Search

3939 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • 24
    Areas of use
    Loading...
  • 549
    Item names
    Loading...
  • 132
    Manufacturer
    Loading...
  • 59
    Made in
    Loading...
  • 109
    Additional
    Loading...
View:
3939 products
LB62 Laboratory bath
LB62 Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Six workstations with a diameter of 110 mm with five steel O-rings. Stamped steel tub with a volume of 19 liters and a depth of 110 mm. Bath volume 19 l Overall dimensions 560x370x410 mm The open part of the bath is 500x290 mm Bath depth 110 mm Weight 13.5 kg Power consumption 2.5 kW
Produced in: Tomsk
Cylinder d/hydrometers 3-31/220, pack of 5 pcs,
Cylinder d/hydrometers 3-31/220, pack of 5 pcs,
from 115 ₽
Designed for hydrometry. Without a scale. Made of glass HS1 according to GOST 21400-75.TU 4320-012-29508133-2009
MiniMed
Suponevo
Produced in: Bryansk region
ZVpP-100 Pneumatic Vacuum Shutter
ZVpP-100 Pneumatic Vacuum Shutter
The ZVpP-100 vacuum valve with pneumatic actuator equipped with 100mm conditional passages is designed to overlap vacuum systems in the pressure range from 1x10-6 to 1,07x105 Pa (from 0,75x10-8 to 800 mm Hg). The ZVpP-100 vacuum pneumatic shutter is manufactured in the climatic version of the UHL placement category 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69. The working environment is air and non–aggressive gases. The temperature of the working environment is from plus 1°C to plus 40°C. The vacuum valve with a pneumatic actuator is not intended for use in fire and explosive hazardous industries. The ZVpP-100 vacuum pneumatic shutter consists of a mechanism, a housing and a pneumatic actuator. The pneumatic actuator includes a pneumatic cylinder, on the piston of which a permanent magnet is installed to determine its position by means of magnetic position sensors "Closed" and "Open" fixed on the cylinder body and a distributor into which compressed air is supplied through a fitting. The speed of the pneumatic cylinder in particular and the operation of the shutter as a whole are regulated by rotating the pneumatic throttle head, if the pneumatic throttle heads are fully tightened, then the speed of opening and closing the shutter will be maximum. The solenoid, powered by a connector, serves as a distributor control device and is applicable in standard production conditions where the relative humidity of the air is not higher than 75%.
Produced in: Kazan
AK-1000 Acoustic calibrator
AK-1000 Acoustic calibrator
characteristics The AK-1000 is recommended for use with OCTAVE-101A, OCTAVE-101AM, OCTAVE-110A, OCTAVE-110A-ECO, OCTAVE-121, OCTAPHONE-110, OCTAVE-201, ECOPHYSICS-110A sound meters. The AK-1000 can be used for calibration of acoustic measuring paths with VMK-205, MK-265, MR-201, M-201, MK-233 microphones, and other ½-inch microphones. technical specifications Reproducible ultrasound, dB (rel. 20 µPa): 94 and 114 The limits of the permissible basic error of the reproducible ultrasound, dB: ± 0.25 Limits of the permissible additional error of the ultrasound caused by a change in ambient temperature in the operating temperature range, dB: ± 0.08 Frequency of the reproduced sound pressure, Hz: 1000 Limits of the permissible basic relative error of reproduction of the sound pressure frequency, %: ± 0.7 Limits of the permissible additional relative error of the sound pressure frequency caused by a change in ambient temperature in the operating temperature range, %: ± 0.07 Coefficient of nonlinear distortion, %, not more than: 2.5 Weight (with batteries), kg, no more than: 0.250 Overall dimensions (length×diameter), mm, no more: 158×35 Operating conditions: - ambient temperature, ° C: from minus 10 to 50 - relative humidity (at 40 ° C), %, not more than: 90 - atmospheric pressure, kPa: from 65 to 108
Produced in: Moscow
Industrial drying cabinet SNOL-750
Industrial drying cabinet SNOL-750
from 1 267 696 ₽
The industrial drying cabinet is designed for drying, tempering, aging, thermal testing and other types of heat treatment of various materials in an air environment at temperatures up to 350 (optionally up to 500) ° C with forced air convection in stationary conditions.
Produced in: Tula
Continuous measurement of temperature in the industrial area
Continuous measurement of temperature in the industrial area
Appointment: the continuous measurement system allows for continuous measurement of the heating temperature of the industrial bucket, to improve the stability and reliability of measuring the temperature of liquid metal. Due to the fixed measurement position, the system eliminates errors due to the human factor. This method of measuring temperature was researched and invented on the theory of an absolutely black body. The principle of the temperature measurement system is the immersion of a temperature probe into molten steel to determine the temperature. The temperature probe made of an absolutely black body is designed in a special way to receive an infrared radiation signal corresponding to the temperature of molten steel. Scope of application: Intermediate bucket Measuring range: Warming up the promkovsh: from 800°C to 1400°C; Molten steel: from 1400°C to 1600°C Accuracy: Preheating of the promkovsh 7 ° C; Molten steel: 3 ° C Response time: Hot response time 75 sec; Cold response time 4 min Measuring probe length: 964mm, 1100mm Durability of measuring probes: 12 hours, 24 hours, 48 hours Number of thermal shocks: up to 5 times
Produced in: Lipetsk
Vacuum tube MiniMed without filler, 3 ml, 13×75 mm, red, glass, pack.100 pcs
Vacuum tube MiniMed without filler, 3 ml, 13×75 mm, red, glass, pack.100 pcs
from 1 143 ₽
Tubes without fillers are used for the study of blood serum in biochemical, immunological and serological tests. Material for research............... blood serum Scope of application............................ blood serum research in biochemistry, immunology, serology Centrifugation................................ 1000 - 1500 g - 10 minutes
MiniMed
Suponevo
Produced in: Bryansk region
Wall-mounted low table LAB-PRO SPKn 120.80.75 SS
Wall-mounted low table LAB-PRO SPKn 120.80.75 SS
Combined working surface: STEEL main table top (single stainless steel module with anti-spill side) with a depth of 650 mm / auxiliary table top made of TRESPA material with a depth of 150 mm Length, mm: 1200 Depth, mm: 800 Height, mm: 750 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet LAB-1200 ballscrews
Exhaust cabinet LAB-1200 ballscrews
Working surface: Porcelain stoneware (ceramic tile 300*300mm) Length, mm: 1232 Depth, mm: 925 Height, mm: 2100 equipment Working box the side and back panels are lined with a row of ceramic tiles to a height of 400mm the case is melamine with a thickness of 16mm lifting screen with the possibility of fixing at any height – organic acrylic glass with a thickness of 8mm, lifting 0–750mm, increases the height of the cabinet with a full lift by 430mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted high table LAB-PRO SPKv 90.80.90 KG
Wall-mounted high table LAB-PRO SPKv 90.80.90 KG
Combined work surface: main countertop - KG (porcelain stoneware), 650 mm deep / auxiliary countertop made of TRESPA material with a depth of 150 mm Length, mm: 900 Depth, mm: 800 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Automatic device for determining the flash point in a closed crucible TVZ-LAB-12
Automatic device for determining the flash point in a closed crucible TVZ-LAB-12
The TVZ-LAB-12 automatic apparatus is designed to determine the flash point in a closed crucible by the Pensky-Martens method in accordance with GOST R EN ISO 2719-2008, GOST R 54279-2010, GOST ISO 2719-2013, GOST 6356-75, GOST 9287-59, ISO 2719, ASTM D 93 (methods A, B and C). The device is designed taking into account all the requirements of the new GOST R EN ISO 2719-2008 for testing. Extensive software configuration options and a special design of the device ignition device allows you to obtain test results with high convergence in GSO even when using electric ignition according to GOST R EN ISO 2719-2008. Technical specifications: Flash temperature measurement range 0 ... 400°C Heating speed 0.5 ... 20°/min The range of setting the ignition period, 0.5 ... 10°C Igniting gas flame, electric spiral Flash sensor Thermocouple with low mass The rotation speed of the agitator is 30 ... 250 rpm Power consumption from AC 220V, no more than 600 watts Overall dimensions 465x340x390 mm The weight of the device is 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg