, no more than ~3 /~2 Weight adjustment 200gF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-150S
Laboratory scales VLTE-150S
from 52 490 ₽
Technical characteristics: NIP, G150 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 150g incl. ±10 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg